Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography

被引:7
|
作者
Sasaki, Ryo [1 ]
Niki, Yasuo [1 ,3 ]
Kaneda, Kazuya [1 ]
Yamada, Yoshitake [2 ]
Nagura, Takeo [1 ]
Nakamura, Masaya [1 ]
Jinzaki, Masahiro [2 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi Shinjuku, Tokyo 1608582, Japan
基金
日本学术振兴会;
关键词
Osteoarthritis; Upright CT; Tibial joint line; Three-dimensional evaluation; Varus alignment; KINEMATICALLY ALIGNED TKA; POSTERIOR TIBIAL SLOPE; ALIGNMENT; BIOMECHANICS; VARUS; ARTHROPLASTY; ASSOCIATION; GEOMETRY; AXIS;
D O I
10.1016/j.knee.2023.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Two-dimensional (2D) coronal joint line orientation on radiography under weight-bearing conditions has been widely used in evaluating knee osteoarthritis (OA). However, the effects of tibial rotation remain unknown. The present study aimed to newly define three-dimensional (3D) joint surface orientation relative to the floor as an unchangeable 3D angle unaffected by tibial rotation using upright computed tomography (CT), and to investigate correlations between 3D and 2D parameters in knee OA.Methods: Sixty-six knees in 38 patients with varus knee OA underwent standing hip-to -ankle digital radiography and upright CT. The 2D parameters measured on radiographs included femorotibial angle (FTA), tibial joint line angle (TJLA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA). The 3D inner product angle between vectors of the tibial joint surface and the floor from CT was defined as the 3D joint surface-floor angle.Results: Mean 3D joint surface-floor angle was 6.0 +/- 3.6 degrees. No correlation was identified between 3D joint surface-floor angle and 2D joint line parameters, even though FTA corre-lated substantially with 2D joint line parameters. No significant differences in 3D joint surface-floor angle were identified among Coronal Plane Alignment of the Knee (CPAK) types.Conclusions: The 3D joint surface orientation did not correlate with 2D coronal joint line orientation and was unaffected by CPAK classification types. This finding suggests that cur-rent 2D evaluations should be reconsidered for a better understanding of true knee joint line orientation.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [21] Three-dimensional joint kinematic and two-dimensional quality of movement comparison between lateral and forward step-downs
    Werner, David M.
    Davis, Ryne W.
    Hinton, Andrew
    Price, Samantha K.
    Rowland, Jimmy L.
    Barrios, Joaquin A.
    PHYSICAL THERAPY IN SPORT, 2021, 52 : 162 - 167
  • [22] A three-dimensional analysis of osteoarthritic changes in the thumb carpometacarpal joint
    de Raedt, S.
    Stilling, M.
    van de Giessen, M.
    Streekstra, G. J.
    Vos, F. M.
    Hansen, T. B.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (08) : 851 - 859
  • [23] Three-dimensional ultrasound for knee osteophyte depiction: a comparative study to computed tomography
    Valeria Vendries
    Tamas Ungi
    Jordan Harry
    Manuela Kunz
    Jana Podlipská
    Les MacKenzie
    Gabriel Venne
    International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 1749 - 1759
  • [24] Discrepancies in long-leg alignment and knee joint line obliquity between two- and three-dimensional measurements under weight-bearing conditions: Effects on coronal plane alignment of the knee classification
    Sasaki, Ryo
    Niki, Yasuo
    Kaneda, Kazuya
    Yamada, Yoshitake
    Kobayashi, Shu
    Harato, Kengo
    Nagura, Takeo
    Nakamura, Masaya
    Jinzaki, Masahiro
    KNEE, 2025, 53 : 237 - 245
  • [25] Three-dimensional ultrasound for knee osteophyte depiction: a comparative study to computed tomography
    Vendries, Valeria
    Ungi, Tamas
    Harry, Jordan
    Kunz, Manuela
    Podlipska, Jana
    MacKenzie, Les
    Venne, Gabriel
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (10) : 1749 - 1759
  • [26] Biomechanics of the Cricoarytenoid Joint: Three-Dimensional Imaging and Vector Analysis
    Storck, Claudio
    Juergens, Philipp
    Fischer, Claude
    Wolfensberger, Markus
    Honegger, Flurin
    Sorantin, Erich
    Friedrich, Gerhard
    Gugatschka, Markus
    JOURNAL OF VOICE, 2011, 25 (04) : 406 - 410
  • [27] Knee joint kinetics in response to multiple three-dimensional printed, customised foot orthoses for the treatment of medial compartment knee osteoarthritis
    Allan, Richard
    Woodburn, James
    Telfer, Scott
    Abbott, Mandy
    Steultjens, Martijn P. M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (06) : 487 - 498
  • [28] Three-dimensional knee joint contact forces during walking in unilateral transtibial amputees
    Silverman, Anne K.
    Neptune, Richard R.
    JOURNAL OF BIOMECHANICS, 2014, 47 (11) : 2556 - 2562
  • [29] An innovative method for the three-dimensional study of hip joint motion
    Bonneau, N.
    Bouhallier, J.
    Haeusler, M.
    Gagey, O.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 : 56 - 57
  • [30] Three-Dimensional Biometrics to Correlate Hindfoot and Knee Coronal Alignments Using Modern Weightbearing Imaging
    Dagneaux, Louis
    Dufrenot, Maryama
    Bernasconi, Alessio
    Bedard, Nicholas A.
    de Cesar Netto, Cesar
    Lintz, Francois
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (11) : 1411 - 1418