A study on the model of solar radiation transfer in multi-layer glass facade with attached droplets

被引:3
作者
Wang, Yanjin [1 ]
Xiong, Jintao [1 ]
Chen, Lingyu [2 ]
Lv, Zhihai [1 ]
Wang, Qian [1 ]
机构
[1] East China Jiaotong Univ, Coll Civil Engn & Architecture, Nanchang 330013, Jiangxi, Peoples R China
[2] East China JiaoTong Univ, Planning & Finance Dept, Nanchang 330013, Jiangxi, Peoples R China
关键词
Multi -layer glass facade system; Attached droplets; Solar radiation transfer model; Monte Carlo ray tracing method; Experiment validation; DOUBLE-SKIN FACADE; TRANSMITTANCE; PERFORMANCE; WINDOWS; WATER; TRANSMISSION; CONDENSATION; REFLECTANCE; IMPACT; FILM;
D O I
10.1016/j.ijthermalsci.2023.108763
中图分类号
O414.1 [热力学];
学科分类号
摘要
To obtain the optical properties of the spray cooling double skin facade (SC-DSF), a solar radiation transfer model of the multi-layer glass system with attached droplets is proposed in this study. The solar radiation is segmented into direct and diffuse radiation, and the monte carlo ray tracing method and angle discretization method are used to obtain the optical properties of the single layer glass with attached droplets. And then, the energy balance equation of the multilayer glass system is established based on the net-radiation method, and the transmittance, reflectance and absorptance of the multilayer glass system are calculated. The effectiveness of the proposed method is verified by the experimental results, which shows the numerical results are in good agreement with the experimental data. In addition, some important influence factors are analyzed and discussed, including the solar incidence angle, the droplet contact angle, the droplet coverage rate, and the average droplet diameter. It is found that there is little influence on the system transmittance when the incidence angle is smaller than 40 degrees. However, the transmittance decreases with the increase of the incidence angle when the solar incidence angle is greater than 40 degrees. When the droplet contact angle is small (less than 40 degrees) or large (larger than 140 degrees), its influence on the transmittance of the system is negligible. Subsequently, with the increase in the droplet contact angle within 40-140 degrees, the transmittance firstly decreases and then increases. Adjusting the droplet coverage rate and droplet size is an effective measure to decrease transmittance and solar heat gain.
引用
收藏
页数:13
相关论文
共 46 条
[1]   Numerical modeling of ventilated wall cavities with spray evaporative cooling system [J].
Alaidroos, Alaa ;
Krarti, Moncef .
ENERGY AND BUILDINGS, 2016, 130 :350-365
[2]   Evaluation of the cooling effect provided by a green facade as nature-based system for buildings [J].
Convertino, Fabiana ;
Vox, Giuliano ;
Schettini, Evelia .
BUILDING AND ENVIRONMENT, 2021, 203
[3]   Numerical and experimental validation of the solar radiation transfer for an egg-crate shading device under Mediterranean climate conditions [J].
Dominguez-Torres, Carlos-Antonio ;
Luis Leon-Rodriguez, Angel ;
Suarez, Rafael ;
Dominguez-Delgado, Antonio .
SOLAR ENERGY, 2019, 183 :755-767
[4]  
[董佰扬 Dong Baiyang], 2020, [动力工程学报, Journal of Chinese Society of Power Engineering], V40, P1002
[5]   Exploring the advantages and challenges of double-skin facades (DSFs) [J].
Ghaffarianhoseini, Ali ;
Ghaffarianhoseini, Amirhosein ;
Berardi, Umberto ;
Tookey, John ;
Li, Danny Hin Wa ;
Kariminia, Shahab .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 :1052-1065
[6]  
Haeringer S.F., 2020, J. Facade Des. Eng., V8, P131, DOI [10.7480/jfde.2020.1.4796, DOI 10.7480/JFDE.2020.1.4796]
[7]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[8]   Transmittance of transparent horizontal and tilted windows supporting large non-absorbing pendant droplets [J].
Hoeniges, Jack ;
Zhu, Keyong ;
Welch, William ;
Simsek, Eylul ;
Pilon, Laurent .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2021, 275
[9]   Performance study of a new type of transmissive concentrating system for solar photovoltaic glass curtain wall [J].
Hong, Ming ;
Feng, Chaoqing ;
Xu, Zhao ;
Zhang, Lizhuang ;
Zheng, Hongfei ;
Wu, Gang .
ENERGY CONVERSION AND MANAGEMENT, 2019, 201
[10]   Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems [J].
Huang, Junchao ;
Chen, Xi ;
Yang, Hongxing ;
Zhang, Weilong .
APPLIED ENERGY, 2018, 229 :1048-1060