Cervical length screening for predicting preterm birth: A comparative review of guidelines

被引:6
|
作者
Oglou, Mechmet Impis [1 ]
Tsakiridis, Ioannis [1 ]
Mamopoulos, Apostolos [1 ]
Kalogiannidis, Ioannis [1 ]
Athanasiadis, Apostolos [1 ]
Dagklis, Themistoklis [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Obstet & Gynaecol 3, Konstantinoupoleos 49, Thessaloniki 54642, Greece
关键词
cervical length; guidelines; prediction; preterm labor; screening; PRIOR CONE BIOPSY; TWIN PREGNANCIES; SONOGRAPHIC MEASUREMENT; TRANSVAGINAL ULTRASONOGRAPHY; SINGLETON PREGNANCY; INCREASED RISK; WOMEN; PREVENTION; METAANALYSIS; LEVEL;
D O I
10.1002/jcu.23354
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A cervical length (CL) assessment may predict preterm birth (PTB). This study aimed to analyze and compare the recommendations of guidelines on the role of CL in the prediction of PTB. There is no consensus regarding universal screening of asymptomatic women without a history of prior spontaneous PTB (sPTB), using CL. On the other hand, CL assessment is recommended in cases with a history of sPTB due to the high recurrence rate. Finally, there is discrepancy regarding CL assessment in asymptomatic women with multiple pregnancy. Although far from perfect, CL measurement remains the best available method to predict PTB.
引用
收藏
页码:472 / 478
页数:7
相关论文
共 50 条
  • [1] Predicting preterm birth: Cervical length and fetal fibronectin
    Son, Moeun
    Miller, Emily S.
    SEMINARS IN PERINATOLOGY, 2017, 41 (08) : 445 - 451
  • [2] The introduction of a universal transvaginal cervical length screening program is associated with a reduced preterm birth rate
    Figarella, Aude
    Chau, Cecile
    Loundou, Anderson
    d'Ercole, Claude
    Bretelle, Florence
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (02) : 219.e1 - 219.e14
  • [3] Cervical length as a screening tool for preterm birth in twin pregnancies: a systematic review and critical evaluation of quality clinical practice guidelines
    De Vito, Marika
    Cetraro, Jessica
    Capannolo, Giulia
    Alameddine, Sara
    Patelli, Chiara
    D'Antonio, Francesco
    Rizzo, Giuseppe
    JOURNAL OF PERINATAL MEDICINE, 2024, 52 (03) : 262 - 269
  • [4] Is universal screening for cervical length among singleton pregnancies with no history of preterm birth justified?
    Rozenberg, P.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2016, 45 (10): : 1337 - 1345
  • [5] Improving the screening accuracy for preterm labor: is the combination of fetal fibronectin and cervical length in symptomatic patients a useful predictor of preterm birth? A systematic review
    DeFranco, Emily A.
    Lewis, David F.
    Odibo, Anthony O.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 208 (03)
  • [6] Cervical length at mid-gestation in screening for preterm birth in twin pregnancy
    Pagani, G.
    Stagnati, V.
    Fichera, A.
    Prefumo, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 48 (01) : 56 - 60
  • [7] Gestational age at cervical length measurement and preterm birth in twins
    Ehsanipoor, R. M.
    Haydon, M. L.
    Gaffaney, C. Lyons
    Jolley, J. A.
    Petersen, R.
    Lagrew, D. C.
    Wing, D. A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (01) : 81 - 86
  • [8] PREDICTION OF PRETERM BIRTH - CERVICAL LENGTH AND BIOMARKERS
    Gregor, Miroslav
    AKTUALNI GYNEKOLOGIE A PORODNICTVI, 2020, 12 : 20 - 24
  • [9] Screening for spontaneous preterm birth by cervical length and shear-wave elastography in the first trimester of pregnancy
    Feng, Qiaoli
    Chaemsaithong, Piya
    Duan, Honglei
    Ju, Xiaoqing
    Appiah, Kubi
    Shen, Lixia
    Wang, Xueqin
    Tai, Yiyun
    Leung, Tak Yeung
    Poon, Liona C.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 227 (03)
  • [10] Predicting preterm birth in women with previous preterm birth and cervical length ≥ 25 mm
    Care, A. G.
    Sharp, A. N.
    Lane, S.
    Roberts, D.
    Watkins, L.
    Alfirevic, Z.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (06) : 681 - 686