Biomechanical comparison of distal femoral fracture fixation: Polyaxial vs. uniaxial locking screws with different blocking screw configurations in retrograde femoral nailing

被引:0
作者
Batar, Suat [1 ]
Soylemez, Mehmet Salih [1 ]
Bozdag, Sureyya Ergun [2 ]
Yaman, Enis [2 ]
Kemah, Bahattin [1 ]
Poyanli, Oguz Sukru [3 ]
机构
[1] Umraniye Training & Res Hosp, Dept Orthopaed & Traumatol, Adem Yavuz Cd, TR-34764 Umraniye Istanbul, Turkiye
[2] Istanbul Tech Univ, Fac Mech Engn, Istanbul, Turkiye
[3] Medeniyet Univ, Suleyman Yalcin City Hosp, Fac Med, Dept Orthopaed & Traumatol, Istanbul, Turkiye
关键词
Distal femoral fracture; Retrograde intramedullary nail; Blocking screw; Polyaxial locking screw; Biomechanics; POLLER SCREWS; FEMUR FRACTURES; INTRAMEDULLARY NAIL; TIBIAL FRACTURES; SHAFT FRACTURES; PLACEMENT; PLATE;
D O I
10.1016/j.otsr.2023.103695
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures. Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw. Materials and methods: Third-generation custom -made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n = 10/group). Group A employed distal fixation with three 4.5 -mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N/mm/deg), axial load to failure (N), torsional load to failure (N/mm), coronal and sagittal angulations, and fracture site collapse. Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (p = 0.039 and p = 0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (p = 0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (p = 0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (p = 0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (p = 0.01). Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures. Level of evidence: N/A. (c) 2023 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:7
相关论文
共 27 条
  • [1] Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect"
    Auston, Darryl
    Donohue, David
    Stoops, Kyle
    Cox, Jacob
    Diaz, Miguel
    Santoni, Brandon
    Mir, Hassan
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (11) : 559 - 564
  • [2] Biewener A, 2002, UNFALLCHIRURG, V105, P65, DOI 10.1007/s113-002-8167-4
  • [3] TORSIONAL DEFORMITY AFTER INTRAMEDULLARY NAILING OF FEMORAL-SHAFT FRACTURES - MEASUREMENT OF ANTEVERSION ANGLES IN 110 PATIENTS
    BRATEN, M
    TERJESEN, T
    ROSSVOLL, I
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05): : 799 - 803
  • [4] DONALD G, 1983, CLIN ORTHOP RELAT R, P64
  • [5] Mono- versus polyaxial locking plates in distal femur fractures - a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
    El-Zayat, Bilal Farouk
    Efe, Turgay
    Ruchholtz, Steffen
    Khatib, Salim
    Timmesfeld, Nina
    Krueger, Antonio
    Zettl, Ralph
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [6] The use of 'blocking' screws for the 'closed' reduction of difficult proximal and distal femoral fractures
    Garnavos, Christos
    [J]. EFORT OPEN REVIEWS, 2021, 6 (06) : 451 - 458
  • [7] Blocking screws: an adjunct to retrograde nailing for distal femoral shaft fractures
    Gavaskar, Ashok S.
    Chowdary, Naveen
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (02) : 158 - 162
  • [8] Gellman RE, 1996, CLIN ORTHOP RELAT R, P90
  • [9] Distal femoral fixation: A biomechanical comparison of retrograde nail, retrograde intramedullary nail, and prototype locking retrograde nail
    Heiney, Jake P.
    Battula, Suneel
    O'Connor, Jill A.
    Ebraheim, Nabil
    Schoenfeld, Andrew J.
    Vrabec, Gregory
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (07) : 692 - 696
  • [10] Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate
    Heiney, Jake P.
    Barnett, Michael D.
    Vrabec, Gregory A.
    Schoenfeld, Andrew J.
    Baji, Avinash
    Njus, Glen O.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02): : 443 - 449