Accuracy of low-cost alternative facial scanners: a prospective cohort study

被引:10
作者
Bartella, Alexander K. [1 ]
Laser, Josefine [1 ]
Kamal, Mohammad [2 ]
Krause, Matthias [1 ]
Neuhaus, Michael [1 ]
Pausch, Niels C. [1 ]
Sander, Anna K. [1 ]
Lethaus, Bernd [1 ]
Zimmerer, Rudiger [1 ]
机构
[1] Univ Leipzig, Dept Oral & Maxillofacial Surg, Liebigstr 12, D-04103 Leipzig, Germany
[2] Kuwait Univ, Fac Dent, Dept Surg Sci, Safat, Kuwait
来源
ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG | 2023年 / 27卷 / 01期
关键词
Face scan; Three-dimensional face scan; Photogrammetry; Smart device; iPhone; SYSTEM; MOBILE;
D O I
10.1007/s10006-022-01050-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Three-dimensional facial scans have recently begun to play an increasingly important role in the peri-therapeutic management of oral and maxillofacial and head and neck surgery cases. Face scan images can be generated by optical facial scanners utilizing line-laser, stereophotography, or structured light modalities, as well as from volumetric data: for example, from cone beam computed tomography (CBCT). This study aimed to evaluate whether two low-cost procedures for the creation of three-dimensional face scan images were capable of producing sufficiently accurate data sets for clinical analysis. Materials and methods Fifty healthy volunteers were included in the study. Two test objects with defined dimensions (Lego bricks) were attached to the forehead and the left cheek of each volunteer. Facial anthropometric values (i.e., the distances between the medial canthi, the lateral canthi, the nasal alae, and the angles of the mouth) were first measured manually. Subsequently, face scans were performed with a smart device and manual photogrammetry and the values obtained were compared with the manually measured data sets. Results The anthropometric distances deviated, on average, 2.17 mm from the manual measurements (smart device scanning deviation 3.01 mm, photogrammetry deviation 1.34 mm), with seven out of eight deviations being statistically significant. For the Lego brick, from a total of 32 angles, 19 values demonstrated a significant difference from the original 90 degrees angles. The average deviation was 6.5 degrees (smart device scanning deviation 10.1 degrees, photogrammetry deviation 2.8 degrees). Conclusion Manual photogrammetry demonstrated greater accuracy when creating three-dimensional face scan images; however, smart devices are more user-friendly. Dental professionals should monitor camera and smart device technical improvements carefully when choosing and adequate technique for 3D scanning.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 11 条
  • [1] The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
  • [2] Validation of the Vectra H1 portable three-dimensional photogrammetry system for facial imaging
    Camison, L.
    Bykowski, M.
    Lee, W. W.
    Carlson, J. C.
    Roosenboom, J.
    Goldstein, J. A.
    Losee, J. E.
    Weinberg, S. M.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (03) : 403 - 410
  • [3] Customised design and manufacture of protective face masks combining a practitioner-friendly modelling approach and low-cost devices for digitising and additive manufacturing This paper analyses the viability of replacing conventional practice with AM method to make customized protective face masks
    Cazon, Aitor
    Aizpurua, Jon
    Paterson, Abby
    Bibb, Richard
    Campbell, R. Ian
    [J]. VIRTUAL AND PHYSICAL PROTOTYPING, 2014, 9 (04) : 251 - 261
  • [4] Comparison of three-dimensional scanner systems for craniomaxillofacial imaging
    Knoops, Paul G. M.
    Beaumont, Caroline A. A.
    Borghi, Alessandro
    Rodriguez-Florez, Naiara
    Breakey, Richard W. F.
    Rodgers, William
    Angullia, Freida
    Jeelani, N. U. Owase
    Schievano, Silvia
    Dunaway, David J.
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (04) : 441 - 449
  • [5] Three-Dimensional Surface Imaging and the Continuous Evolution of Preoperative and Postoperative Assessment in Rhinoplasty
    Lekakis, Garyfalia
    Claes, Peter
    Hamilton, Grant S., III
    Hellings, P. W.
    [J]. FACIAL PLASTIC SURGERY, 2016, 32 (01) : 88 - 94
  • [6] Luhmann T., 2010, Nahbereichsphotogrammetrie: Grundlagen, Methoden und Anwendungen
  • [7] Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning
    Modabber, Ali
    Peters, Florian
    Kniha, Kristian
    Goloborodko, Evgeny
    Ghassemi, Alireza
    Lethaus, Bernd
    Hoelzle, Frank
    Moehlhenrich, Stephan Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) : 1719 - 1724
  • [8] Peters F, 2016, INT J COMPUT DENT, V19, P217
  • [9] Steiner TRS., 2017, DEUT Z SPORTMED, V02, P43, DOI [10.5960/dzsm.2017.270, DOI 10.5960/DZSM.2017.270]
  • [10] Comparison of three-dimensional surface-imaging systems
    Tzou, Chieh-Han John
    Artner, Nicole M.
    Pona, Igor
    Hold, Alina
    Placheta, Eva
    Kropatsch, Walter G.
    Frey, Manfred
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2014, 67 (04) : 489 - 497