Factors that contribute to false-negative results in CT-guided transthoracic lung core-needle biopsy

被引:4
|
作者
Sun, Daqian [1 ]
Yao, Tianxiao [1 ]
Wang, Lixin [2 ]
Ma, Shengmei [1 ]
Gao, Min [2 ]
Li, Jingshuo [1 ]
Li, Chunhai [1 ]
Xu, Lisheng [3 ,4 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan, Peoples R China
[2] Shandong Univ, Sch Nursing & Rehabil, Jinan, Peoples R China
[3] Shandong Univ, Qilu Hosp, Dept Pulm & Crit Care Med, Jinan, Peoples R China
[4] Shandong Univ, Qilu Hosp, Jinan, Peoples R China
关键词
False-negative results; non-specific benign; risk factors; COMPUTED-TOMOGRAPHY; PULMONARY-LESIONS; CANCER; EXPERIENCE; ASPIRATION; NODULES; BENIGN; MODEL; TRUE;
D O I
10.4103/jcrt.jcrt_2054_22
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To investigate the possibility of false-negative occurrence of non-specific benign pathological results on CT-guided transthoracic lung core-needle biopsy and identify risk factors for false-negative results.Methods: The clinical, imaging, and surgical data of 403 lung biopsy patients were retrospectively analyzed. Patients were divided into true-negative and false-negative (FN) groups according to the final diagnosis. Univariate analysis was used to compare the variables in two groups for statistical differences, and multivariate analysis was used to clarify the risk factors associated with FN results.Results: Of the 403 lesions, 332 were finally confirmed as benign and 71 to be malignant, with a FN rate of 17.6%. Older patient age (P = 0.01), burr sign (P = 0.00), and pleural traction sign (P = 0.02) were independent risk factors for FN results. The area under the receiver operating characteristic (ROC) curve's area under curve (AUC) was 0.73.Conclusion: CT-guided transthoracic lung core-needle biopsy has a high diagnostic accuracy and low rate of FN results. Older patient age, the burr sign, and the pleural traction sign are independent risk factors for FN results that should be monitored prior to surgery to reduce the risk of FN results.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [21] Radiographic and Clinical Characterization of False Negative Results from CT-Guided Needle Biopsies of Lung Nodules
    Gelbman, Brian D.
    Cham, Mathew D.
    Kim, Won
    Libby, Daniel M.
    Smith, James P.
    Port, Jeffrey L.
    Altorki, Nasser K.
    Henschke, Claudia I.
    Yankelevitz, David F.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (05) : 815 - 820
  • [22] CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique
    Wu, Reng-Hong
    Tzeng, Wen-Sheng
    Lee, Wei-Jing
    Chang, Shih-Chin
    Chen, Chia-Huei
    Fung, Jui-Lung
    Wang, Yen-Jen
    Mak, Chee-Wai
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) : E712 - E716
  • [23] CT-guided Transthoracic Core-Needle Biopsies of Mediastinal and Lung Lesions in 235 Consecutive Patients: Factors Affecting the Risks of Complications and Occurrence of a Final Diagnosis of Malignancy
    Cesar, Daniel Nicoletti
    Torres, Ulysses S.
    D'Ippolito, Giuseppe
    Souza, Arthur Soares
    ARCHIVOS DE BRONCONEUMOLOGIA, 2019, 55 (06): : 297 - 305
  • [24] Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy
    Youk, Ji Hyun
    Kim, Eun-Kyung
    Kim, Min Jung
    Kwak, Jin Young
    Son, Eun Ju
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 782 - 789
  • [25] Initial Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Lesions Performed by a Pulmonologist
    Ahn, June Hong
    Jang, Jong Geol
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
  • [26] CT-Guided Percutaneous Core Needle Biopsy in Typing and Subtyping Lung Cancer: A Comparison to Surgery
    Zhang, Hanfei
    Tian, Sufang
    Wang, Shan
    Liu, Songmei
    Liao, Meiyan
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [27] Factors influencing the total procedure time of CT-guided percutaneous core-needle biopsies of lung nodules: a retrospective analysis
    Sargent, Tyler
    Kolderman, Nathan
    Nair, Girish B.
    Jankowski, Michelle
    Al-Katib, Sayf
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2022, 28 (04) : 337 - 343
  • [28] Accuracy of CT-Guided Core-Needle Biopsy in Diagnosis of Thoracic Lesions Suspicious for Primitive Malignancy of the Lung: A Five-Year Retrospective Analysis
    Baratella, Elisa
    Cernic, Stefano
    Minelli, Pierluca
    Furlan, Giovanni
    Crimi, Filippo
    Rocco, Simone
    Ruaro, Barbara
    Cova, Maria Assunta
    TOMOGRAPHY, 2022, 8 (06) : 2828 - 2838
  • [29] Non-malignant pathological results from CT-guided biopsy for pulmonary nodules: a predictive model for identifying false-negative results
    Wang, Xu-Zhou
    Wang, Jing-Ya
    Meng, Tao
    Shi, Yi-Bing
    Sun, Jin-Jun
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [30] CT-guided transthoracic biopsy: histopathologic results and complication rates
    Aktas, Aykut Recep
    Gozlek, Emel
    Yilmaz, Omer
    Kayan, Mustafa
    Unlu, Nisa
    Demirtas, Hakan
    Degirmenci, Bumin
    Kara, Mustafa
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (01): : 67 - 70