Coordinated restoration of inverter-based power sources and synchronous generators for the high renewable penetrated power system considering the dynamic frequency regulation capability

被引:2
|
作者
Yang, Chao [1 ,2 ]
Liao, Huanxin [1 ,3 ]
Liang, Gaoqi [4 ]
Gao, Huisheng [5 ]
Xin, Huanhai [5 ]
Zhao, Junhua [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Sch Sci & Engn, Shenzhen, Peoples R China
[2] Univ Sci & Technol China, Sch Math Sci, Hefei, Peoples R China
[3] Shenzhen Inst Artificial Intelligence & Robot Soc, Shenzhen, Peoples R China
[4] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen, Peoples R China
[5] Zhejiang Univ, Coll Elect Engn, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
coordinated restoration; dynamic frequency regulation capability; high renewable penetrated power system; interaction; inverter-based power sources; power grid resilience; LCC-HVDC; RECONFIGURATION; MODEL;
D O I
10.1049/rpg2.12889
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Extensive inverter-based power sources (IPS) impose significant challenges on the restoration of high renewable penetrated power systems (HRPPS). To enhance HRPPS resilience, the proper utilization of IPSs must be implemented. Combining frequency dynamics of IPSs and synchronous generators, this paper proposes a coordinated restoration method for multi-type power sources after a major blackout. First, interactions between synchronous generators and IPSs are systematically analyzed. Based on this, output characteristics and constraints of IPSs in the power sources restoration process are quantified. Second, the dynamic frequency regulation capability (DFRC) of restored systems is quantified based on a unified transfer function structure model. Then the maximum power disturbance that restored systems can bear is derived based on DFRC indices including the maximum frequency deviation and the rate of change of frequency. Third, considering interactions between power sources and the DFRC of restored systems, a coordinated restoration optimization model of multi-type power sources is proposed. Finally, case studies based on a modified IEEE 39-bus system are simulated to verify the applicability and superiority of the proposed method. Meanwhile, results show that the proposed method for quantifying DFRC is more suitable for HRPPSs than traditional inertia-based methods.
引用
收藏
页码:1292 / 1303
页数:12
相关论文
共 10 条
  • [1] Dynamic power flow algorithm considering frequency regulation of wind power generators
    Wang, Ruohan
    Xie, Yuzheng
    Zhang, Hengxu
    Li, Changgang
    Li, Wei
    Terzija, Vladimir
    IET RENEWABLE POWER GENERATION, 2017, 11 (08) : 1218 - 1225
  • [2] Coordinated control of conventional power sources and PHEVs using jaya algorithm optimized PID controller for frequency control of a renewable penetrated power system
    Annamraju, Anil
    Nandiraju, Srikanth
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2019, 4 (01)
  • [3] An ADMM-based power system partitioned black-start and parallel restoration method considering high-penetrated renewable energy
    Wang, Zekai
    Ding, Tao
    Mu, Chenggang
    Huang, Yuhan
    Yang, Miao
    Yang, Yueyang
    Chen, Zhiming
    Lin, Yi
    Li, Meng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [4] Energy management of distribution network with inverter-based renewable virtual power plant considering voltage security index
    Azarhooshang, Alireza
    Rezazadeh, Alireza
    IET RENEWABLE POWER GENERATION, 2024, 18 (01) : 126 - 140
  • [5] Modelling spatiotemporal impact of flash floods on power distribution system and dynamic service restoration with renewable generators considering interdependent critical loads
    Afzal, Suhail
    Mokhlis, Hazlie
    Illias, Hazlee Azil
    Bajwa, Abdullah Akram
    Mekhilef, Saad
    Mubin, Marizan
    Muhammad, Munir Azam
    Shareef, Hussain
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (02) : 368 - 387
  • [6] Impact of Communication Time Delay in a 5G Network on Frequency Regulation Performance of a High Renewable Energy Penetrated Power System
    He, Hongjie
    Cai, Xiao
    Su, Yibo
    Zhang, Xianfeng
    Zhang, Ning
    Ci, Song
    Zhou, Yanglin
    Kang, Chongqing
    IEEE INTERNET OF THINGS JOURNAL, 2024, 11 (14): : 24376 - 24388
  • [7] A Modified DSC-Based Grid Synchronization Method for a High Renewable Penetrated Power System Under Distorted Voltage Conditions
    Li, Tie
    Li, Yunlu
    Yang, Junyou
    Ge, Weichun
    Hu, Bo
    ENERGIES, 2019, 12 (21)
  • [8] A DSE-Based Power System Frequency Restoration Strategy for PV-Integrated Power Systems Considering Solar Irradiance Variations
    Yu, Shenglong
    Zhang, Lijun
    Iu, Herbert Ho-Ching
    Fernando, Tyrone
    Wong, Kit Po
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2017, 13 (05) : 2511 - 2518
  • [9] Dynamic Performance Improving Strategy for Primary Frequency Regulation With Energy Storages in High Penetration of RESs Power System
    He, Li
    Guo, Luoquan
    Tan, Zhuangxi
    Chen, Chaoyang
    Li, Xinran
    Huang, Jiyuan
    Li, Xueyuan
    IEEE ACCESS, 2024, 12 : 139560 - 139572
  • [10] A Novel Hybridized Fuzzy PI-LADRC Based Improved Frequency Regulation for Restructured Power System Integrating Renewable Energy and Electric Vehicles
    Sharma, Prateek
    Mishra, Abhishek
    Saxena, Abhishek
    Shankar, Ravi
    IEEE ACCESS, 2021, 9 : 7597 - 7617