Studying Erythromelalgia Using Doppler Flowmetry Perfusion Signals and Wavelet Analysis-An Exploratory Study

被引:1
|
作者
Rodrigues, Luis Monteiro [1 ]
Caetano, Joana [1 ,2 ,3 ]
Andrade, Sergio Faloni [1 ]
Rocha, Clemente [1 ]
Alves, Jose Delgado [2 ,3 ]
Ferreira, Hugo Alexandre [4 ]
机构
[1] Univ Lusofona Lisboa, CBIOS Res Ctr Biosci & Hlth Technol, P-1700097 Lisbon, Portugal
[2] Hosp Fernando Fonseca, Immunomediated Syst Dis, Med 4, P-2720276 Amadora, Portugal
[3] Nova Univ Lisboa, Nova Med Sch, P-1169056 Lisbon, Portugal
[4] Univ Lisbon, Inst Biophys & Biomed Engn, Fac Sci, P-1749019 Lisbon, Portugal
关键词
erythromelalgia; skin perfusion; laser doppler flowmetry; wavelet analysis; REDUCES SYMPTOMS; SKIN PERFUSION; DOUBLE-BLIND; VASCULOPATHY; MANAGEMENT;
D O I
10.3390/biomedicines11123327
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Erythromelalgia (EM) is a rare disease, which is still poorly characterized. In the present paper, we compared the hand perfusion of one female EM patient, under challenges, with a healthy control group. Using a laser Doppler flowmeter (LDF) with an integrated thermal probe, measurements were taken in both hands at rest (Phase I) and after two separate challenges-post-occlusive hyperemia (PORH) in one arm (A) and reduction of skin temperature (cooling) with ice in one hand (B) (Phase II). The final measurement periods corresponded to recovery (Phases III and IV). The control group involved ten healthy women (27.3 +/- 7.9 years old). A second set of measurements was taken in the EM patient one month after beginning a new therapeutic approach with betablockers (6.25 mg carvedilol twice daily). Z-scores of the patient's LDF and temperature fluctuations compared to the control group were assessed using the Wavelet transform (WT) analysis. Here, fluctuations with |Z| > 1.96 were considered significantly different from healthy values, whereas positive or negative Z values indicated higher or lower deviations from the control mean values. Cooling elicited more measurable changes in LDF and temperature fluctuations, especially in higher frequency components (cardiac, respiratory, and myogenic), whereas PORH notably evoked changes in lower frequency components (myogenic, autonomic, and endothelial). No significant Z-score deviations were observed in the second measurement, which might signify a stabilization of the patient's distal perfusion following the new therapeutic approach. This analysis involving one EM patient, while clearly exploratory, has shown significant deviations in WT-derived physiological components' values in comparison with the healthy group, confirming the interest in using cold temperature as a challenger. The apparent agreement achieved with the clinical evaluation opens the possibility of expanding this approach to other patients and pathologies in vascular medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Identification of Gingival Microcirculation Using Laser Doppler Flowmetry in Patients with Orthodontic Treatment-A Longitudinal Pilot Study
    Laredo-Naranjo, Martha Alicia
    Patino-Marin, Nuria
    Martinez-Castanon, Gabriel Alejandro
    Medina-Solis, Carlo Eduardo
    Velazquez-Hernandez, Carolina
    Nino-Martinez, Nereyda
    Orozco, Marco Felipe Salas
    MEDICINA-LITHUANIA, 2021, 57 (10):
  • [32] A morphological study of CMEs using wavelet analysis
    Gonzalez-Gomez, D. I.
    Blanco-Cano, X.
    Raga, A. C.
    ADVANCES IN SPACE RESEARCH, 2010, 46 (01) : 22 - 30
  • [33] Isolation of Fetal ECG Signals from Abdominal ECG Using Wavelet Analysis
    Alshebly, Y. S.
    Nafea, M.
    IRBM, 2020, 41 (05) : 252 - 260
  • [34] Study on Simulation Signals of Blasting Seismic Waves Based on Technology of Wavelet Analysis
    Wei, Haixia
    HIGH PERFORMANCE STRUCTURES AND MATERIALS ENGINEERING, PTS 1 AND 2, 2011, 217-218 : 1595 - 1600
  • [35] Femoral bone blood flow after reaming and intramedullary canal preparation - A canine study using laser Doppler flowmetry
    ElMaraghy, AW
    Humeniuk, B
    Anderson, GI
    Schemitsch, EH
    Richards, RR
    JOURNAL OF ARTHROPLASTY, 1999, 14 (02) : 220 - 226
  • [36] Classification of washing machines vibration signals using discrete wavelet analysis for feature extraction
    Goumas, SK
    Zervakis, ME
    Stavrakakis, GS
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (03) : 497 - 508
  • [37] EFFECT OF SUBMUCOSAL EPINEPHRINE INJECTION ON LOCAL GASTRIC BLOOD-FLOW - A STUDY USING LASER DOPPLER FLOWMETRY AND REFLECTANCE SPECTROPHOTOMETRY
    CHUNG, SCS
    LEUNG, JWC
    LEUNG, FW
    DIGESTIVE DISEASES AND SCIENCES, 1990, 35 (08) : 1008 - 1011
  • [38] Using the wavelet analysis of secondary current signals for investigating and controlling electron beam welding
    Trushnikov, D.N.
    Welding International, 2013, 27 (06) : 460 - 465
  • [39] Classification of Epileptic Electroencephalograms Signals Using Combining Wavelet Analysis and Support Vector Machine
    Wang, Yong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (01) : 62 - 65
  • [40] Flute based Analysis of Ball-Nose Milling Signals Using Continuous Wavelet Analysis Features
    Torabi, Amin J.
    Massol, Olivier
    Joo, Er Meng
    Li Xiang
    Siong, Lim Beng
    Peen, Gan Oon
    Huang Sheng
    Gopikrishnan, Sudhan Raj
    Zhai Lianyin
    San Linn
    11TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION (ICARCV 2010), 2010, : 1359 - 1364