Delivery of Aerosolized Bronchodilators by High-Flow Nasal Cannula During COPD Exacerbation

被引:10
|
作者
Colaianni-Alfonso, Nicolas [1 ,5 ]
MacLoughlin, Ronan [2 ,3 ,4 ]
Espada, Ariel [1 ]
Saa, Yasmine [1 ]
Techera, Mariano [1 ]
Toledo, Ada [1 ]
Montiel, Guillermo [1 ]
Castro-Sayat, Mauro [1 ]
机构
[1] Hosp Gen Agudos Juan A Fernandez, Resp Intermediate Care Unit, Buenos Aires, Argentina
[2] Aerogen Ltd, Res & Dev, Sci & Emerging Technol, Galway, Ireland
[3] Royal Coll Surgeons Ireland, Sch Pharm & Biomol Sci, Dublin, Ireland
[4] Trinity Coll Dublin, Sch Pharm & Pharmaceut Sci, Dublin, Ireland
[5] Hosp Juan A Fernandez, Resp Intermediate Care Unit, Av Cervino 3356, RA-C1425 Buenos Aires, Argentina
关键词
COPD; high-flow nasal cannula oxygen; nebulization; aerosol; respiratory function tests; THERAPY; OXYGEN;
D O I
10.4187/respcare.10614
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Bronchodilator delivery via a high-flow nasal cannula (HFNC) has generated interest in recent years. The efficacy of in-line vibrating mesh nebulizers with an HFNC during COPD exacerbation is limited. The aim of this study was to evaluate the clinical response of subjects with COPD exacerbation who require bronchodilator therapy (anticholinergic and b-agonist) by using a vibrating mesh nebulizer in line with an HFNC. METHODS: This was a prospective single-center study performed in a respiratory intermediate care unit that enrolled patients with a diagnosis of COPD exacerbation who required noninvasive ventilation on admission. All the subjects underwent noninvasive ventilation breaks with an HFNC. After clinical stability, pulmonary function tests were performed to assess changes in FEV1 and clinical parameters before and after bronchodilation by using a vibrating mesh nebulizer in line with an HFNC. RESULTS: Forty-six patients with COPD exacerbation were admitted. Five patients who did not use noninvasive ventilation and 10 patients who did not receive bronchodilator treatment with a vibrating mesh nebulizer were excluded. Thirty-one were selected, but 1 subject was secondarily excluded due to loss of data. Finally, 30 subjects were included. The primary outcome was spirometric changes in FEV1. The mean +/- SD FEV1 before receiving bronchodilator treatment by using a vibrating mesh nebulizer in line with an HFNC was 0.74 6 0.10 L, and, after receiving treatment, the mean +/- SD FEV1 changed to 0.88 +/- 0.12 L (P <.001). Similarly, the mean 6 SD FVC increased from 1.75 +/- 0.54 L to 2.13 +/- 0.63 L (P <.001). Considerable differences were observed in breathing frequency and heart rate after receiving bronchodilator treatment. No relevant changes were observed in the Borg scale or SpO(2) after treatment. The mean clinical stability recorded was 4 d. CONCLUSIONS: In subjects with COPD exacerbation, bronchodilator treatment by using a vibrating mesh nebulizer in line with an HFNC showed a mild but significant improvement in FEV1 and FVC. In addition, a decrease in breathing frequency was observed, suggesting a reduction in dynamic hyperinflation.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [41] A pediatric high-flow nasal cannula protocol standardizes initial flow and expedites weaning
    Wiser, Robert K.
    Smith, Ashlee C.
    Khallouq, Bertha B.
    Chen, Jerome G.
    PEDIATRIC PULMONOLOGY, 2021, 56 (05) : 1189 - 1197
  • [42] Reducing Overutilization of High-flow Nasal Cannula in Children with Bronchiolitis
    Jo, Diana
    Gupta, Nisha
    Bastawrous, David
    Busch, Hayley
    Neptune, Asha
    Weis, Amy
    Port, Courtney
    PEDIATRIC QUALITY & SAFETY, 2023, 8 (05)
  • [43] The Use of High-Flow Nasal Cannula Oxygen Outside the ICU
    Zemach, Sasson
    Helviz, Yigal
    Shitrit, Michal
    Friedman, Reuven
    Levin, Phillip D.
    RESPIRATORY CARE, 2019, 64 (11) : 1333 - 1342
  • [44] Humidification Performance of Two High-Flow Nasal Cannula Devices: A Bench Study
    Chikata, Yusuke
    Izawa, Masayo
    Okuda, Nao
    Itagaki, Taiga
    Nakataki, Emiko
    Onodera, Mutsuo
    Imanaka, Hideaki
    Nishimura, Masaji
    RESPIRATORY CARE, 2014, 59 (08) : 1186 - 1190
  • [45] The Current State of High-Flow Nasal Cannula Protocols at Children's Hospitals
    Willer, Robert J.
    Brady, Patrick W.
    Tyler, Amy N.
    Treasure, Jennifer D.
    Coon, Eric R.
    HOSPITAL PEDIATRICS, 2023, 13 (05) : e109 - e113
  • [46] Clinical Effectiveness of High-Flow Nasal Cannula in Hypoxaemic Patients during Bronchoscopic Procedures
    Chung, Sang Mi
    Choi, Ju Whan
    Lee, Young Seok
    Choi, Jong Hyun
    Oh, Jee Youn
    Min, Kyung Hoon
    Hur, Gyu Young
    Lee, Sung Yong
    Shim, Jae Jeong
    Kang, Kyung Ho
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2019, 82 (01) : 81 - 85
  • [47] Inspiratory Tube Condensation During High-Flow Nasal Cannula Therapy: A Bench Study
    Chikata, Yusuke
    Unai, Kazuaki
    Izawa, Masayo
    Okuda, Nao
    Oto, Jun
    Nishimura, Masaji
    RESPIRATORY CARE, 2016, 61 (03) : 300 - 305
  • [48] High-flow nasal cannula for respiratory failure in adult patients
    Park, SeungYong
    ACUTE AND CRITICAL CARE, 2021, 36 (04) : 275 - 285
  • [49] High-Flow Nasal Cannula for Neonatal Respiratory Distress: Is It Enough?
    Hornik, Christoph P.
    Turner, David A.
    RESPIRATORY CARE, 2011, 56 (12) : 1972 - 1974
  • [50] High-Flow Nasal Cannula in the Pediatric ICU: Popular or Efficient?
    Baudin, Florent
    Pouyau, Robin
    RESPIRATORY CARE, 2017, 62 (08) : 1116 - 1117