Studying Erythromelalgia Using Doppler Flowmetry Perfusion Signals and Wavelet Analysis-An Exploratory Study

被引:1
|
作者
Rodrigues, Luis Monteiro [1 ]
Caetano, Joana [1 ,2 ,3 ]
Andrade, Sergio Faloni [1 ]
Rocha, Clemente [1 ]
Alves, Jose Delgado [2 ,3 ]
Ferreira, Hugo Alexandre [4 ]
机构
[1] Univ Lusofona Lisboa, CBIOS Res Ctr Biosci & Hlth Technol, P-1700097 Lisbon, Portugal
[2] Hosp Fernando Fonseca, Immunomediated Syst Dis, Med 4, P-2720276 Amadora, Portugal
[3] Nova Univ Lisboa, Nova Med Sch, P-1169056 Lisbon, Portugal
[4] Univ Lisbon, Inst Biophys & Biomed Engn, Fac Sci, P-1749019 Lisbon, Portugal
关键词
erythromelalgia; skin perfusion; laser doppler flowmetry; wavelet analysis; REDUCES SYMPTOMS; SKIN PERFUSION; DOUBLE-BLIND; VASCULOPATHY; MANAGEMENT;
D O I
10.3390/biomedicines11123327
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Erythromelalgia (EM) is a rare disease, which is still poorly characterized. In the present paper, we compared the hand perfusion of one female EM patient, under challenges, with a healthy control group. Using a laser Doppler flowmeter (LDF) with an integrated thermal probe, measurements were taken in both hands at rest (Phase I) and after two separate challenges-post-occlusive hyperemia (PORH) in one arm (A) and reduction of skin temperature (cooling) with ice in one hand (B) (Phase II). The final measurement periods corresponded to recovery (Phases III and IV). The control group involved ten healthy women (27.3 +/- 7.9 years old). A second set of measurements was taken in the EM patient one month after beginning a new therapeutic approach with betablockers (6.25 mg carvedilol twice daily). Z-scores of the patient's LDF and temperature fluctuations compared to the control group were assessed using the Wavelet transform (WT) analysis. Here, fluctuations with |Z| > 1.96 were considered significantly different from healthy values, whereas positive or negative Z values indicated higher or lower deviations from the control mean values. Cooling elicited more measurable changes in LDF and temperature fluctuations, especially in higher frequency components (cardiac, respiratory, and myogenic), whereas PORH notably evoked changes in lower frequency components (myogenic, autonomic, and endothelial). No significant Z-score deviations were observed in the second measurement, which might signify a stabilization of the patient's distal perfusion following the new therapeutic approach. This analysis involving one EM patient, while clearly exploratory, has shown significant deviations in WT-derived physiological components' values in comparison with the healthy group, confirming the interest in using cold temperature as a challenger. The apparent agreement achieved with the clinical evaluation opens the possibility of expanding this approach to other patients and pathologies in vascular medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Spectral analysis of laser Doppler flowmetry signals
    Campos, Rita
    Figueiras, Edite
    Ferreira, Luis F. Requicha
    Humeau-Heurtier, Anne
    2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
  • [2] A study of perfusion of the distal free-TRAM flap using laser Doppler flowmetry
    Booi, Darren I.
    Debats, Iris B. J. G.
    Boeckx, Willy D.
    van der Hulst, Rene R. W. J.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (03) : 282 - 288
  • [3] Using laser Doppler flowmetry with wavelet analysis to study skin blood flow regulations after cupping therapy
    Hou, Xiao
    He, Xiangfeng
    Zhang, Xueyan
    Liao, Fuyuan
    Hung, Yu-Ju
    Jan, Yih-Kuen
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (03) : 393 - 399
  • [4] STUDY OF DIGITAL BLOOD PRESSURE AND LASER DOPPLER FLOWMETRY SIGNALS THROUGH A MULTISCALE ANALYSIS
    Guerreschi, Emmanuelle
    Humeau-Heurtier, Anne
    Bricq, Stephanie
    Mahe, Guillaume
    Leftheriotis, Georges
    2012 PROCEEDINGS OF THE 20TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2012, : 1796 - 1800
  • [5] IMPAIRED BLADDER PERFUSION IN INTERSTITIAL CYSTITIS - A STUDY OF BLOOD-SUPPLY USING LASER DOPPLER FLOWMETRY
    IRWIN, P
    GALLOWAY, NTM
    JOURNAL OF UROLOGY, 1993, 149 (04) : 890 - 892
  • [6] Minimizing the duration of laser Doppler flowmetry recordings while maintaining wavelet analysis quality: A methodological study
    Reynes, C.
    Vinet, A.
    Maltinti, O.
    Knapp, Y.
    MICROVASCULAR RESEARCH, 2020, 131
  • [7] Wavelet analysis of laser Doppler microcirculatory signals: Current applications and limitations
    Kralj, Lana
    Lenasi, Helena
    FRONTIERS IN PHYSIOLOGY, 2023, 13
  • [8] A novel procedure for evaluating gingival perfusion status using laser-Doppler flowmetry
    Patiño-Marín, N
    Martínez, F
    Loyola-Rodríguez, JP
    Tenorio-Govea, E
    Brito-Orta, MD
    Rodríguez-Martínez, M
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (03) : 231 - 237
  • [9] Free flap perfusion prediction by laser doppler flowmetry based time series analysis
    Kodama H.
    Ishida K.
    Hirayama H.
    Kishi K.
    Miyawaki T.
    Kodama, Hiroki (h18ms-kodama@jikei.ac.jp), 1600, Japan Soc. of Med. Electronics and Biol. Engineering (Annual59) : 628 - 630
  • [10] Investigation of errors in estimates of the frequency of signals of laser Doppler anemometers using wavelet analysis
    Kudryashov, TV
    Grechikhin, VA
    MEASUREMENT TECHNIQUES, 2002, 45 (07) : 732 - 737