Multiwall Carbon Nanotubes/Spherical Glassy Carbon as Environmentally Friendly Adsorption Materials Utilized in Adsorptive Stripping Voltammetry for the Determination of Trace Amounts of Ga(III)

被引:1
|
作者
Grabarczyk, Malgorzata [1 ]
Fialek, Marzena [1 ]
Wlazlowska, Edyta [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Inst Chem Sci, Dept Analyt Chem, PL-20031 Lublin, Poland
关键词
multiwall carbon nanotubes; spherical glassy carbon; lead film electrode; adsorptive stripping voltammetry; eco-friendly detection of gallium; environmental water samples; GALLIUM; NANOTUBES; MOLYBDENUM; ELECTRODE; COMPLEX;
D O I
10.3390/ma17040966
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This work presents a proposal for an adsorptive stripping voltammetric (AdSV) method for gallium(III) determination at an eco-friendly multiwall carbon nanotube/spherical glassy carbon (MWCNT/SGC) electrode modified with a lead film. The operational factors influencing the sensitivity of the AdSV procedure were thoroughly investigated, and their most favorable values were chosen (0.1 mol L-1 acetate buffer solution pH = 5.6; 7 x 10(-5) mol L-1 Pb(II); 2 x 10(-4) mol L-1 cupferron; potential/time of lead film formation: -1.9 V/30 s; potential/time of Ga(III)-cupferron adsorption: -0.75 V/30 s). The newly developed MWCNT/SGCE has proven to be a competitive substrate to the glassy carbon electrode to create a lead film electrode, since it allows the determination of gallium in a wider range of concentrations from 3 x 10(-9) to 4 x 10(-7) mol L-1 with a lower limit of detection equal to 9.5 x 10(-10) mol L-1. The elaborated procedure has been shown to be highly selective and insensitive to the presence of an even 100-fold excess of most of the ions commonly found in environmental waters. The MWCNT/SGC sensor, which can maintain >95% of its original response after 70 days of use, has been successfully applied for the detection of gallium in water samples with the relative standard deviation (RSD) ranging from 4.5% to 6.2% (n = 3) and recoveries in the range from 95.3% to 104.9%.
引用
收藏
页数:13
相关论文
共 30 条
  • [21] Determination of lead(II) by adsorptive stripping voltammetry using a glassy carbon electrode modified with β-cyclodextrin and chemically reduced graphene oxide composite
    Zhan, Fengping
    Gao, Feng
    Wang, Xia
    Xie, Liqing
    Gao, Fei
    Wang, Qingxiang
    MICROCHIMICA ACTA, 2016, 183 (03) : 1169 - 1176
  • [22] The convenient determination of palladium at a solid electrode via adsorptive stripping voltammetry at a glassy carbon electrode modified with a random array of mercury nanodroplets
    Abinian, Poobalasingam
    Wildgoose, Gregory G.
    Xiao, Lei
    Compton, Richard G.
    ELECTROANALYSIS, 2008, 20 (14) : 1607 - 1609
  • [23] Determination of Sb(III) using an ex-situ bismuth screen-printed carbon electrode by adsorptive stripping voltammetry
    Rojas-Romo, Carlos
    Serrano, Nuria
    Arino, Cristina
    Arancibia, Veronica
    Manuel Diaz-Cruz, Jose
    Esteban, Miguel
    TALANTA, 2016, 155 : 21 - 27
  • [24] Simultaneous Determination of Vitamin E and Vitamin K in Food Supplements Using Adsorptive Stripping Square-Wave Voltammetry at Glassy Carbon Electrode
    Kastrati, Gylxhane
    Jashari, Granit
    Sys, Milan
    Svecova, Blanka
    Arbneshi, Tahir
    Metelka, Radovan
    Bilkova, Zuzana
    Korecka, Lucie
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [25] Determination of Carbendazim by Adsorptive Stripping Differential Pulse Voltammetry Employing Glassy Carbon Paste Electrode Modified with Graphene and Amberlite XAD 2 Resin
    Khare, Ninad G.
    Dar, Riyaz A.
    Srivastava, Ashwini K.
    ELECTROANALYSIS, 2015, 27 (08) : 1915 - 1924
  • [26] Determination of Trace Levels of Nickel(II) by Adsorptive Stripping Voltammetry Using a Disposable and Low-Cost Carbon Screen-Printed Electrode
    Padilla, Victor
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    CHEMOSENSORS, 2021, 9 (05)
  • [27] Determination of trace amount of lead(II) in sweet fruit-flavored powder drinks by differential pulse adsorptive stripping voltammetry at carbon paste electrode
    Gholivand, M. B.
    Malekian, M.
    ELECTROANALYSIS, 2008, 20 (04) : 367 - 373
  • [28] Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1-Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode
    Segura, Rodrigo A.
    Pizarro, Jaime A.
    Oyarzun, Maria P.
    Castillo, Alejandra D.
    Diaz, Karina J.
    Placencio, Alan B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1707 - 1719
  • [29] Simultaneous Electrochemical Preconcentration and Determination of Dopamine and Uric acid by Square-Wave Adsorptive Stripping Voltammetry using a Poly(Safranine O)-Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Arpaci, Rabia Bozdogan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (06): : 2775 - 2789
  • [30] Dual-signal anodic stripping voltammetric determination of trace arsenic(III) at a glassy carbon electrode modified with internal-electrolysis deposited gold nanoparticles
    Gu, Tiean
    Bu, Lijuan
    Huang, Zhao
    Liu, Yan
    Tang, Zhiyong
    Liu, Ying
    Huang, Siyu
    Xie, Qingji
    Yao, Shouzhuo
    Tu, Xinman
    Luo, Xubiao
    Luo, Shenglian
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 33 : 43 - 46