Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography

被引:7
|
作者
Sasaki, Ryo [1 ]
Niki, Yasuo [1 ,3 ]
Kaneda, Kazuya [1 ]
Yamada, Yoshitake [2 ]
Nagura, Takeo [1 ]
Nakamura, Masaya [1 ]
Jinzaki, Masahiro [2 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi Shinjuku, Tokyo 1608582, Japan
基金
日本学术振兴会;
关键词
Osteoarthritis; Upright CT; Tibial joint line; Three-dimensional evaluation; Varus alignment; KINEMATICALLY ALIGNED TKA; POSTERIOR TIBIAL SLOPE; ALIGNMENT; BIOMECHANICS; VARUS; ARTHROPLASTY; ASSOCIATION; GEOMETRY; AXIS;
D O I
10.1016/j.knee.2023.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Two-dimensional (2D) coronal joint line orientation on radiography under weight-bearing conditions has been widely used in evaluating knee osteoarthritis (OA). However, the effects of tibial rotation remain unknown. The present study aimed to newly define three-dimensional (3D) joint surface orientation relative to the floor as an unchangeable 3D angle unaffected by tibial rotation using upright computed tomography (CT), and to investigate correlations between 3D and 2D parameters in knee OA.Methods: Sixty-six knees in 38 patients with varus knee OA underwent standing hip-to -ankle digital radiography and upright CT. The 2D parameters measured on radiographs included femorotibial angle (FTA), tibial joint line angle (TJLA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA). The 3D inner product angle between vectors of the tibial joint surface and the floor from CT was defined as the 3D joint surface-floor angle.Results: Mean 3D joint surface-floor angle was 6.0 +/- 3.6 degrees. No correlation was identified between 3D joint surface-floor angle and 2D joint line parameters, even though FTA corre-lated substantially with 2D joint line parameters. No significant differences in 3D joint surface-floor angle were identified among Coronal Plane Alignment of the Knee (CPAK) types.Conclusions: The 3D joint surface orientation did not correlate with 2D coronal joint line orientation and was unaffected by CPAK classification types. This finding suggests that cur-rent 2D evaluations should be reconsidered for a better understanding of true knee joint line orientation.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [1] Extra-articular location of the three-dimensional mechanical axis in advanced knee osteoarthritis: an upright computed tomography study
    Sasaki, Ryo
    Kaneda, Kazuya
    Yamada, Yoshitake
    Niki, Yasuo
    Nakamura, Masaya
    Nagura, Takeo
    Jinzaki, Masahiro
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (12) : 1405 - 1413
  • [2] Three-Dimensional Computed Tomography Analysis of the Posterior Tibial Slope in 100 Knees
    Ho, Jade Pei Yuik
    Merican, Azhar M.
    Hashim, Muhammad Sufian
    Abbas, Azlina A.
    Chan, Chee Ken
    Mohamad, Jamal A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10) : 3176 - 3183
  • [3] Three-dimensional orientation of the acetabulum
    Suzuki, Daisuke
    Nagoya, Satoshi
    Takashima, Hiroyuki
    Tateda, Kenji
    Yamashita, Toshihiko
    CLINICAL ANATOMY, 2017, 30 (06) : 753 - 760
  • [4] Analysis of Three-dimensional Joint Space of the Tibiofemoral Joint
    Choi, Jang-Hwan
    McWalter, Emily J.
    Pal, Saikat
    Maier, Andreas
    Gold, Garry E.
    Fahrig, Rebecca
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Three-dimensional shoulder kinematics: Upright four-dimensional computed tomography in comparison with an optical three-dimensional motion capture system
    Yoshida, Yuki
    Matsumura, Noboru
    Miyamoto, Azusa
    Oki, Satoshi
    Yokoyama, Yoichi
    Yamada, Minoru
    Yamada, Yoshitake
    Nakamura, Masaya
    Nagura, Takeo
    Jinzaki, Masahiro
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 196 - 205
  • [6] Three-dimensional dynamic analysis of knee joint during gait in medial knee osteoarthritis using loading axis of knee
    Nishino, Katsutoshi
    Omori, Go
    Koga, Yoshio
    Kobayashi, Koichi
    Sakamoto, Makoto
    Tanabe, Yuji
    Tanaka, Masaei
    Arakawa, Masaaki
    GAIT & POSTURE, 2015, 42 (02) : 127 - 132
  • [7] THREE-DIMENSIONAL NUMERICAL SIMULATION OF HUMAN KNEE JOINT MECHANICS
    Trilha Junior, Marcial
    Fancello, Eduardo Alberto
    de Mello Roesler, Carlos Rodrigo
    Ocampo More, Ari Digiacomo
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (02): : 18 - 23
  • [8] Functional integrative analysis of the human hip joint: The three-dimensional orientation of the acetabulum and its relation with the orientation of the femoral neck
    Bonneau, Noemie
    Baylac, Michel
    Gagey, Olivier
    Tardieu, Christine
    JOURNAL OF HUMAN EVOLUTION, 2014, 69 : 55 - 69
  • [9] Three-dimensional anatomy of the ostrich (Struthio camelus) knee joint
    Chadwick, Kyle P.
    Regnault, Sophie
    Allen, Vivian
    Hutchinson, John R.
    PEERJ, 2014, 2
  • [10] Role of the proximal tibiofibular joint on the biomechanics of the knee joint: A three-dimensional finite element analysis
    Shao, Bin
    Xing, Jianqiang
    Zhao, Bei
    Wang, Tingguang
    Mu, Weidong
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (07): : 2446 - 2453