STROKE VOLUME VARIATION IS A GOOD PREDICTOR OF FLUID RESPONSIVENESS IN CARDIAC SURGERY PATIENTS WITH IMPLANTED INTRA-AORTIC BALLOON PUMP

被引:0
作者
Enev, Rostislav [1 ]
Abedinov, Fillip [1 ]
Bakalova, Neda [1 ]
Atanasova, Margarita [2 ]
Chilingirova, Nezabravka [3 ]
Krastev, Plamen [3 ]
机构
[1] Univ Hosp Sv Ekaterina, Clin Anesthesiol & Intens Care, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
[2] UMBAL Aleksandrovska, Anaesthesiol & Intens Care Dept, 1 St Georgi Sofiiski St, Sofia 1431, Bulgaria
[3] Univ Hosp Sv Ekaterina, Cardiol Clin, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
来源
COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES | 2023年 / 76卷 / 04期
关键词
stroke volume variation; fluid responsiveness; intra-aortic balloon pump;
D O I
10.7546/CRABS.2023.04.14
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 50 条
[41]   Air transfer of patients with intra-aortic balloon pump support Swiss experience and recommendations [J].
Berset, Andreas ;
Albrecht, Roland ;
Ummenhofer, Wolfgang ;
Erne, Jean-Jacques ;
Zuercher, Mathias .
SWISS MEDICAL WEEKLY, 2012, 142
[42]   Intra-aortic balloon pump use does not affect the renal function in patients undergoing off pump coronary artery bypass surgery [J].
Muniraju, Geetha ;
Pandey, Sourabh ;
Chakravarthy, Murali ;
Krishnamoorthy, Jayaprakash ;
Narayan, Sandeep ;
Jawali, Vivek .
ANNALS OF CARDIAC ANAESTHESIA, 2011, 14 (03) :188-191
[43]   Effectiveness of VA-ECMO plus intra-aortic balloon pump for cardiac shock in patients with type A aortic dissection: a case series [J].
Wu, Hui ;
Chen, Pengfei ;
Wei, Jinhua ;
Pei, Fengbo ;
Chen, Mingjian ;
Zhao, Diming ;
Wang, Liqing ;
Pu, Jundong ;
Chen, Zujun .
JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
[44]   Effectiveness of VA-ECMO plus intra-aortic balloon pump for cardiac shock in patients with type A aortic dissection: a case series [J].
Hui Wu ;
Pengfei Chen ;
Jinhua Wei ;
Fengbo Pei ;
Mingjian Chen ;
Diming Zhao ;
Liqing Wang ;
Jundong Pu ;
Zujun Chen .
Journal of Cardiothoracic Surgery, 18
[45]   Use of the intra-aortic ballon pump in cardiac surgery. Results of a nationwide questionnaire [J].
Marggraf, G. ;
Pilarczyk, K. .
ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2009, 23 (05) :288-292
[46]   Intra-Aortic Balloon Counterpulsation in High-Risk Cardiac Patients Undergoing Noncardiac Surgery: A Case Series [J].
Burgio, Gaetano ;
Martucci, Gennaro ;
Panarello, Giovanna ;
Scarlata, Maria ;
Pastore, Federico ;
Pilato, Michele ;
Scardulla, Cesare ;
Arcadipane, Antonio .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (02) :428-431
[47]   Characteristics, morbidity and mortality factors associated with Intra-Aortic Balloon Pump in Coronary Artery Bypass Graft Surgery patients [J].
Shah, Sayed Mumtaz Anwar ;
Awan, Nabil, I ;
Jan, Azam ;
Rehman, Mujeeb Ur .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (06) :1318-1324
[48]   Stroke Volume and Arterial Pressure Fluid Responsiveness in Patients With Elevated Stroke Volume Variation Undergoing Major Vascular Surgery: A Prospective Intervention Study [J].
Fischer, Arabella ;
Menger, Johannes ;
Mouhieddine, Mohamed ;
Seidel, Mathias ;
Edlinger-Stanger, Maximilian ;
Bevilacqua, Michele ;
Brugger, Jonas ;
Hiesmayr, Michael ;
Dworschak, Martin .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (03) :407-414
[49]   Pulse pressure variation and stroke volume variation predict fluid responsiveness in mechanically ventilated patients experiencing intra-abdominal hypertension [J].
Liu, Xiaomei ;
Fu, Qiang ;
Mi, Weidong ;
Liu, Henian ;
Zhang, Hong ;
Wang, Peiji .
BIOSCIENCE TRENDS, 2013, 7 (02) :101-108
[50]   Hemodynamic Evaluation of Intra-Aortic Dual-Balloon Pump Based on Fluid-Structure Interaction [J].
Ma, Hongchao ;
Wang, Yuhan ;
Gao, Bin ;
Li, Shu ;
Song, Zhiming ;
Chang, Yu ;
Zhang, Ran .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2025, 41 (01)