Three-dimensional turbo spin-echo (TSE) MRI assessment of indirect acute muscle injuries in athletes: comparison with two-dimensional TSE MRI

被引:0
|
作者
Minssen, Lise [1 ,2 ]
Renoux, Jerome [1 ,3 ]
Abar, Guillaume [1 ]
Moya, Loris [1 ,3 ]
Brasseur, Jean-Louis [1 ,4 ]
Li, Ling [5 ]
Crema, Michel D. [1 ,6 ,7 ]
机构
[1] French Natl Inst Sports INSEP, Inst Sports Imaging, 11 Ave Tremblay, F-75012 Paris, France
[2] UPMC Sorbonne Univ, St Antoine Hosp, APHP, Dept Radiol, Paris, France
[3] Amer Hosp Paris, Dept Radiol, Paris, France
[4] Imagerie Med Plaine France IMPF, Dept Radiol, Montfermeil, France
[5] Pfizer Inc, Dept Stat, New York, NY USA
[6] French Natl Inst Sports INSEP, Dept Sports Med, Paris, France
[7] Boston Univ, Sch Med, Dept Radiol, Quantitat Imaging Ctr, Boston, MA 02215 USA
关键词
Magnetic resonance imaging; Skeletal muscle; Classification; PROFESSIONAL FOOTBALL; RETURN; PLAY;
D O I
10.1007/s00330-022-09005-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To evaluate three-dimensional (3D) turbo spin-echo (TSE) magnetic resonance imaging (MRI) for the assessment of acute muscle injuries in elite athletes in comparison with two-dimensional (2D) MRI. Methods Elite athletes with clinically suspected acute muscle injury of the thigh who underwent both 2D and 3D MRI protocols on the same day were retrospectively included. Two musculoskeletal radiologists independently assessed 2D and 3D MRIs, with both techniques evaluated separately 1-month apart. Muscle injuries were evaluated using the BAMIC and the INSEP classifications. A second assessment of injuries was performed by each reader 2 months after the initial readings. Agreement was determined using weighted kappa statistics. The level of diagnostic confidence in classifying injuries was also assessed for both MRI protocols. Results A total of 40 athletes were included. Intra-reader agreement when comparing injury grades from 2D vs. 3D for both INSEP and BAMIC classifications was almost perfect for both readers and ranged between 0.84 and 0.98. Inter-reader agreement was substantial to almost perfect and ranged from 0.78 to 0.93 for the 2D protocol, and from 0.78 to 0.95 for the 3D protocol. Intra-reader agreement for each MRI protocol separately was almost perfect to perfect for both readers and ranged between 0.84 and 1.00. Diagnostic confidence for grading injuries improved for both readers when using the 3D protocol. Conclusions Compared to 2D MRI, 3D TSE MRI is a reliable technique for acute muscular injury assessment, providing faster acquisition times and improving the diagnostic confidence.
引用
收藏
页码:587 / 594
页数:8
相关论文
共 48 条
  • [1] Three-dimensional turbo spin-echo (TSE) MRI assessment of indirect acute muscle injuries in athletes: comparison with two-dimensional TSE MRI
    Lise Minssen
    Jérôme Renoux
    Guillaume Abar
    Loris Moya
    Jean-Louis Brasseur
    Ling Li
    Michel D. Crema
    European Radiology, 2023, 33 : 587 - 594
  • [2] Three-dimensional turbo spin-echo magnetic resonance imaging (MRI) and semiquantitative assessment of knee osteoarthritis: comparison with two-dimensional routine MRI
    Crema, M. D.
    Nogueira-Barbosa, M. H.
    Roemer, F. W.
    Marra, M. D.
    Niu, J.
    Chagas-Neto, F. A.
    Gregio-Junior, E.
    Guermazi, A.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (03) : 428 - 433
  • [3] Comparison of two-dimensional gradient echo, turbo spin echo and two-dimensional turbo gradient spin echo sequences in MRI of the cervical spinal cord anatomy
    Held, P
    Seitz, J
    Fründ, R
    Nitz, W
    Lenhart, M
    Geissler, A
    EUROPEAN JOURNAL OF RADIOLOGY, 2001, 38 (01) : 64 - 71
  • [4] Internal derangements of the temporomandibular joint: comparison of assessment with three-dimensional gradient-echo and spin-echo MRI
    Yamada, I
    Murata, Y
    Shibuya, H
    Suzuki, S
    NEURORADIOLOGY, 1997, 39 (09) : 661 - 667
  • [5] Internal derangements of the temporomandibular joint: comparison of assessment with three-dimensional gradient-echo and spin-echo MRI
    I. Yamada
    Y. Murata
    H. Shibuya
    S. Suzuki
    Neuroradiology, 1997, 39 : 661 - 667
  • [6] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [7] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [8] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Jing Zhang
    Lang Chen
    Qiu-Xia Wang
    Rong Liu
    Wen-Zhen Zhu
    Xin Luo
    Li Peng
    Wei Xiong
    Neuroradiology, 2015, 57 : 357 - 365
  • [9] Comparison between T2-weighted two-dimensional and three-dimensional fast spin-echo MRI sequences for characterizing thoracolumbar intervertebral disc disease in small-breed dogs
    Lee, Suhyeon
    Hwang, Jeongyeon
    Ko, Jaeeun
    Jeong, Jeongyun
    Eom, Kidong
    Kim, Jaehwan
    VETERINARY RADIOLOGY & ULTRASOUND, 2022, 63 (02) : 216 - 223
  • [10] Preoperative assessment of idiopathic scoliosis in adolescent and young adult with three-dimensional T2-weighted spin-echo MRI
    Duchaussoy, T.
    Lacoste, M.
    Norberciak, L.
    Decaudain, J.
    Verclytte, S.
    Budzik, J. -F.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (06) : 371 - 379