Impact of Gore Cardioform Atrial Septal Defect Occluder on Atrial and Ventricular Electromechanics in a Pediatric Population

被引:0
作者
Castaldi, Biagio [1 ]
Santoro, Giuseppe [2 ]
Di Candia, Angela [1 ]
Marchese, Pietro [2 ]
Cantinotti, Massimiliano [2 ]
Pizzuto, Alessandra [2 ]
Scalera, Silvia [2 ]
Garibaldi, Silvia [2 ]
Fumanelli, Jennifer [2 ]
Sirico, Domenico [2 ]
Di Salvo, Giovanni [2 ]
机构
[1] Univ Padua, Dept Womens & Childrens Hlth, Pediat Cardiol Unit, Padua, Italy
[2] Fdn Toscana Gabriele Monasterio, Pediat Cardiol Unit, Massa, Italy
关键词
atrial septal defect; device; echocardiography; gore Cardioform device; interventional cardiology; speckle tracking; CONGENITAL HEART-DISEASE; PERCUTANEOUS CLOSURE; ASD OCCLUDER; TRANSCATHETER CLOSURE; SURGICAL CLOSURE; DEVICE CLOSURE; TASK-FORCE; CHILDREN; ADULTS; COMPLICATIONS;
D O I
10.1016/j.amjcard.2023.11.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure is the first-line treatment for ostium secundum atrial septal defect (ASD). The GORE Cardioform ASD Occluder (GCA) is potentially innovative compared with other self-centering devices. This study aimed to compare the mechanic changes in atrial and ventricular properties before and after GCA implantation. All consecutive patients aged <18 years who underwent isolated ASD closure with a single GCA device were enrolled from 2 centers. Echocardiography and electrocardiogram were performed the day before, 24 hours, and 6 months after ASD closure. Between January 2020 and February 2021, 70 pediatric patients with ASD were enrolled. The mean age was 7.9 +/- 3.9 years, and the mean defect diameter was 17.1 +/- 4.5 mm. Global longitudinal strain analysis showed no change in left ventricular longitudinal function (T0 -23.2 +/- 2.8%, 24 hours -23.0 +/- 2.8%, and 6 months -23.5 +/- 2.7%). An early and transient reduction in longitudinal strain was detected in the basal septal segments (T0 -19.8 +/- 3.3%, 24 hours -18.7 +/- 3.6%, and 6 months -19.2 +/- 3.4%), left atrium (T0 41.4 +/- 15.3%, 29.2 +/- 1.4%, and 39.0 +/- 12.9%), and right ventricle (-27.6 +/- 5.4%, -23.6 +/- 5.0%, and -27.3 +/- 4.6) 24 hours after closure, secondary to hemodynamic changes because of flow redirection after ASD closure. Six months after the procedure, only the left atrium showed a mild global longitudinal strain reduction because of the presence of the device within the septum. GCA device had no impact on global and regional ventricular function. Atrial mechanics were preserved, except for the segments covered by the device. This is the first device demonstrating no impact on the left and right ventricular mechanics, irrespective of the device size.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 33 条
[1]   Analysis of atrial and ventricular performance by tissue Doppler imaging in patients with atrial septal defects before and after surgical and catheter closure [J].
Abd El Rahman, MY ;
Hui, W ;
Timme, J ;
Ewert, P ;
Berger, F ;
Dsebissowa, F ;
Hetzer, R ;
Lange, PE ;
Abdul-Ehaliq, H .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (07) :579-585
[2]   Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk [J].
Amin, Z ;
Hijazi, ZM ;
Bass, JL ;
Cheatham, JP ;
Hellenbrand, WE ;
Kleinman, CS .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) :496-502
[3]   How to do right ventricular strain [J].
Badano, Luigi P. ;
Muraru, Denisa ;
Parati, Gianfranco ;
Haugaa, Kristina ;
Voigt, Jens-Uwe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (08) :825-827
[4]   Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging [J].
Badano, Luigi P. ;
Kolias, Theodore J. ;
Muraru, Denisa ;
Abraham, Theodore P. ;
Aurigemma, Gerard ;
Edvardsen, Thor ;
D'Hooge, Jan ;
Donal, Erwan ;
Fraser, Alan G. ;
Marwick, Thomas ;
Mertens, Luc ;
Popescu, Bogdan A. ;
Sengupta, Partho P. ;
Lancellotti, Patrizio ;
Thomas, James D. ;
Voigt, Jens-Uwe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) :591-600
[5]  
Baumgartner Helmut, 2021, Eur Heart J, V42, P563, DOI [10.1093/eurheartj/ehaa554, 10.15829/1560-4071-2021-4702]
[6]   Valvular and congenital heart disease -: Treatment of isolated secundum atrial septal defects:: Impact of age and defect morphology in 1,013 consecutive patients [J].
Butera, Gianfranco ;
Romagnoli, Enrico ;
Carminati, Mario ;
Chessa, Massimo ;
Piazza, Luciane ;
Negura, Diana ;
Giamberti, Alessandro ;
Abella, Raul ;
Pome, Giuseppe ;
Condoluci, Claudia ;
Frigiola, Alessandro .
AMERICAN HEART JOURNAL, 2008, 156 (04) :706-712
[7]   Percutaneous Closure of Patent Foramen Ovale and Secundum Atrial Septal Defects with the GORE® CARDIOFORM Septal Occluder: Incidence and Implications of Device Wire Frame Fracture [J].
Castaldi, Biagio ;
Cabrelle, Giulio ;
Padalino, Massimo ;
Vida, Vladimiro ;
Milanesi, Ornella ;
Di Salvo, Giovanni .
CONGENITAL HEART DISEASE, 2020, 15 (05) :347-360
[8]   Late Electrical and Mechanical Remodeling After Atrial Septal Defect Closure in Children: Surgical Versus Percutaneous Approach [J].
Castaldi, Biagio ;
Vida, Vladimiro L. ;
Argiolas, Anna ;
Maschietto, Nicola ;
Cerutti, Alessia ;
Gregori, Dario ;
Stellin, Giovanni ;
Milanesi, Ornella .
ANNALS OF THORACIC SURGERY, 2015, 100 (01) :181-187
[9]   Impact of the Amplatzer Atrial Septal Occluder Device on Left Ventricular Function in Pediatric Patients [J].
Castaldi, Biagio ;
Santoro, Giuseppe ;
Di Salvo, Giovanni ;
Gaio, Gianpiero ;
Palladino, Maria Teresa ;
D'Aiello, Fabio ;
Iacono, Carola ;
Pacileo, Giuseppe ;
Calabro, Raffaele ;
Russo, Maria Giovanna .
PEDIATRIC CARDIOLOGY, 2013, 34 (07) :1645-1651
[10]   Initial Clinical Experience With the GORE® CARDIOFORM ASD Occluder for Transcatheter Atrial Septal Defect Closure [J].
de Hemptinne, Quentin ;
Horlick, Eric M. ;
Osten, Mark D. ;
Millan, Xavier ;
Tadros, Victor-Xavier ;
Pighi, Michele ;
Barlatey, Francisco Gonzalez ;
Alnasser, Sami M. ;
Miro, Joaquim ;
Asgar, Anita W. ;
Ibrahim, Reda .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) :495-503