Handheld ultrasound-guided cannulation of difficult hemodialysis arteriovenous access: A randomized controlled trial

被引:3
作者
Chen, Shune [1 ]
Liu, Justin Shuang [2 ]
Chai, Chung Cheen [3 ]
Si, Chanjuan [1 ]
Tan, Si Hui [1 ]
Ravindran, Hanita Rajah [1 ]
Martinez, Ma Teresa Pedrosa [1 ]
Gao, Yang [1 ]
Yeap, Ying Ru [1 ]
Liu, Allen Yan Lun [3 ,4 ]
机构
[1] Khoo Teck Puat Hosp, Renal Ctr, Singapore, Singapore
[2] Minist Hlth Holdings Pte Ltd, Singapore, Singapore
[3] Khoo Teck Puat Hosp, Dept Med, Div Renal Med, Singapore, Singapore
[4] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
基金
英国医学研究理事会;
关键词
arteriovenous fistula; hemodialysis; ultrasonography; vascular access; FISTULA;
D O I
10.1111/hdi.13050
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction Cannulation of complex arteriovenous fistula (AVF) or graft (AVG) frequently poses challenges to renal nursing practice. Ultrasound (US) guidance on visualizing central and peripheral venous access has been widely adopted in nephrology, reducing vascular intervention complications. Renal nurses could acquire this point-of-care technique to increase the successful cannulation rate while facilitating confidence build-up during practice. We aim to evaluate the use of handheld US on difficult AVF/AVG cannulation in a hospital-based dialysis unit. Methods We conducted a single-center randomized controlled trial from January 2021 to January 2022. Ten renal nurses were trained by an interventional nephrologist before patient recruitment and had completed a pre- and posttraining questionnaire on their confidence level. Fifty hemodialysis patients with complex AVF were randomized to US-guided or conventional cannulation. The total time spent on cannulation and patients' pain scores were also collected. Findings Renal nurses increased their confidence level after training (pretraining score 26.6 +/- 6.9 vs. posttraining score 36.4 +/- 3.0; p = 0.014). There was a higher success rate (only one cannulation attempt required) for US-guided (96%) versus conventional (72.0%) cannulation (p = 0.049). US-guided cannulation had a lower pain score than the conventional method (1.48 +/- 0.73 vs. 2.13 +/- 0.95, p = 0.012). The pre-cannulation assessment time and time spent on cannulation were comparable between the two groups. Discussion Our study showed that US-guided cannulation increased renal nurses' confidence level in difficult cannulation and improved success rate. Larger scale studies are required to further assess the applications of handheld US in AVF cannulation, particularly in different clinical settings (e.g., chronic dialysis centers).
引用
收藏
页码:21 / 27
页数:7
相关论文
共 19 条
[1]   Timing of cannulation of arteriovenous grafts: are we too cautious? [J].
Al Shakarchi, Julien ;
Inston, Nicholas .
CLINICAL KIDNEY JOURNAL, 2015, 8 (03) :290-292
[2]   Effectiveness of ultrasound-guided cannulation of AVF on infiltration rates: A single center quality improvement study* [J].
Dua Niyyar, Vandana ;
Buch, Kunal ;
Rawls, Forest ;
Broxton, Rodella .
JOURNAL OF VASCULAR ACCESS, 2023, 24 (02) :322-328
[3]   A randomised clinical trial of ultrasound guided cannulation of difficult fistulae for dialysis access [J].
Eves, Joshua ;
Cai, Paris ;
Latham, Ross ;
Leung, Clement ;
Carradice, Daniel ;
Chetter, Ian ;
Smith, George .
JOURNAL OF VASCULAR ACCESS, 2021, 22 (04) :635-641
[4]   Improving vascular access outcomes: attributes of arteriovenous fistula cannulation success [J].
Harwood, Lori E. ;
Wilson, Barbara M. ;
Oudshoorn, Abe .
CLINICAL KIDNEY JOURNAL, 2016, 9 (02) :303-309
[5]   Coronal mode ultrasound guided hemodialysis cannulation: A pilot randomized comparison with standard cannulation technique [J].
Kumbar, Lalathaksha ;
Soi, Vivek ;
Adams, Elizabeth ;
Brown Deacon, Cheryl ;
Zidan, Mohamed ;
Yee, Jerry .
HEMODIALYSIS INTERNATIONAL, 2018, 22 (01) :23-30
[6]  
Luehr A, 2018, NEPHROL NURS J, V45, P423
[7]   Ultrasound-based simulation for cannulation in outpatient hemodialysis units: An educational protocol [J].
Niyyar, Vandana Dua .
JOURNAL OF VASCULAR ACCESS, 2021, 22 (04) :585-589
[8]   Cannulation technique influences arteriovenous fistula and graft survival [J].
Parisotto, Maria Teresa ;
Schoder, Volker U. ;
Miriunis, Cristina ;
Grassmann, Aileen H. ;
Scatizzi, Laura P. ;
Kaufmann, Peter ;
Stopper, Andrea ;
Marcelli, Daniele .
KIDNEY INTERNATIONAL, 2014, 86 (04) :790-797
[9]   Bedside Ultrasonography for Arteriovenous Fistula Cannulation [J].
Patel, Roshan A. ;
Stern, Aaron S. ;
Brown, Maritza ;
Bhatti, Saad .
SEMINARS IN DIALYSIS, 2015, 28 (04) :433-434
[10]   Endovascular techniques for cannulation difficulties in dialysis access [J].
Powell, Steven ;
Chan, Tze .
JOURNAL OF VASCULAR ACCESS, 2014, 15 :S96-S100