Humeral bone defects in revision shoulder arthroplasty

被引:0
作者
Gohlke, Frank [1 ]
Berner, Arne [1 ]
Abdelkawi, Ayman [1 ]
机构
[1] Rhon Klinikum, Klin Orthopadie, Unfallchirurg Schulter & Ellenbogenchirurg & Endo, Campus Bad Neustadt Saale,Salzburger Leite 1, D-97616 Bad Neustadt an der Saale, Germany
来源
ORTHOPADIE | 2023年
关键词
Bone resorption; osteolysis; Humerus reconstruction; Reconstructive surgery; Shoulder replacement; Reverse shoulder arthroplasty; PROXIMAL HUMERUS; PROSTHESIS; RECONSTRUCTION; COMPOSITE; COMPLICATIONS; ALLOGRAFTS; FRACTURES;
D O I
10.1007/s00132-022-04335-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Revision shoulder arthroplasty is mainly performed with reverse TSA and should consider proper adjustment of the length and the amount of bone loss in humeral reconstruction. Whilst epi-/metaphyseal bone loss can mostly be compensated easily by stemmed standard implants, advanced bone loss exceeding 2 degrees requires the support of longer revision stems. Extensive humeral bone loss: Cementless fixation in the intact diaphyseal humerus is recommended in bone loss exceeding 2 degrees, preferably with modular revision systems, because cemented reverse revision stems have higher loosening rates in the mid to long-term follow-up. In cases of advanced bone loss 3 degrees-4 degrees (more than 6-7 cm), structural humeral allografts should be considered to prevent instability and early loosening. Unfortunately, the access to fresh frozen allografts is very limited due to regulation of the German government in contrast to the situation in the US or Switzerland. Reverse tumor arthroplasty is an option with a higher complication rate and inferior function even when polyester mesh is used for ingrowth of soft tissues. Distinct diaphyseal defects: In bone loss 4 degrees-5 degrees the minimal anchorage length is mostly critical due to the curvature of the medullary canal. The fixation of a revision stem is only possible when at least 2-3 widths of the diaphyseal diameter are available. Custom-made implants with flanges or distal locking screws, or bipolar tumor arthroplasty may be required. Additionally, strut allografts can be useful to achieve stable fixation. Two-stage biological reconstruction in impaction-bone-graft or the Masquelet technique are rarely used as a salvage procedure.
引用
收藏
页码:98 / 108
页数:10
相关论文
共 35 条
  • [1] Proximal Humerus Tumors: Higher-than-Expected Risk of Revision With Constrained Reverse Shoulder Arthroplasty
    Ayvaz, Mehmet
    Cetik, Riza Mert
    Bakircioglu, Sancar
    Tokgozoglu, A. Mazhar
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (11) : 2585 - 2595
  • [2] Complications in reverse shoulder arthroplasty
    Barco, Raul
    Savvidou, Olga D.
    Sperling, John W.
    Sanchez-Sotelo, Joaquin
    Cofield, Robert H.
    [J]. EFORT OPEN REVIEWS, 2016, 1 (03): : 72 - 80
  • [3] Complications and revision of reverse total shoulder arthroplasty
    Boileau, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) : S33 - S43
  • [4] Reverse shoulder-allograft prosthesis composite, with or without tendon transfer, for the treatment of severe proximal humeral bone loss
    Boileau, Pascal
    Raynier, Jean-Luc
    Chelli, Mikael
    Gonzalez, Jean-Francois
    Galvin, Joseph W.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (11) : E401 - E415
  • [5] Reconstruction by allograft-prosthetic composite reverse shoulder arthroplasty after proximal humerus tumor resection: Clinical and radiographic assessment at a minimum 2 years' follow-up
    Callamand, Gabriel
    Barret, Hugo
    Saint-Genez, Florian
    Bonnevialle, Paul
    Mansat, Pierre
    Bonnevialle, Nicolas
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (04)
  • [6] Revision Arthroplasty with Use of a Reverse Shoulder Prosthesis-Allograft Composite
    Chacon, Ariel
    Virani, Nazeem
    Shannon, Robert
    Levy, Jonathan C.
    Pupello, Derek
    Frankle, Mark
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) : 119 - 127
  • [7] Clinical outcomes following reverse shoulder arthroplasty-allograft composite for revision of failed arthroplasty associated with proximal humeral bone deficiency: 2-to 15-year follow-up
    Cox, Jacob L.
    McLendon, Paul B.
    Christmas, Kaitlyn N.
    Simon, Peter
    Mighell, Mark A.
    Frankle, Mark A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (05) : 900 - 907
  • [8] Do Early Results of Proximal Humeral Allograft-Prosthetic Composite Reconstructions Persist at 5-year Followup?
    El Beaino, Marc
    Liu, Jiayong
    Lewis, Valerae O.
    Lin, Patrick P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (04) : 758 - 765
  • [9] Reverse total shoulder arthroplasty for oncologic reconstruction of the proximal humerus: a systematic review
    Ferlauto, Harrison R.
    Wickman, John R.
    Lazarides, Alexander L.
    Hendren, Stephanie
    Visgauss, Julia D.
    Brigman, Brian E.
    Anakwenze, Oke A.
    Klifto, Christopher S.
    Eward, William C.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (11) : E647 - E658
  • [10] Periprosthetic humeral fractures associated with reverse total shoulder arthroplasty: incidence and management
    Garcia-Fernandez, Carlos
    Lopiz-Morales, Yaiza
    Rodriguez, Alberto
    Lopez-Duran, Luis
    Martinez, Fernando Marco
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 1965 - 1969