Development and experimental seismic study of bearing-two-level yielding energy dissipation beam-column-slab joints for precast concrete frames

被引:12
作者
Zhang, Jianxin [1 ,2 ]
Zhang, Tingwei [1 ]
Yuan, Weitao [1 ]
机构
[1] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Key Lab Prefabricated Bldg & Intelligent Construct, Tianjin 300401, Peoples R China
基金
中国国家自然科学基金;
关键词
Seismic performance; Precast concrete frame joint; Bearing-two-level yield behavior; Damage control; Bending moment capacity; PERFORMANCE; CONNECTIONS;
D O I
10.1016/j.jobe.2024.108779
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast concrete (PC) structures always collapsed under strong earthquakes causing unpredictable damage and difficult post-earthquake repair. To achieve fast assembly and seismic resilience, a new type of damage-controllable beam-column-slab joint with a bearing-two-level yielding energy dissipation (BTED) connector for fully PC frames was proposed. The BTED mechanism was achieved by the successive yielding of low- and high-strength steel in BTED connector to dissipate energy in stages under different earthquake levels. Meanwhile, the limited-slip components were arranged above the BTED connector to control the cracking damage of the PC slab. To comprehensively understand the seismic performance and the replaceability of the proposed joint, cyclic loading tests were carried out on five specimens, including three PC joints, one post-repaired PC specimen, and one monolithic joint. The failure modes, load-displacement curves, strength and stiffness, and energy dissipation capacity were investigated. Test results showed that the monolithic joint exhibited flexural failure with serious concrete crushing and reinforcement fracture, while the PC joint achieved the PC beam, column, and slab remaining elastic and concentrated the damage at the BTED connector, whose two-level-stage yield mechanism was effectively realized. The PC joint with BTED connector exhibited improved post-yield stiffness, enhanced seismic performance, and excellent post-earthquake repairability. The repaired joint behaved highly similar damage development and seismic performance to the previous joint. Moreover, the design methods of the first- and second-stage yield bending moments of the joint with BTED connector were proposed and verified to be in good agreement with the experimental results.
引用
收藏
页数:18
相关论文
共 40 条
[21]   Development of double-stage yielding coupling beam damper [J].
Pan, Peng ;
Cao, Yingri ;
Wang, Haishen ;
Sun, Jiangbo .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
[22]   Experimental study of a post-tensioned precast concrete beam-column joint with energy dissipaters and partially-precast slabs [J].
Qing, Yuan ;
Liu, Ye ;
Wang, Chun-Lin ;
Du, Dongsheng ;
Meng, Shaoping .
ENGINEERING STRUCTURES, 2023, 285
[23]   Experimental investigation of a multistage buckling-restrained brace [J].
Ben Sitler ;
Takeuchi, Toru ;
Matsui, Ryota ;
Terashima, Masao ;
Terazawa, Yuki .
ENGINEERING STRUCTURES, 2020, 213
[24]   Experimental study on seismic performance of prefabricated replaceable beam-column connectors using double-sided angle steel [J].
Sun, Dongde ;
Yang, Yong ;
Ma, Yinke ;
Xue, Yicong ;
Yu, Yunlong ;
Feng, Shiqiang .
JOURNAL OF BUILDING ENGINEERING, 2022, 51
[25]   Experimental Study on Two Simple Mechanical Precast Beam-Column Connections under Reverse Cyclic Loading [J].
Vidjeapriya, R. ;
Jaya, K. P. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2013, 27 (04) :402-414
[26]   Test of precast pre-stressed beam-to-column joint with damage-free reinforced concrete slab [J].
Wang, Haishen ;
Barbagallo, Francesca ;
Pan, Peng .
ENGINEERING STRUCTURES, 2020, 210
[27]   Cyclic behavior of metallic damper connected reinforced concrete beam-column joint with an opening in slab [J].
Wu, Congxiao ;
Zhang, Qian ;
Huang, Weiyuan ;
Zhang, Shaohua ;
Xu, Xin .
JOURNAL OF BUILDING ENGINEERING, 2022, 60
[28]   Experimental study of mechanical properties of beam-column joint of a replaceable energy-dissipation connector-precast concrete frame [J].
Xie, Luqi ;
Wu, Jing ;
Zhang, Jinyang ;
Liu, Chenyu .
JOURNAL OF BUILDING ENGINEERING, 2021, 43
[29]   Development and experimental verification of damage controllable energy dissipation beam to column connection [J].
Xu, Long-He ;
Zhang, Ge ;
Xiao, Shui-Jing ;
Li, Zhong-Xian .
ENGINEERING STRUCTURES, 2019, 199
[30]   Seismic experimental study on a precast concrete beam-column connection with grout sleeves [J].
Yan, Qiushi ;
Chen, Tianyi ;
Xie, Zhiyong .
ENGINEERING STRUCTURES, 2018, 155 :330-344