Non-invasive imaging of pathological scars using a portable handheld two-photon microscope

被引:1
作者
Han, Yang [1 ,2 ]
Sun, Yuxuan [3 ]
Yang, Feili [4 ]
Liu, Qingwu [2 ]
Fei, Wenmin [5 ]
Qiu, Wenzhuo [6 ]
Wang, Junjie [7 ]
Li, Linshuang [8 ]
Zhang, Xuejun [9 ,10 ]
Wang, Aimin [11 ]
Cui, Yong [1 ,2 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Grad Sch, Beijing 100730, Peoples R China
[2] China Japan Friendship Hosp, Dept Dermatol, Beijing 100029, Peoples R China
[3] Peking Univ, Coll Engn, Beijing 100871, Peoples R China
[4] Peking Univ, Shenzhen Grad Sch, Sch Chem Biol & Biotechnol, State Key Lab Chem Oncogen, Shenzhen 518055, Guangdong, Peoples R China
[5] Nanchang Univ, Dept Dermatol, Affiliated Hosp 1, Nanchang 330006, Jiangxi, Peoples R China
[6] Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China
[7] Peking Univ, Coll Future Technol, Beijing 100871, Peoples R China
[8] Beijing Transcend Vivoscope Biotech, Beijing 100085, Peoples R China
[9] Anhui Med Univ, Affiliated Hosp 1, Dept Dermatol, Hefei 230001, Anhui, Peoples R China
[10] Anhui Med Univ, Inst Dermatol, Hefei 230001, Anhui, Peoples R China
[11] Peking Univ, Sch Elect, Beijing 100871, Peoples R China
关键词
Scars; Two-photon microscope; Two-photon excitation fluorescence; Second harmonic generation microscopy; In vivo; VIVO HUMAN SKIN; TOMOGRAPHY; RESOLUTION; KELOIDS;
D O I
10.1097/CM9.0000000000002715
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pathological scars are a disorder that can lead to various cosmetic, psychological, and functional problems, and no effective assessment methods are currently available. Assessment and treatment of pathological scars are based on cutaneous manifestations. A two-photon microscope (TPM) with the potential for real-time non-invasive assessment may help determine the under-surface pathophysiological conditions in vivo. This study used a portable handheld TPM to image epidermal cells and dermal collagen structures in pathological scars and normal skin in vivo to evaluate the effectiveness of treatment in scar patients. Methods: Fifteen patients with pathological scars and three healthy controls were recruited. Imaging was performed using a portable handheld TPM. Five indexes were extracted from two dimensional (2D) and three dimensional (3D) perspectives, including collagen depth, dermo-epidermal junction (DEJ) contour ratio, thickness, orientation, and occupation (proportion of collagen fibers in the field of view) of collagen. Two depth-dependent indexes were computed through the 3D second harmonic generation image and three morphology-related indexes from the 2D images. We assessed index differences between scar and normal skin and changes before and after treatment. Results: Pathological scars and normal skin differed markedly regarding the epidermal morphological structure and the spectral characteristics of collagen fibers. Five indexes were employed to distinguish between normal skin and scar tissue. Statistically significant differences were found in average depth (t = 9.917, P <0.001), thickness (t = 4.037, P <0.001), occupation (t = 2.169, P <0.050), orientation of collagen (t = 3.669, P <0.001), and the DEJ contour ratio (t = 5.105, P <0.001). Conclusions: Use of portable handheld TPM can distinguish collagen from skin tissues; thus, it is more suitable for scar imaging than reflectance confocal microscopy. Thus, a TPM may be an auxiliary tool for scar treatment selection and assessing treatment efficacy.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 50 条
  • [31] Miniaturized multimodal multiphoton microscope for simultaneous two-photon and three-photon imaging with a dual-wavelength Er-doped fiber laser
    Huang, Lin
    Zhou, Xin
    Liu, Qihao
    MacAulay, Calum E.
    Tang, Shuo
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (02): : 624 - 635
  • [32] Apertureless near-field/far-field CW two-photon microscope for biological and material imaging and spectroscopic applications
    Nowak, Derek B.
    Lawrence, A. J.
    Sanchez, Erik J.
    APPLIED OPTICS, 2010, 49 (35) : 6766 - 6771
  • [33] Parallel and Flexible Imaging using Two-photon RESOLFT Microscopy with Spatial Light Modulator Control
    Xue, Yi
    Rowlands, Christopher J.
    So, Peter T. C.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XV, 2015, 9329
  • [34] Fast two-layer two-photon imaging of neuronal cell populations using an electrically tunable lens
    Grewe, Benjamin F.
    Voigt, Fabian F.
    Van't Hoff, Marcel
    Helmchen, Fritjof
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07): : 2035 - 2046
  • [35] A non-invasive, bioimpedance-based 2-dimensional imaging system for detection and localization of pathological epithelial tissues
    Ching, Congo Tak-Shing
    Chen, Jhih-Hao
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 319 - 326
  • [36] Two-photon spectral fluorescence lifetime and second-harmonic generation imaging of the porcine cornea with a 12-femtosecond laser microscope
    Batista, Ana
    Breunig, Hans Georg
    Uchugonova, Aisada
    Morgado, Antonio Miguel
    Koenig, Karsten
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (03)
  • [37] Second harmonic imaging of plants tissues and cell implosion using two-photon process in ZnO nanoparticles
    Urban, Ben E.
    Neogi, Purnima B.
    Butler, Sween J.
    Fujita, Yasuhisa
    Neogi, Arup
    JOURNAL OF BIOPHOTONICS, 2012, 5 (03) : 283 - 291
  • [38] Two-Photon in vivo Imaging of Dendritic Spines in the Mouse Cortex Using a Thinned-skull Preparation
    Yu, Xinzhu
    Zuo, Yi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (87):
  • [39] Detection theory for accurate and non-invasive skin cancer diagnosis using dynamic thermal imaging
    Godoy, Sebastian E.
    Hayat, Majeed M.
    Ramirez, David A.
    Myers, Stephen A.
    Padilla, R. Steven
    Krishna, Sanjay
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (04): : 2301 - 2323
  • [40] Non-invasive and Non-destructive Characterization of Tissue Engineered Constructs Using Ultrasound Imaging Technologies: A Review
    Kim, Kang
    Wagner, William R.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (03) : 621 - 635