Comparing inter- and intraobserver reliability between two-dimensional and three-dimensional measurements in the tibial component position of unicompartmental knee arthroplasty

被引:1
作者
Seki, Kazushige [1 ,3 ]
Seki, Toshihiro [1 ]
Siigi, Eiichi [2 ]
Imagama, Takashi [1 ]
Yamabe, Takamasa [1 ]
Sakai, Takashi [1 ]
机构
[1] Yamaguchi Univ, Dept Orthoped Surg, Grad Sch Med, Ube, Yamaguchi, Japan
[2] Yamaguchi Prefectural Grand Med Ctr, Dept Orthoped Surg, Hofu, Yamaguchi, Japan
[3] 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
来源
ACTA ORTHOPAEDICA BELGICA | 2023年 / 89卷 / 02期
关键词
unicompartmental knee arthroplasty; tibia; computed tomography; intra-and interobserver reliabilities; minimal detectable change; CLINICAL-OUTCOMES; ALIGNMENT; RADIOGRAPHS; AGREEMENT;
D O I
10.52628/89.2.10553
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In unicompartmental knee arthroplasty (UKA), the tibial component has a small coronal plane width, the tibia and tibial component rotations are mismatched, and the large tibial component posterior tilt may make accurate measurements of component positions difficult in radiography. The study aimed to assess the intra-and interobserver reliabilities of radiographic (2D) and 3D computed tomography (3D-CT) measurements and to determine the minimum detectable change (95% confidence level, MDC95) in the tibial component position measurements in UKA. The study included 23 females and 7 males. Two surgeons measured the tibial component position. Intraclass and interclass correlation coefficients (ICC) were calculated to obtain reliability, and Bland-Altman analysis was performed to assess systematic errors. The MDC95 was calculated according to MDC95 = standard error of measurement x 1.96 x root 2. In the 2D and 3D -CT measurements, intraobserver reliability for coronal and sagittal positions of the tibial component were sufficiently reliable, where ICCs were >0.8. In the coronal plane, the ICCs for interobserver reliability were lower in 2D (ICC, 0.5-0.7) than in 3D-CT (ICC > 0.9). Bland-Altman plots showed systematic bias in sagittal alignment in the 2D assessment. In the 3D assessment of intra-and interobserver reliability, the MDC95 of the coronal, sagittal, and axial planes was <2 degrees. In the 2D intra-and interobserver reliability, the MDC95 of the coronal and sagittal planes was >2 degrees. The 2D measurement had a risk of misidentifying the tibial component position in UKA.
引用
收藏
页码:316 / 325
页数:10
相关论文
共 50 条
  • [21] The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus
    Brunner, A.
    Honigmann, P.
    Treumann, T.
    Babst, R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 766 - 771
  • [22] A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements
    Nalcaci, R.
    Ozturk, F.
    Sokucu, O.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 100 - 106
  • [23] Three-dimensional kinematics of shoulder function in stroke patients: Inter- and intra-rater reliability
    Hansen, Gunhild M.
    Kersting, Uwe G.
    Pedersen, Asger R.
    Svendsen, Susanne W.
    Nielsen, Jorgen F.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 47 : 35 - 42
  • [24] Interobserver Reliability of Coronoid Fracture Classification: Two-Dimensional Versus Three-Dimensional Computed Tomography
    Lindenhovius, Anneluuk
    Karanicolas, Paul Jack
    Bhandari, Mohit
    van Dijk, Nick
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (09): : 1640 - 1646
  • [25] Comparison between two- and three-dimensional methods for offset measurements after total hip arthroplasty
    Tone, Shine
    Hasegawa, Masahiro
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Two- and three-dimensional evaluations following handheld robot-assisted total knee arthroplasty
    Tone, Shine
    Hasegawa, Masahiro
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [27] Inter-observer variation in two-dimensional and three-dimensional ultrasound measurement of papillary thyroid microcarcinoma
    Yan, Lin
    Ren, Ling
    Li, Yingying
    Luo, Yukun
    CANCER IMAGING, 2023, 23 (01)
  • [28] Is Valgus Cut Angle Based on Radiographic Measurements in Total Knee Arthroplasty Really Inaccurate? A Comparison of Two- and Three-Dimensional Measurements
    Liu, LiMing
    Lei, Kai
    Chen, Xin
    Fan, HuaQuan
    Yang, Liu
    Guo, Lin
    JOURNAL OF KNEE SURGERY, 2022, 35 (14) : 1563 - 1570
  • [29] The Validation of Two-Dimensional and Three-Dimensional Radiographic Measurements of Host Bone Coverage in Total Hip Arthroplasty for Hip Dysplasia: A Comparison with Intra-Operative Measurements
    Yon, Chang-Jin
    Lee, Kyung-Jae
    Choi, Byung-Chan
    Suh, Ho-Sung
    Min, Byung-Woo
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
  • [30] Intraobserver and interobserver reliability of cone beam weightbearing semi-automatic three-dimensional measurements in symptomatic pes cavovarus
    Bernasconi, Alessio
    Cooper, Lucy
    Lyle, Shirley
    Patel, Shelain
    Cullen, Nicholas
    Singh, Dishan
    Welck, Matthew
    FOOT AND ANKLE SURGERY, 2020, 26 (05) : 564 - 572