Research on the localization of pipe burst based on transient flow in a water supply network

被引:0
作者
Zheng, Guolei [1 ,2 ]
Tian, Yimei [1 ,4 ]
Li, Zhengxuan [1 ]
Cheng, Jing [1 ]
Liang, Jianwen [3 ]
Peng, Sen [1 ,4 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin, Peoples R China
[2] Univ Sci & Technol China, Sch Earth & Space Sci, Hefei, Peoples R China
[3] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
[4] Tianjin Univ, Sch Environm Sci & Engn, 135 Yaguan Rd, Haihe Educ Pk, Tianjin 300350, Peoples R China
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2024年 / 23卷 / 05期
基金
国家重点研发计划;
关键词
Water supply network; system abnormity; transient flow; pipe burst localization; abnormal features of water pressure; NATURAL-GAS PIPELINES; LEAK DETECTION; LOCATION; SYSTEMS; SINGLE; FRICTION; DESIGN; MODEL;
D O I
10.1177/14759217231209405
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Methods for determining pipe burst (PB) locations based on supervisory control and data acquisition systems (SCADAs) have been widely studied. Existing location methods either only detect PB areas or are only applied to relatively simple pipe networks. Thus, it is necessary to develop a PB localization method that can both accurately locate the PB and be used for complex pipe networks. Accordingly, in this study, a complex experimental pipe network with a high-frequency SCADA was built, and PB events were constructed under different conditions. After they were analyzed, the water pressure and flow anomalous features of the PBs were summarized. According to the propagation laws and damping theories of transient flow (TF), a PB localization method, that is, the TF simulation (TFS) method, was first proposed and developed after a TF model of the experimental pipe network was established. Using this method, two PB events were recognized, the burst pipes were identified, and the PBs were accurately located. Compared with the negative pressure wave method, the TFS method exhibits a higher location accuracy and a wider applicability to pipe networks. Through error analyses, it is shown that the TFS method has small errors. To reduce cost, the sampling frequency was decreased to 50 Hz, that is, the minimum required sampling frequency for this study, and under this condition, PB localization was successfully realized. An additional three PB localizations illustrate that they have acceptable errors and that the TFS method has good repeatability.
引用
收藏
页码:2679 / 2697
页数:19
相关论文
共 47 条
  • [1] Agbakwuru J., 1055, J ENVIRON PROT ECOL, V2
  • [2] Allievi L., 1925, RICCARDO GARONI ROME
  • [3] TRANSIENT BEHAVIOR OF SINGLE-PHASE NATURAL-CIRCULATION LOOP SYSTEMS
    ALSTAD, CD
    ISBIN, HS
    AMUNDSON, NR
    SILVERS, JP
    [J]. AICHE JOURNAL, 1955, 1 (04) : 417 - 425
  • [4] Andersen JH, 2001, INT J SYST SCI, V32, P807, DOI 10.1080/002077201750282007
  • [5] Angus RW., 1939, T ASCE, V104, P340
  • [6] Pipeline network features and leak detection by cross-correlation analysis of reflected waves
    Beck, SBM
    Curren, MD
    Sims, ND
    Stanway, R
    [J]. JOURNAL OF HYDRAULIC ENGINEERING, 2005, 131 (08) : 715 - 723
  • [7] A FULLY WELL-BALANCED, POSITIVE AND ENTROPY-SATISFYING GODUNOV-TYPE METHOD FOR THE SHALLOW-WATER EQUATIONS
    Berthon, Christophe
    Chalons, Christophe
    [J]. MATHEMATICS OF COMPUTATION, 2016, 85 (299) : 1281 - 1307
  • [8] Development of a Godunov-type model for the accurate simulation of dispersion dominated waves
    Bradford, Scott F.
    [J]. OCEAN MODELLING, 2016, 106 : 58 - 67
  • [9] Effect of rubber washers on leak location for assembled pressurized liquid pipeline based on negative pressure wave method
    Chen, Qiang
    Shen, Guodong
    Jiang, JunCheng
    Diao, Xu
    Wang, Zhirong
    Ni, Lei
    Dou, Zhan
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2018, 119 : 181 - 190
  • [10] Optimal sensor placement for leak location in water distribution networks: A feature selection method combined with graph signal processing
    Cheng, Menglong
    Li, Juan
    [J]. WATER RESEARCH, 2023, 242