LOW-COST THERMOCHROMIC QUALITY ASSURANCE PHANTOM FOR THERAPEUTIC ULTRASOUND DEVICES: A PROOF OF CONCEPT

被引:2
作者
Eames, Matt [1 ,2 ]
Larrabee, Zachary [1 ]
Hananel, Arik [1 ,2 ]
Padilla, Frederic [1 ,3 ]
Aubry, Jean-Francois [3 ,4 ,5 ]
机构
[1] Focused Ultrasound Fdn, Charlottesville, VA USA
[2] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA USA
[3] Univ Virginia, Sch Med, Dept Radiol, Charlottesville, VA USA
[4] PSL Res Univ, CNRS, INSERM, ESPCI Paris,Phys Med Paris,UMR8063,U1273, Paris, France
[5] Univ Virginia, Sch Med, Dept Radiol, 1215 Lee St, Charlottesville, VA 22908 USA
关键词
Therapeutics; System and device design; General physical acoustics; Medical transducers; INTENSITY-FOCUSED ULTRASOUND; RADIATION FORCE; ACOUSTIC POWER; SYSTEM; FEASIBILITY; FIELD; VEIN;
D O I
10.1016/j.ultrasmedbio.2022.09.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-intensity focused ultrasound (HIFU) transducer acoustic output can vary over time as a result of an inconsistent power supply, damage to the transducer or deterioration over time. Therefore, easy implementa-tion of a daily quality assurance (DQA) method is of great importance for pre-clinical research and clinical appli-cations. We present here a thermochromic material-based phantom validated by thermal simulations and found to provide repeatable visual power output assessments in fewer than 15 s that are accurate to within 10%. Whereas current available methods such as radiation force balance measurements provide an estimate of the total acoustic power, we explain here that the thermochromic phantom is sensitive to the shape of the acoustic field at focus by changing the aperture of a multi-element transducer with a fixed acoustic power. The proposed phantom allows the end user to visually assess the transducer's functionality without resorting to expensive, time-consuming hydrophone measurements or image analysis. (E-mail: jean-francois.aubry@espci.fr)& COPY; 2022 Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 46 条
[21]   The next generation of low-cost personal air quality sensors for quantitative exposure monitoring [J].
Piedrahita, R. ;
Xiang, Y. ;
Masson, N. ;
Ortega, J. ;
Collier, A. ;
Jiang, Y. ;
Li, K. ;
Dick, R. P. ;
Lv, Q. ;
Hannigan, M. ;
Shang, L. .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (10) :3325-3336
[22]   Assessments and application of low-cost sensors to study indoor air quality in layer facilities [J].
Afroz, Rowshon ;
Guo, Xinyang ;
Cheng, Chu-Wen ;
Omar, Sohaib ;
Carney, V. L. ;
Zuidhof, Martin J. ;
Zhao, Ran .
ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2024, 36
[23]   Review of low-cost self-driving laboratories in chemistry and materials science: the "frugal twin" concept [J].
Lo, Stanley ;
Baird, Sterling G. ;
Schrier, Joshua ;
Blaiszik, Ben ;
Carson, Nessa ;
Foster, Ian ;
Aguilar-Granda, Andres ;
Kalinin, Sergei V. ;
Maruyama, Benji ;
Politi, Maria ;
Tran, Helen ;
Sparks, Taylor D. ;
Aspuru-Guzik, Alan .
DIGITAL DISCOVERY, 2024, 3 (05) :842-868
[24]   Fully Integrated, Simple, and Low-Cost Electrochemical Sensor Array for in Situ Water Quality Monitoring [J].
Alam, Arif U. ;
Clyne, Dennis ;
Jin, Hao ;
Hu, Nan-Xing ;
Deen, M. Jamal .
ACS SENSORS, 2020, 5 (02) :412-422
[25]   Ripe or Rotten? Low-Cost Produce Quality Estimation Using Reflective Green Light Sensing [J].
Zuniga, Agustin ;
Flores, Huber ;
Nurmi, Petteri .
IEEE PERVASIVE COMPUTING, 2021, 20 (03) :60-67
[26]   Low-cost air quality monitoring networks for long-term field campaigns: A review [J].
Carotenuto, F. ;
Bisignano, A. ;
Brilli, L. ;
Gualtieri, G. ;
Giovannini, L. .
METEOROLOGICAL APPLICATIONS, 2023, 30 (06)
[27]   Nonlinear Regression Approach as a Correction Factor of Measurements of Low-Cost Electrochemical Air Quality Sensors [J].
Christakis, Ioannis ;
Tsakiridis, Odysseas ;
Sarri, Elena ;
Triantis, Dimos ;
Stavrakas, Ilias .
APPLIED SCIENCES-BASEL, 2024, 14 (08)
[28]   An Intelligent IoT-Based Food Quality Monitoring Approach Using Low-Cost Sensors [J].
Popa, Alexandru ;
Hnatiuc, Mihaela ;
Paun, Mirel ;
Geman, Oana ;
Hemanth, D. Jude ;
Dorcea, Daniel ;
Le Hoang Son ;
Ghita, Simona .
SYMMETRY-BASEL, 2019, 11 (03)
[29]   An economical fluorescence detector for lab-on-a-chip devices with a light emitting photodiode and a low-cost avalanche photodiode [J].
Wu, Jing ;
Liu, Xianhu ;
Wang, Lili ;
Dong, Lijun ;
Pu, Qiaosheng .
ANALYST, 2012, 137 (02) :519-525
[30]   A rapid, safe, and low-cost technique for the induction of mild therapeutic hypothermia in post-cardiac arrest patients [J].
Kory, Pierre ;
Weiner, Justin ;
Mathew, Joseph P. ;
Fukunaga, Mayuko ;
Palmero, Veronica ;
Singh, Bimaljeet ;
Haimowitz, Stephanie ;
Clark, Elana T. ;
Fischer, Alyssa ;
Mayo, Paul H. .
RESUSCITATION, 2011, 82 (01) :15-20