A Controlled Variable Study of the Biomechanical Properties of the Proximal Femur before and after Cancellous Bone Removal

被引:2
|
作者
Wang, Haicheng [1 ]
Ding, Kai [2 ]
Zhang, Yifan [2 ]
Ren, Chuan [2 ]
Huo, Haoyu [2 ]
Zhu, Yanbin [2 ]
Zhang, Qi [2 ]
Chen, Wei [2 ,3 ,4 ]
机构
[1] CangZhou Hosp Integrated TCM WM Hebei, Cangzhou City, Peoples R China
[2] Hebei Med Univ, Hosp 3, Dept Orthoped Surg, 139 Ziqiang Rd, Shijiazhuang 050051, Peoples R China
[3] Hebei Med Univ, Hosp 3, NHC Key Lab Intelligent Orthoped Equipment, Shijiazhuang, Peoples R China
[4] Key Lab Biomech Hebei Prov, Shijiazhuang, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Biomechanics; Bone density; Cancellous bone; Proximal femur; FEMORAL-NECK; STRENGTH; DISTRIBUTIONS; RESOLUTION; FRACTURES; AGE;
D O I
10.1111/os.14044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The biomechanical characteristics of proximal femoral trabeculae are closely related to the occurrence and treatment of proximal femoral fractures. Therefore, it is of great significance to study its biomechanical effects of cancellous bone in the proximal femur. This study examines the biomechanical effects of the cancellous bone in the proximal femur using a controlled variable method, which provide a foundation for further research into the mechanical properties of the proximal femur. Methods: Seventeen proximal femoral specimens were selected to scan by quantitative computed tomography (QCT), and the gray values of nine regions were measure to evaluated bone mineral density (BMD) using Mimics software. Then, an intact femur was fixed simulating unilateral standing position. Vertical compression experiments were then performed again after removing cancellous bone in the femoral head, femoral neck, and intertrochanteric region, and data were recorded. According to the controlled variable method, the femoral head, femoral neck, and intertrochanteric trabeculae were sequentially removed based on the axial loading of the intact femur, and the displacement and strain changes of the femur samples under axial loading were recorded. Gom software was used to measure and record displacement and strain maps of the femoral surface. Results: There was a statistically significant difference in anteroposterior displacement of cancellous bone destruction in the proximal femur (p < 0.001). Proximal femoral bone mass explained 77.5% of the strength variation, in addition proximal femoral strength was mainly affected by bone mass at the level of the upper outer, lower inner, lower greater trochanter, and lesser trochanter of the femoral head. The normal stress conduction of the proximal femur was destroyed after removing cancellous bone, the stress was concentrated in the femoral head and lateral femoral neck, and the femoral head showed a tendency to subside after destroying cancellous bone. Conclusion: The trabecular removal significantly altered the strain distribution and biomechanical strength of the proximal femur, demonstrating an important role in supporting and transforming bending moment under the vertical load. In addition, the strength of the proximal femur mainly depends on the bone density of the femoral head and intertrochanteric region.
引用
收藏
页码:1215 / 1229
页数:15
相关论文
共 50 条
  • [1] Biomechanical properties and clinical significance of cancellous bone in proximal femur: A review
    Wang, Haicheng
    Zhang, Yifan
    Ren, Chuan
    Ding, Kai
    Zhang, Qi
    Zhu, Yanbin
    Chen, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (06): : 1432 - 1438
  • [2] The Analysis of Biomechanical Properties of Proximal Femur after Implant Removal
    Yang, Jae Hyuk
    Jung, Tae Gon
    Honnurappa, Arjun Rupanagudi
    Cha, Jae Min
    Ham, Chang Hwa
    Kim, Tae Yoon
    Suh, Seung Woo
    APPLIED BIONICS AND BIOMECHANICS, 2016, 2016
  • [3] An experimental study on the biomechanical properties of the cancellous bones of distal femur
    Du, CJ
    Ma, HS
    Ruo, M
    Zhang, ZJ
    Yu, XJ
    Zeng, YJ
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (03) : 215 - 222
  • [4] Effects of spaceflight on cancellous and cortical bone in proximal femur in growing rats
    Gamboa, Amanda
    Branscum, Adam J.
    Olson, Dawn A.
    Sattgast, Lara H.
    Iwaniec, Urszula T.
    Turner, Russell T.
    BONE REPORTS, 2021, 14
  • [5] Structural and remodeling indices in the cancellous bone of the proximal femur across adulthood
    Tsangari, Helen
    Findlay, David M.
    Fazzalari, Nicola L.
    BONE, 2007, 40 (01) : 211 - 217
  • [6] Age-related cancellous bone loss in the proximal femur of Caucasian females
    Lundeen, GA
    Vajda, EG
    Bloebaum, RD
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 (06) : 505 - 511
  • [7] The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour
    Nicayenzi, B.
    Shah, S.
    Schemitsch, E. H.
    Bougherara, H.
    Zdero, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H11) : 1050 - 1060
  • [8] Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur
    Wachter, NJ
    Augat, P
    Mentzel, M
    Sarkar, MR
    Krischak, GD
    Kinzl, L
    Claes, LE
    BONE, 2001, 28 (01) : 133 - 139
  • [9] Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur
    Wachter, NJ
    Augat, P
    Hoellen, IP
    Krischak, GD
    Sarkar, MR
    Mentzel, M
    Kinzl, L
    Claes, L
    CLINICAL BIOMECHANICS, 2001, 16 (03) : 257 - 262
  • [10] Biomechanical Study of Proximal Femur for Designing Stems for Total Hip Replacement
    Solorzano, William
    Ojeda, Carlos
    Diaz Lantada, Andres
    APPLIED SCIENCES-BASEL, 2020, 10 (12):