Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty

被引:6
|
作者
Pitz-Goncalves, Lauren I. [1 ]
Deckard, Evan R. [2 ]
Meneghini, R. Michael [2 ,3 ]
机构
[1] Univ Chicago, Dept Orthopaed Surg & Rehabil Serv, Chicago, IL USA
[2] Indiana Joint Replacement Inst, Indianapolis, IN USA
[3] Indiana Univ Sch Med, Dept Orthopaed Surg, Indianapolis, IN USA
关键词
total hip arthroplasty; large head; dislocation; instability; posterior approach; DIRECT ANTERIOR APPROACH; RANDOMIZED CLINICAL-TRIAL; METAL-ION LEVELS; FOLLOW-UP; PREVENT DISLOCATION; RISK-FACTOR; SAFE ZONE; REVISION; WEAR; SIZE;
D O I
10.1016/j.arth.2023.02.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. Methods: Atotal of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. Results: The overall dislocation rate was 0.98%. Use of femoral head sizes >= 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P =.279). Also, no dislocations occurred in patients who had dual-mobility bearings or >= 40-millimeter femoral heads (P =.007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P =.013). Thirteen of 14 dislocations were in women (P =.005). Conclusion: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. Level of Evidence: IVeconsecutive case series; no control group. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S124 / S130
页数:7
相关论文
共 50 条
  • [21] In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis
    Homma, Yasuhiro
    Baba, Tomonori
    Ozaki, Yu
    Watari, Taiji
    Kobayashi, Hideo
    Ochi, Hironori
    Matsumoto, Mikio
    Kaneko, Kazuo
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 491 - 497
  • [22] Intraprosthetic Dislocation of a Modular Dual-Mobility Total Hip Arthroplasty With Posterior Migration of the Polyethylene Liner
    Cantrell, Austin J.
    Forrester, D. Alex
    Crawford, Alexander W.
    Morris, Cade
    Thakral, Rishi
    ARTHROPLASTY TODAY, 2024, 25
  • [23] The Use of Dual-mobility Components in Total Hip Arthroplasty
    Lachiewicz, Paul F.
    Watters, Tyler Steven
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (08) : 481 - 486
  • [24] The use of a dual-mobility concept in total hip arthroplasty patients with spastic disorders
    Sanders, Rick J. M.
    Swierstra, Bart A.
    Goosen, Jon H. M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 1011 - 1016
  • [25] Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head
    Assi, Chahine
    Kheir, Nadim
    Samaha, Camille
    Kouyoumjian, Pascal
    Yammine, Kaissar
    SICOT-J, 2018, 4
  • [26] Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options
    Zagra, Luigi
    Caboni, Eleonora
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 661 - 668
  • [27] Primary total hip arthroplasty: mid-term outcomes of dual-mobility cups in patients at high risk of dislocation
    Assi, Chahine
    Barakat, Hanane
    Mansour, Jad
    Samaha, Camille
    Yammine, Kaissar
    HIP INTERNATIONAL, 2021, 31 (02) : 174 - 180
  • [28] Cementless dual-mobility cup in total hip arthroplasty revision
    Jean Louis Prudhon
    François Steffann
    André Ferreira
    Régis Verdier
    Thierry Aslanian
    Jacques Caton
    International Orthopaedics, 2014, 38 : 2463 - 2468
  • [29] In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis
    Yasuhiro Homma
    Tomonori Baba
    Yu Ozaki
    Taiji Watari
    Hideo Kobayashi
    Hironori Ochi
    Mikio Matsumoto
    Kazuo Kaneko
    International Orthopaedics, 2017, 41 : 491 - 497
  • [30] Cementless dual-mobility cup in total hip arthroplasty revision
    Prudhon, Jean Louis
    Steffann, Francois
    Ferreira, Andre
    Verdier, Regis
    Aslanian, Thierry
    Caton, Jacques
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (12) : 2463 - 2468