Comparing inter- and intraobserver reliability between two-dimensional and three-dimensional measurements in the tibial component position of unicompartmental knee arthroplasty

被引:0
|
作者
Seki, Kazushige [1 ,3 ]
Seki, Toshihiro [1 ]
Siigi, Eiichi [2 ]
Imagama, Takashi [1 ]
Yamabe, Takamasa [1 ]
Sakai, Takashi [1 ]
机构
[1] Yamaguchi Univ, Dept Orthoped Surg, Grad Sch Med, Ube, Yamaguchi, Japan
[2] Yamaguchi Prefectural Grand Med Ctr, Dept Orthoped Surg, Hofu, Yamaguchi, Japan
[3] 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
来源
ACTA ORTHOPAEDICA BELGICA | 2023年 / 89卷 / 02期
关键词
unicompartmental knee arthroplasty; tibia; computed tomography; intra-and interobserver reliabilities; minimal detectable change; CLINICAL-OUTCOMES; ALIGNMENT; RADIOGRAPHS; AGREEMENT;
D O I
10.52628/89.2.10553
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In unicompartmental knee arthroplasty (UKA), the tibial component has a small coronal plane width, the tibia and tibial component rotations are mismatched, and the large tibial component posterior tilt may make accurate measurements of component positions difficult in radiography. The study aimed to assess the intra-and interobserver reliabilities of radiographic (2D) and 3D computed tomography (3D-CT) measurements and to determine the minimum detectable change (95% confidence level, MDC95) in the tibial component position measurements in UKA. The study included 23 females and 7 males. Two surgeons measured the tibial component position. Intraclass and interclass correlation coefficients (ICC) were calculated to obtain reliability, and Bland-Altman analysis was performed to assess systematic errors. The MDC95 was calculated according to MDC95 = standard error of measurement x 1.96 x root 2. In the 2D and 3D -CT measurements, intraobserver reliability for coronal and sagittal positions of the tibial component were sufficiently reliable, where ICCs were >0.8. In the coronal plane, the ICCs for interobserver reliability were lower in 2D (ICC, 0.5-0.7) than in 3D-CT (ICC > 0.9). Bland-Altman plots showed systematic bias in sagittal alignment in the 2D assessment. In the 3D assessment of intra-and interobserver reliability, the MDC95 of the coronal, sagittal, and axial planes was <2 degrees. In the 2D intra-and interobserver reliability, the MDC95 of the coronal and sagittal planes was >2 degrees. The 2D measurement had a risk of misidentifying the tibial component position in UKA.
引用
收藏
页码:316 / 325
页数:10
相关论文
共 50 条
  • [1] Inter- and Intraobserver Reliability of Two-dimensional CT Scan for Total Knee Arthroplasty Component Malrotation
    Konigsberg, Beau
    Hess, Ryan
    Hartman, Curtis
    Smith, Lynette
    Garvin, Kevin L.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) : 212 - 217
  • [2] Three-dimensional finite element analysis of unicompartmental knee arthroplasty - the influence of tibial component inclination
    Sawatari, T
    Tsumura, H
    Iesaka, K
    Furushiro, Y
    Torisu, T
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (03) : 549 - 554
  • [3] Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty
    Osamu Tanifuji
    Tomoharu Mochizuki
    Hiroshi Yamagiwa
    Takashi Sato
    Satoshi Watanabe
    Hiroki Hijikata
    Hiroyuki Kawashima
    Knee Surgery & Related Research, 33
  • [4] Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty
    Tanifuji, Osamu
    Mochizuki, Tomoharu
    Yamagiwa, Hiroshi
    Sato, Takashi
    Watanabe, Satoshi
    Hijikata, Hiroki
    Kawashima, Hiroyuki
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [5] Three-Dimensional Finite Analysis of the Optimal Alignment of the Tibial Implant in Unicompartmental Knee Arthroplasty
    Sasatani, Katsumi
    Majima, Tokifumi
    Murase, Kohei
    Takeuchi, Naoki
    Matsumoto, Takeo
    Oshima, Yasushi
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (02) : 60 - 65
  • [6] A novel three-dimensional model for evaluation of unicompartmental knee prostheses tibial component positioning
    Julia Elisabeth Lenz
    Moritz Kaiser
    Volker Alt
    Michael Worlicek
    Philipp von Roth
    Archives of Orthopaedic and Trauma Surgery, 145 (1)
  • [7] Three-Dimensional Imaging Analysis of Unicompartmental Knee Arthroplasty Evaluated in Standing Position: Component Alignment and In Vivo Articular Contact
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Liow, Ming Han Lincoln
    Rubash, Harry E.
    Li, Guoan
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05): : 1096 - 1101
  • [8] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Hideki Ueyama
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Kazumasa Yamamura
    Suguru Nakamura
    Susumu Takemura
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1497 - 1503
  • [9] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Ueyama, Hideki
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Yamamura, Kazumasa
    Nakamura, Suguru
    Takemura, Susumu
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1497 - 1503
  • [10] Measurements From Image-Based Three Dimensional Pelvic Floor Reconstruction: A Study of Inter- and Intraobserver Reliability
    Hoyte, Lennox
    Brubaker, Linda
    Fielding, Julia R.
    Lockhart, Mark E.
    Heilbrun, Marta E.
    Salomon, Caryl G.
    Ye, Wen
    Brown, Morton B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (02) : 344 - 350