Comparing inter- and intraobserver reliability between two-dimensional and three-dimensional measurements in the tibial component position of unicompartmental knee arthroplasty

被引:1
作者
Seki, Kazushige [1 ,3 ]
Seki, Toshihiro [1 ]
Siigi, Eiichi [2 ]
Imagama, Takashi [1 ]
Yamabe, Takamasa [1 ]
Sakai, Takashi [1 ]
机构
[1] Yamaguchi Univ, Dept Orthoped Surg, Grad Sch Med, Ube, Yamaguchi, Japan
[2] Yamaguchi Prefectural Grand Med Ctr, Dept Orthoped Surg, Hofu, Yamaguchi, Japan
[3] 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
来源
ACTA ORTHOPAEDICA BELGICA | 2023年 / 89卷 / 02期
关键词
unicompartmental knee arthroplasty; tibia; computed tomography; intra-and interobserver reliabilities; minimal detectable change; CLINICAL-OUTCOMES; ALIGNMENT; RADIOGRAPHS; AGREEMENT;
D O I
10.52628/89.2.10553
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In unicompartmental knee arthroplasty (UKA), the tibial component has a small coronal plane width, the tibia and tibial component rotations are mismatched, and the large tibial component posterior tilt may make accurate measurements of component positions difficult in radiography. The study aimed to assess the intra-and interobserver reliabilities of radiographic (2D) and 3D computed tomography (3D-CT) measurements and to determine the minimum detectable change (95% confidence level, MDC95) in the tibial component position measurements in UKA. The study included 23 females and 7 males. Two surgeons measured the tibial component position. Intraclass and interclass correlation coefficients (ICC) were calculated to obtain reliability, and Bland-Altman analysis was performed to assess systematic errors. The MDC95 was calculated according to MDC95 = standard error of measurement x 1.96 x root 2. In the 2D and 3D -CT measurements, intraobserver reliability for coronal and sagittal positions of the tibial component were sufficiently reliable, where ICCs were >0.8. In the coronal plane, the ICCs for interobserver reliability were lower in 2D (ICC, 0.5-0.7) than in 3D-CT (ICC > 0.9). Bland-Altman plots showed systematic bias in sagittal alignment in the 2D assessment. In the 3D assessment of intra-and interobserver reliability, the MDC95 of the coronal, sagittal, and axial planes was <2 degrees. In the 2D intra-and interobserver reliability, the MDC95 of the coronal and sagittal planes was >2 degrees. The 2D measurement had a risk of misidentifying the tibial component position in UKA.
引用
收藏
页码:316 / 325
页数:10
相关论文
共 50 条
[41]   Deviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty A pilot study in 13 patients [J].
Martinez-Carranza, Nicolas ;
Weidenhielm, Lars ;
Crafoord, Joakim ;
Hedstrom, Margareta .
ACTA ORTHOPAEDICA, 2012, 83 (06) :625-628
[42]   Short-to Mid-Term Survivorship of a Patient- specific Unicompartmental Knee Arthroplasty Implant Cast from a Three-Dimensional Printed Mold [J].
Mestriner, Alexandre Barbieri ;
Antonelli, Brielle ;
Schwab, Pierre-Emmanuel ;
Chen, Antonia F. ;
Jones, Todd ;
Ackermann, Jakob ;
Merkely, Gergo Bela ;
Lange, Jeffrey K. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2023, 54 (02) :193-199
[43]   Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method [J].
You, Sung-Hye ;
Suh, Sang-il ;
Ryoo, In-Seon ;
Son, Gyu-Ri ;
Lee, Young-Hen ;
Seo, Hyung Suk ;
Lee, Nam Joon ;
Seol, Hae Young .
ULTRASONOGRAPHY, 2017, 36 (01) :17-24
[44]   Lack of agreement between computer navigation and post-operative 2-dimensional computed tomography (CT) measurements for component and limb alignment in total knee arthroplasty (TKA) [J].
Dahabreh, Ziad ;
Scholes, Corey J. ;
Giuffre, Bruno ;
Coolican, Myles R. J. ;
Parker, David A. .
KNEE, 2016, 23 (01) :137-143
[45]   Does Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An In Vivo Three-Dimensional Analysis [J].
Peng, Yun ;
Arauz, Paul ;
An, Shuai ;
Limmahakhun, Sakkadech ;
Klemt, Christian ;
Kwon, Young-Min .
JOURNAL OF KNEE SURGERY, 2020, 33 (08) :798-803
[46]   Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo [J].
Oz, U. ;
Orhan, K. ;
Abe, N. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (08) :492-500
[47]   Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial [J].
Sariali, Elhadi ;
Kajetanek, Charles ;
Catonne, Yves .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (11) :2529-2538
[48]   Two-dimensional/three-dimensional EOS™ imaging is reliable and comparable to traditional X-ray imaging assessment of knee osteoarthritis aiding surgical management [J].
Hau, Melinda Yun Ting ;
Menon, Dipen Karunakar ;
Chan, Ronald Jing Ning ;
Chung, Kwong Yin ;
Chau, Wai Wang ;
Ho, Ki Wai .
KNEE, 2020, 27 (03) :970-979
[49]   Are Two- and Three-Dimensional Computed Tomographic Scan Measurements of Tibial Tubercle-Trochlear Groove Distance Equivalent? A Comparative Study [J].
Teo, Seow Hui ;
Ong, Teng Khiam ;
Merican, Azhar Mahmood ;
Hashim, Muhammad Sufian ;
Ng, Wuey Min ;
Al-Fayyadh, Mohamed Zubair Mohamed ;
Ali, Mohamed Razif Mohamed .
INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (06) :847-855
[50]   Two- and three-dimensional measurements of leg length change using an accelerometer-based portable navigation system in total hip arthroplasty [J].
Hasegawa, Masahiro ;
Naito, Yohei ;
Tone, Shine ;
Sudo, Akihiro .
BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)