A New Digital Method to Quantify the Effects Produced by Carriere Motion Appliance

被引:3
作者
Rodriguez, Aldara Rosalia Nercellas [1 ]
Gallardo, Pedro Colino [2 ]
Zubizarreta-Macho, Alvaro [1 ,3 ]
Paniagua, Carlos Colino [2 ]
Lorenzo, Alfonso Alvarado [1 ]
Martinez, Alberto Albaladejo [1 ]
机构
[1] Univ Salamanca, Fac Med, Dept Surg, Salamanca 37008, Spain
[2] European Univ Miguel de Cervantes, Dept Orthodont, Valladolid 47012, Spain
[3] Alfonso X El Sabio Univ, Fac Hlth Sci, Dept Endodont, Madrid 28691, Spain
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 05期
关键词
Carriere Distalizer; distalization; derotation; orthodontics; digital; MAXILLARY MOLAR DISTALIZATION; CLASS-II MALOCCLUSION; DISTAL JET; ARCH;
D O I
10.3390/jpm13050859
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The aim of this study was to analyze a novel digital technique to quantify the distal tooth displacement and derotation angle produced by the Carriere Motion Appliance (CMA). Twenty-one patients with a class II molar and canine relationship underwent orthodontic treatment with CMA. All patients were exposed before (STL1) and after the CMA placement (STL2), submitted to a digital impression, and afterwards, data were uploaded to specific cephalometric software to allow automatic mesh network alignment of the STL digital files. Subsequently, the distal tooth displacement of the upper canines and first upper molars, as well as the derotation angle of the first upper molars were analyzed using the Pearson correlation coefficient (?). Repeatability and reproducibility were analyzed using Gage R & R statistical analysis. An increase in canine displacement was correlated with an increase in contralateral canine displacement (? = 0.759; p < 0.000). An increase in canine displacement was correlated with an increase in molar displacement (? = 0.715; p < 0.001). An increase in upper first molar displacement was correlated with an increase in the contralateral upper first molar displacement (? = 0.609; p < 0.003) and the canine displacement (? = 0.728; p < 0.001). The distal tooth displacement showed a repeatability of 0.62% and reproducibility of 7.49%, and the derotation angle showed a repeatability of 0.30% and reproducibility of 0.12%. The novel digital measurement technique is a reproducible, repeatable, and accurate method for quantifying the distal tooth displacement of the upper canine and first upper molar, as well as the derotation angle of the first upper molars after using CMA.
引用
收藏
页数:14
相关论文
共 33 条
  • [1] Maxillary Molar Distalization with Noncompliance Intramaxillary Appliances in Class II Malocclusion
    Antonarakis, Gregory Stylianos
    Kiliaridis, Stavros
    [J]. ANGLE ORTHODONTIST, 2008, 78 (06) : 1133 - 1140
  • [2] The Class II Carriere Motion appliance: A 3D CBCT evaluation of the effects on the dentition
    Areepong, Daniel
    Kim, Ki Beom
    Oliver, Donald R.
    Ueno, Hiroshi
    [J]. ANGLE ORTHODONTIST, 2020, 90 (04) : 491 - 499
  • [3] Bailey D R, 1991, J Gen Orthod, V2, P26
  • [4] Treatment effects of Carriere Motion Appliance on patients with class II malocclusion: A systematic review and meta-analysis
    Barakat, Daniah
    Bakdach, Wesam Mhd Mounir
    Youssef, Mohamed
    [J]. INTERNATIONAL ORTHODONTICS, 2021, 19 (03) : 353 - 364
  • [5] Bolla E, 2002, ANGLE ORTHOD, V72, P481
  • [6] Carriere Luis, 2004, J Clin Orthod, V38, P224
  • [7] Chaques-Asensi J, 2001, J Clin Orthod, V35, P254
  • [8] A comparison of two intraoral molar distalization appliances: Distal jet versus pendulum
    Chiu, PP
    McNamara, JA
    Franchi, L
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (03) : 353 - 365
  • [9] Dahlquist A, 1996, EUR J ORTHODONT, V18, P257
  • [10] Fontana Mattia, 2012, Prog Orthod, V13, P173, DOI 10.1016/j.pio.2011.10.002