The Artificial Pancreas and Type 1 Diabetes

被引:22
作者
Nwokolo, Munachiso [1 ]
Hovorka, Roman [1 ]
机构
[1] Addenbrookes Hosp, Wellcome Trust MRC Inst Metab Sci, Box 289,Hills Rd, Cambridge CB2 0QQ, Cambs, England
基金
欧盟地平线“2020”;
关键词
type; 1; diabetes; artificial pancreas; automated insulin delivery; hybrid closed-loop; LOOP INSULIN DELIVERY; HYBRID CLOSED-LOOP; OPEN-LABEL; RANDOMIZED-TRIAL; GLUCOSE CONTROL; PUMP THERAPY; ADULTS; CROSSOVER; MULTICENTER; CHILDREN;
D O I
10.1210/clinem/dgad068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diabetes technologies represent a paradigm shift in type 1 diabetes care. Continuous subcutaneous insulin infusion (CSII) pumps and continuous glucose monitors (CGM) improve glycated hemoglobin (HbA1c) levels, enhance time in optimal glycemic range, limit severe hypoglycemia, and reduce diabetes distress. The artificial pancreas or closed-loop system connects these devices via a control algorithm programmed to maintain target glucose, partially relieving the person living with diabetes of this constant responsibility. Automating insulin delivery reduces the input required from those wearing the device, leading to better physiological and psychosocial outcomes. Hybrid closed-loop therapy systems, requiring user-initiated prandial insulin doses, are the most advanced closed-loop systems commercially available. Fully closed-loop systems, requiring no user-initiated insulin boluses, and dual hormone systems have been shown to be safe and efficacious in the research setting. Clinical adoption of closed-loop therapy remains in early stages despite recent technological advances. People living with diabetes, health care professionals, and regulatory agencies continue to navigate the complex path to equitable access. We review the available devices, evidence, clinical implications, and barriers regarding these innovatory technologies.
引用
收藏
页码:1614 / 1623
页数:10
相关论文
共 64 条
  • [1] Continuous subcutaneous insulin infusion: Special needs for children
    Adolfsson, Peter
    Ziegler, Ralph
    Hanas, Ragnar
    [J]. PEDIATRIC DIABETES, 2017, 18 (04) : 255 - 261
  • [2] [Anonymous], National Diabetes Audit Executive Summary 2009-2010
  • [3] Closed-loop for type 1 diabetes - an introduction and appraisal for the generalist
    Bally, Lia
    Thabit, Hood
    Hovorka, Roman
    [J]. BMC MEDICINE, 2017, 15
  • [4] Psychosocial aspects of closed-and open-loop insulin delivery: closing the loop in adults with Type 1 diabetes in the home setting
    Barnard, K. D.
    Wysocki, T.
    Thabit, H.
    Evans, M. L.
    Amiel, S.
    Heller, S.
    Young, A.
    Hovorka, R.
    [J]. DIABETIC MEDICINE, 2015, 32 (05) : 601 - 608
  • [5] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [6] Prevention of Hypoglycemia With Predictive Low Glucose Insulin Suspension in Children With Type 1 Diabetes: A Randomized Controlled Trial
    Battelino, Tadej
    Nimri, Revital
    Dovc, Klemen
    Phillip, Moshe
    Bratina, Natasa
    [J]. DIABETES CARE, 2017, 40 (06) : 764 - 770
  • [7] Beck Roy W, 2019, J Diabetes Sci Technol, V13, P614, DOI 10.1177/1932296818822496
  • [8] Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial
    Beck, Roy W.
    Riddlesworth, Tonya D.
    Ruedy, Katrina J.
    Kollman, Craig
    Ahmann, Andrew J.
    Bergenstal, Richard M.
    Bhargava, Anuj
    Bode, Bruce W.
    Haller, Stacie
    Kruger, Davida F.
    McGill, Janet B.
    Polonsky, William
    Price, David
    Toschi, Elena
    [J]. LANCET DIABETES & ENDOCRINOLOGY, 2017, 5 (09) : 700 - 708
  • [9] Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis
    Bekiari, Eleni
    Kitsios, Konstantinos
    Thabit, Hood
    Tauschmann, Martin
    Athanasiadou, Eleni
    Karagiannis, Thomas
    Haidich, Anna-Bettina
    Hovorka, Roman
    Tsapas, Apostolos
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2018, 361
  • [10] Closed-loop insulin delivery in adults with type 1 diabetes in real-life conditions: a 12-week multicentre, open-label randomised controlled crossover trial
    Benhamou, Pierre-Yves
    Franc, Sylvia
    Reznik, Yves
    Thivolet, Charles
    Schaepelynck, Pauline
    Renard, Eric
    Guerci, Bruno
    Chaillous, Lucy
    Lukas-Croisier, Celine
    Jeandidier, Nathalie
    Hanaire, Helene
    Borot, Sophie
    Doron, Maeva
    Jallon, Pierre
    Xhaard, Ilham
    Melki, Vincent
    Meyer, Laurent
    Delemer, Brigitte
    Guillouche, Marie
    Schoumacker-Ley, Laurene
    Farret, Anne
    Raccah, Denis
    Lablanche, Sandrine
    Joubert, Michael
    Penfornis, Alfred
    Charpentier, Guillaume
    [J]. LANCET DIGITAL HEALTH, 2019, 1 (01): : E17 - E25