Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography

被引:7
|
作者
Sasaki, Ryo [1 ]
Niki, Yasuo [1 ,3 ]
Kaneda, Kazuya [1 ]
Yamada, Yoshitake [2 ]
Nagura, Takeo [1 ]
Nakamura, Masaya [1 ]
Jinzaki, Masahiro [2 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi Shinjuku, Tokyo 1608582, Japan
基金
日本学术振兴会;
关键词
Osteoarthritis; Upright CT; Tibial joint line; Three-dimensional evaluation; Varus alignment; KINEMATICALLY ALIGNED TKA; POSTERIOR TIBIAL SLOPE; ALIGNMENT; BIOMECHANICS; VARUS; ARTHROPLASTY; ASSOCIATION; GEOMETRY; AXIS;
D O I
10.1016/j.knee.2023.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Two-dimensional (2D) coronal joint line orientation on radiography under weight-bearing conditions has been widely used in evaluating knee osteoarthritis (OA). However, the effects of tibial rotation remain unknown. The present study aimed to newly define three-dimensional (3D) joint surface orientation relative to the floor as an unchangeable 3D angle unaffected by tibial rotation using upright computed tomography (CT), and to investigate correlations between 3D and 2D parameters in knee OA.Methods: Sixty-six knees in 38 patients with varus knee OA underwent standing hip-to -ankle digital radiography and upright CT. The 2D parameters measured on radiographs included femorotibial angle (FTA), tibial joint line angle (TJLA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA). The 3D inner product angle between vectors of the tibial joint surface and the floor from CT was defined as the 3D joint surface-floor angle.Results: Mean 3D joint surface-floor angle was 6.0 +/- 3.6 degrees. No correlation was identified between 3D joint surface-floor angle and 2D joint line parameters, even though FTA corre-lated substantially with 2D joint line parameters. No significant differences in 3D joint surface-floor angle were identified among Coronal Plane Alignment of the Knee (CPAK) types.Conclusions: The 3D joint surface orientation did not correlate with 2D coronal joint line orientation and was unaffected by CPAK classification types. This finding suggests that cur-rent 2D evaluations should be reconsidered for a better understanding of true knee joint line orientation.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [31] THREE-DIMENSIONAL FINITE ELEMENT SIMULATION OF TOTAL KNEE JOINT IN GAIT CYCLE
    Guo, Yuan
    Zhang, Xushu
    Chen, Weiyi
    ACTA MECHANICA SOLIDA SINICA, 2009, 22 (04) : 347 - 351
  • [32] Three-dimensional measurement technique to assess implant position and orientation after total knee arthroplasty
    Jonkergouw, Filip
    Alle, Florence
    Chellaoui, Karim
    Sloten, Jos Vander
    Vangeneugden, Dieter
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) : 1513 - 1517
  • [33] A three-dimensional MRI analysis of knee kinematics
    Patel, VV
    Hall, K
    Ries, M
    Lotz, J
    Ozhinsky, E
    Lindsey, C
    Lu, Y
    Majumdar, S
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 283 - 292
  • [34] In vivo measurement of the three-dimensional motion of the sacroiliac joint
    Wilke, HJ
    Fischer, K
    Jeanneret, B
    Claes, L
    Magerl, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1997, 135 (06): : 550 - 556
  • [35] THREE-DIMENSIONAL FINITE ELEMENT SIMULATION OF TOTAL KNEE JOINT IN GAIT CYCLE
    Yuan Guo Xushu Zhang Weiyi Chen (The Institute of Applied Mechanics and Biomedical Engineering
    ActaMechanicaSolidaSinica, 2009, 22 (04) : 347 - 351
  • [36] Effects of childhood obesity on three-dimensional knee joint biomechanics during walking
    Gushue, DL
    Houck, J
    Lerner, AL
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2005, 25 (06) : 763 - 768
  • [37] Three-dimensional contact dynamic model of the human knee joint during walking
    Mun, JH
    Lee, DW
    KSME INTERNATIONAL JOURNAL, 2004, 18 (02): : 211 - 220
  • [38] A three-dimensional mathematical model of temporomandibular joint loading
    May, B
    Saha, S
    Saltzman, M
    CLINICAL BIOMECHANICS, 2001, 16 (06) : 489 - 495
  • [39] Gait deviations in individuals with inflammatory joint diseases and osteoarthritis and the usage of three-dimensional gait analysis
    Brostrom, Eva W.
    Esbjornsson, Anna-Clara
    von Heideken, Johan
    Iversen, Maura D.
    BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2012, 26 (03): : 409 - 422
  • [40] Three-dimensional volumetric measurement of the aortic root compared to standard two-dimensional measurements using cardiac computed tomography
    Suzuki, Masataka
    Mori, Shumpei
    Izawa, Yu
    Shimoyama, Shinsuke
    Takahashi, Yu
    Toh, Hiroyuki
    Tsuda, Daisuke
    Toba, Takayoshi
    Fujiwara, Sei
    Tanaka, Hidekazu
    Hirata, Ken-ichi
    Anderson, Robert H.
    Tretter, Justin T.
    CLINICAL ANATOMY, 2021, 34 (03) : 333 - 341