Technical Factors Contributing to Nonunion in Supracondylar Distal Femur Fractures Treated With Lateral Locked Plating: A Risk-Stratified Analysis

被引:3
|
作者
Stockton, David J. [1 ]
O'Hara, Nathan N. [1 ]
Brodke, Dane J. [2 ]
Mckibben, Natasha [1 ]
Healey, Kathleen [1 ]
Goch, Abraham [1 ]
Demyanovich, Haley [1 ]
Devana, Sai [2 ]
Hernandez, Adolfo [2 ]
Burke, Cynthia E. [1 ]
Gupta, Jayesh [1 ]
Marchand, Lucas S. [3 ]
Dekeyser, Graham J. [3 ]
Steffenson, Lillia [3 ]
Shymon, Stephen J. [4 ]
Fairres, Marshall J. [4 ]
Perdue, Paul W. [5 ]
Barber, Colby [5 ]
Atassi, Omar H. [6 ]
Mitchell, Thomas W. [6 ]
Working, Zachary M. [7 ]
Black, Loren O. [7 ]
El Naga, Ashraf N. [8 ]
Roddy, Erika [8 ]
Hogue, Matthew [9 ]
Gulbrandsen, Trevor [9 ]
Morellato, John [10 ]
Gillon, W. Hunter [10 ]
Walters, Murphy M. [10 ]
Hempen, Eric [1 ]
Slobogean, Gerard P. [1 ]
Lee, Christopher [2 ]
O'Toole, Robert V. [1 ]
机构
[1] Univ Maryland, R Adams Cowley Shock Trauma Ctr, Dept Orthopaed, Sch Med, 22 S Greene St, Baltimore, MD 21201 USA
[2] Univ Calif Los Angeles, Dept Orthopaed Surg, Los Angeles, CA USA
[3] Univ Utah Hosp, Dept Orthopaed, Salt Lake City, UT USA
[4] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA USA
[5] Virginia Commonwealth Univ, Dept Orthopaed Surg, Richmond, VA USA
[6] Baylor Coll Med, Dept Orthoped Surg, Houston, TX USA
[7] Oregon Hlth & Sci Univ, Dept Orthopaed & Rehabil, Portland, OR USA
[8] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA USA
[9] Univ Iowa, Dept Orthoped & Rehabil, Iowa City, IA USA
[10] Univ Mississippi, Dept Orthopaed Surg & Rehabil, Med Ctr, Jackson, MS USA
基金
美国国家卫生研究院;
关键词
lateral locked plating; nonunion; supracondylar distal femur fracture; risk factors; WORKING LENGTH; MODIFIED RUST; PLATES; FIXATION;
D O I
10.1097/BOT.0000000000002680
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
OBJECTIVE: To identify technical factors associated with nonunion after operative treatment with lateral locked plating.Design: Retrospective cohort study.Setting: Ten Level I trauma centers.Patient Selection Criteria:Adult patients with supracondylar distal femur fractures (OTA/AO type 33A or C) treated with lateral locked plating from 2010 through 2019.Outcome Measures and Comparisons:Surgery for nonunion stratified by risk for nonunion.RESULTS: The cohort included 615 patients with supracondylar distal femur fractures. The median patient age was 61 years old (interquartile range: 46 -72years) and 375 (61%) were female. Observed were nonunion rates of 2% in a low risk of nonunion group (n = 129), 4% in a medium-risk group (n = 333), and 14% in a high-risk group (n = 153). Varus malreduction with an anatomic lateral distal femoral angle greater than 84 degrees, was associated with double the odds of nonunion compared to those without such varus [odds ratio, 2.1; 95% confidence interval (CI), 1.1-4.2; P = 0.03]. Malreduction by medial translation of the articular block increased the odds of nonunion, with 30% increased odds per 4 mm of medial translation (95% CI, 1.0-1.6; P = 0.03). Working length increased the odds of nonunion in the medium risk group, with an 18% increase in nonunion per 10-mm increase in working length (95% CI, 1.0-1.4; P = 0.01). Increased proximal screw density was protective against nonunion (odds ratio, 0.71; 95% CI, 0.53-0.92; P = 0.02) but yielded lower mRUST scores with each 0.1 increase in screw density associated with a 0.4-point lower mRUST (95% CI, -0.55 to -0.15; P < 0.001). Lateral plate length and type of plate material were not associated with nonunion. (P > 0.05).CONCLUSIONS: Malreduction is a surgeon-controlled variable associated with nonunion after lateral locked plating of supracondylar distal femur fractures. Longer working lengths were associated with nonunion, suggesting that bridge plating may be less likely to succeed for longer fractures.LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 21 条
  • [1] Risk Factors for Nonunion of Distal Femur Fractures
    Cone, Ryan
    Roszman, Alex
    Conway, Yvonne
    Cichos, Kyle
    McGwin, Gerald
    Spitler, Clay A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (04) : 175 - 180
  • [2] Lateral locked plating for distal femur fractures by low-energy trauma: what makes a difference in healing?
    Kim, Sang-Min
    Yeom, Jae-Woo
    Song, Hyung Keun
    Hwang, Kyu-Tae
    Hwang, Ji-Hyo
    Yoo, Je-Hyun
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (12) : 2907 - 2914
  • [3] Low risk of nonunion with lateral locked plating of distal femoral fractures-A retrospective study of 191 consecutive patients
    Wenger, Daniel
    Andersson, Sanet
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (02): : 448 - 452
  • [4] Radiostereometric Analysis of Stability and Inducible Micromotion After Locked Lateral Plating of Distal Femur Fractures
    Galea, Vincent P.
    Botros, Mina A.
    McTague, Michael F.
    Weaver, Michael J.
    Vrahas, Mark S.
    Malchau, Henrik
    Heng, Marilyn
    Bragdon, Charles
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (02) : E60 - E66
  • [5] Mechanical Construct Characteristics Predisposing to Non-union After Locked Lateral Plating of Distal Femur Fractures
    Rodriguez, Edward K.
    Zurakowski, David
    Herder, Lindsay
    Hall, Amber
    Walley, Kempland C.
    Weaver, Mike J.
    Appleton, Paul T.
    Vrahas, Mark
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (08) : 403 - 408
  • [6] Is retrograde nailing superior to lateral locked plating for complete articular distal femur fractures?
    Vemulapalli, K. Chandra
    Pechero, Guillermo R.
    Warner, Stephen J.
    Achor, Timothy S.
    Gary, Joshua L.
    Munz, John W.
    Choo, Andrew M.
    Prasarn, Mark L.
    Routt, Milton L. Chip, Jr.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 640 - 644
  • [7] Predictive factors of distal femoral fracture nonunion after lateral locked plating: A retrospective multicenter case-control study of 283 fractures
    Rodriguez, Edward K.
    Boulton, Christina
    Weaver, Michael J.
    Herder, Lindsay M.
    Morgan, Jordan H.
    Chacko, Aron T.
    Appleton, Paul T.
    Zurakowski, David
    Vrahas, Mark S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 554 - 559
  • [8] Clinical and Radiographic Results of a Retrograde Nail-Washer Combination Versus Lateral Locked Plating for Distal Femur Fractures
    Shaath, M. Kareem
    Kerr, Matthew S.
    Haidukewych, George J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11) : 584 - 591
  • [9] Additional fixation of medial plate over the unstable lateral locked plating of distal femur fractures: A biomechanical study
    Park, Kyeong-Hyeon
    Oh, Chang-Wug
    Park, Il-Hyung
    Kim, Joon-Woo
    Lee, Jin-Han
    Kim, Hee-June
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1593 - 1598
  • [10] Lateral locked plating for distal femur fractures by low-energy trauma: what makes a difference in healing?
    Sang-Min Kim
    Jae-Woo Yeom
    Hyung Keun Song
    Kyu-Tae Hwang
    Ji-Hyo Hwang
    Je-Hyun Yoo