Block shear and tear-out in bolted connections as limited by curling

被引:2
作者
Pham, Viet Binh [1 ]
Pham, Cao Hung [1 ]
Hancock, Gregory J. [1 ]
机构
[1] Univ Sydney, Sch Civil Engn, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会;
关键词
Bolted connections; Cold-formed steel structures; Block shear and tear-out strengths; Curling effect; DESIGN;
D O I
10.1016/j.tws.2023.110754
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the literature, the block shear and tear-out phenomena and strengths of cold-formed steel bolted connections have been well understood and thoroughly investigated. However, the strength of these failure modes in the bolted connections between thin and thick plates may be governed by the effect of out of plane curling of the thin plate, and this phenomenon has not been studied in detail yet. It is apparent that the curling not only affects the shear strength but also changes the behaviour of the bolted connections. In particular, the design shear strength of the bolted connections remains unchanged with high ductility even though the end distance between the bolt holes and the free edge is becoming larger. An experimental program on the block shear and tear-out behaviour of bolted connections was performed at the University of Sydney in order to provide a better understanding on the effect of the curling. A total of 48 tests including thicknesses of thin plates (1.0 mm, 1.2 mm and 1.9 mm) and 10 mm thick plates was conducted at the University of Sydney with three configurations of bolted connections in conjunction with two different hole diameters (9 mm and 14 mm) and various end distances as the main variables. Three different failure modes being block shear, tear-out and curling were observed in the tests. In addition, different material properties of the cold-formed sheet steels (i.e., G300, G450, G500 and G550) were also considered in this program to create a large database for the investigation. Consequently, a design equation for block shear and tear-out strength accounting for the curling effect is proposed in this paper. It provides a better correlation with the experimental results than those predicted in the current Australian and New Zealand Standard (AS/NZS 4600) and the North American Specification for cold-formed steel structures (AISI S100). In addition, a calibrated Finite Element Model (FEM) was subsequently developed using the commercial finite element program ABAQUS to verify against the test results. The reliable data set of the FEM models is further utilised to extend the data range in a parametric study and is finally used for the verification procedure of the proposed formula over a wider range of data.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Experimental and shear bearing capacity studies of the assembled composite wall with bolted connections
    Huang, Wei
    Miao, Xinwei
    Hu, Gaoxing
    Fan, Zhenhui
    Zhang, Jiarui
    Ling, Ke
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (06)
  • [32] Shear lag and eccentricity effects of bolted connections in cold-formed steel sections
    Teh, Lip H.
    Yazici, Veysel
    ENGINEERING STRUCTURES, 2013, 52 : 536 - 544
  • [33] Seismic behavior of concrete shear walls with bolted end-plate DfD connections
    Ding, Tao
    Xiao, Jianzhuang
    Wei, Kaihua
    Lu, Yujie
    ENGINEERING STRUCTURES, 2020, 214
  • [34] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    SUN Jian
    QIU HongXing
    YANG Yuan
    LU Bo
    Science China(Technological Sciences), 2015, (08) : 1439 - 1448
  • [35] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    Jian Sun
    HongXing Qiu
    Yuan Yang
    Bo Lu
    Science China Technological Sciences, 2015, 58 : 1439 - 1448
  • [36] Ultimate strength of single shear two-bolted connections with austenitic stainless steel
    Kim, TaeSoo
    Lim, JinSeong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (01) : 117 - 128
  • [37] Clamped member fatigue characteristics of bolted connections subject to out-of-plane loading
    Zambino, Lee W.
    Ural, Ani
    ENGINEERING REPORTS, 2021, 3 (10)
  • [38] Improving the shear strength of bolted connections in pultruded GFRP using glass fiber sheets
    Nhut Phan Viet
    Yoresta, Fengky Satria
    Kitane, Yasuo
    Hashimoto, Kunitaro
    Matsumoto, Yukihiro
    COMPOSITE STRUCTURES, 2021, 255
  • [39] Analysis on Mechanical Properties of the Steel Plate Shear Wall with Fully Bolted and Welded Connections
    Mu Z.-G.
    Da H.
    Yang Y.-Q.
    Wang Z.
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2021, 42 (03): : 428 - 435
  • [40] An experimental study of the seismic behaviour of precast concrete shear walls with bolted-plate connections
    Pan, Guang-Bin
    Cai, Jian
    He, An
    Chen, Qing-Jun
    Zuo, Zhi-Liang
    He, Bing-Quan
    Tang, Xu-Lin
    Wu, Hong-Wei
    ENGINEERING STRUCTURES, 2021, 248