The contamination of DEHP on the surfaces of PVC sheet and risk of infants

被引:2
作者
Kim, Hyuntae [1 ]
Kim, Taewoo [2 ]
Tanabe, Shin-Ichi [3 ]
机构
[1] Yamaguchi Univ, Grad Sch Sci & Technol Innovat, Yamaguchi, Japan
[2] EBS Environm Bldg Safety E&C, Seoul, South Korea
[3] Waseda Univ, Dept Architecture, Tokyo, Japan
关键词
DEHP; SVOCs; plasticizer; PVC flooring; bleed-out; SEMIVOLATILE ORGANIC-COMPOUNDS; IN-HOUSE DUST; INDOOR AIR; HUMAN HEALTH; EXPOSURE; ASSOCIATION; PHTHALATE; ASTHMA; TOXICOLOGY; CHILDREN;
D O I
10.1080/13467581.2022.2032083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study conducted laboratory tests and field surveys to understand the plasticizer contamination characteristics on the surface of PVC flooring materials used indoors, and discussed the risk of exposure of plasticizers to infants indoors. A lab experiment was conducted to measure the bleed-out of DEHP on PVC sheet surfaces. As a result of the bleed-out, the amount of DEHP on the specimen surfaces was 432 to 880 [ug/m(2)]. The present study showed that plasticizers such as DEHP contained in the PVC sheet accumulate a significant amount of DEHP on the surface of the PVC sheet even if a material such as house dust is not present on the surface of the PVC sheet. In addition, this study found that even if the dust accumulated on the PVC floor surface was vacuumed, it was difficult to completely remove the DEHP accumulated on the floor surface. The field surveys showed that the average concentration of DEHP on the floor surface in Korean and Japanese house were 356 and 608 ug/m(2) respectively. Since infants have behavioral characteristics of crawling, sitting, and lying on the floor, they have more opportunities to directly contact the floor than adults.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 42 条
  • [1] Phthalates in house dust
    Abb, M.
    Heinrich, T.
    Sorkau, E.
    Lorenz, W.
    [J]. ENVIRONMENT INTERNATIONAL, 2009, 35 (06) : 965 - 970
  • [2] [Anonymous], 1999, Guidelines for Air Quality
  • [3] Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study
    Bergh, C.
    Torgrip, R.
    Emenius, G.
    Ostman, C.
    [J]. INDOOR AIR, 2011, 21 (01) : 67 - 76
  • [4] Quantitative assessments of indoor air pollution and respiratory health in a population-based sample of French dwellings
    Billionnet, Cecile
    Gay, Emilie
    Kirchner, Severine
    Leynaert, Benedicte
    Annesi-Maesano, Isabella
    [J]. ENVIRONMENTAL RESEARCH, 2011, 111 (03) : 425 - 434
  • [5] European indoor air quality audit project in 56 office buildings
    Bluyssen, PM
    Fernandes, ED
    Groes, L
    Clausen, G
    Fanger, PO
    Valbjorn, O
    Bernhard, CA
    Roulet, CA
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (04): : 221 - 238
  • [6] Health ranking of ingested semi-volatile organic compounds in house dust: an application to France
    Bonvallot, N.
    Mandin, C.
    Mercier, F.
    Le Bot, B.
    Glorennec, P.
    [J]. INDOOR AIR, 2010, 20 (06) : 458 - 472
  • [7] Phthalates in indoor dust and their association with building characteristics
    Bornehag, CG
    Lundgren, B
    Weschler, CJ
    Sigsgaard, T
    Hagerhed-Engman, L
    Sundell, J
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (10) : 1399 - 1404
  • [8] The association between asthma and allergic symptoms in children and phthalates in house dust:: A nested case-control study
    Bornehag, CG
    Sundell, J
    Weschler, CJ
    Sigsgaard, T
    Lundgren, B
    Hasselgren, M
    Hägerhed-Engman, L
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (14) : 1393 - 1397
  • [9] Emission of Di-2-ethylhexyl phthalate from PVC flooring into air and uptake in dust: Emission and sorption experiments in FLEC and CLIMPAQ
    Clausen, PA
    Hansen, V
    Gunnarsen, L
    Afshari, A
    Wolkoff, P
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (09) : 2531 - 2537
  • [10] CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227