STROKE VOLUME VARIATION IS A GOOD PREDICTOR OF FLUID RESPONSIVENESS IN CARDIAC SURGERY PATIENTS WITH IMPLANTED INTRA-AORTIC BALLOON PUMP

被引:0
作者
Enev, Rostislav [1 ]
Abedinov, Fillip [1 ]
Bakalova, Neda [1 ]
Atanasova, Margarita [2 ]
Chilingirova, Nezabravka [3 ]
Krastev, Plamen [3 ]
机构
[1] Univ Hosp Sv Ekaterina, Clin Anesthesiol & Intens Care, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
[2] UMBAL Aleksandrovska, Anaesthesiol & Intens Care Dept, 1 St Georgi Sofiiski St, Sofia 1431, Bulgaria
[3] Univ Hosp Sv Ekaterina, Cardiol Clin, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
来源
COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES | 2023年 / 76卷 / 04期
关键词
stroke volume variation; fluid responsiveness; intra-aortic balloon pump;
D O I
10.7546/CRABS.2023.04.14
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 50 条
[31]   Clinical outcomes of the intra-aortic balloon pump for resuscitated patients with acute myocardial infarction complicated by cardiac arrest [J].
Kim, Hyun Kuk ;
Jeong, Myung Ho ;
Ahn, Youngkeun ;
Sim, Doo Sun ;
Chae, Shung Chull ;
Kim, Young Jo ;
Hur, Seung Ho ;
Seong, In Whan ;
Hong, Taek Jong ;
Choi, Dong Hoon ;
Cho, Myeong Chan ;
Kim, Chong Jin ;
Seung, Ki Bae ;
Jang, Yang Soo ;
Rha, Seung Woon ;
Bae, Jang Ho ;
Cho, Jeong Gwan ;
Park, Seung Jung .
JOURNAL OF CARDIOLOGY, 2016, 67 (1-2) :57-63
[32]   Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation [J].
Suehiro, K. ;
Rinka, H. ;
Ishikawa, J. ;
Fuke, A. ;
Arimoto, H. ;
Miyaichi, T. .
ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) :767-772
[33]   Elective Use of Intra-Aortic Balloon Pump During Aortic Valve Replacement in Elderly Patients to Reduce Postoperative Cardiac Complications [J].
Nakahira, Junko ;
Sawai, Toshiyuki ;
Minami, Toshiaki .
ARTIFICIAL ORGANS, 2014, 38 (06) :503-507
[34]   Vascular Complications of the Intra-aortic Balloon Pump in Patients Undergoing Open Heart Surgery: 10 Years' Experience [J].
Yuksel, Volkan ;
Huseyin, Serhat ;
Ozdemir, Ahmet Coskun ;
Ege, Turan .
THORACIC AND CARDIOVASCULAR SURGEON, 2013, 61 (05) :453-455
[35]   Early outcomes of Intra-Aortic Balloon Pump in Patients Undergoing Coronary Artery Bypass Grafting (CABG) Surgery [J].
Farogh, Ajwad ;
Bashir, Gohar ;
Gull, Saira ;
Ahmad, Naseem ;
Hassan, Asama ;
Waqas, Hafiz M. ;
Afshan, Shamila .
PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (09) :2422-2424
[36]   Utility of intra-aortic balloon pump support for multivessel coronary artery spasm and cardiac arrest [J].
Zhang, Zhiping ;
Su, Xi ;
Liu, Chengwei ;
Xu, Chengyi ;
Wu, Mingxiang ;
Yang, Yuchun ;
Liu, Bo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) :E122-E124
[37]   Analysis of clinical outcomes of intra-aortic balloon pump during coronary artery bypass surgery [J].
Yumun, Gunduz ;
Aydin, Ufuk ;
Ata, Yusuf ;
Toktas, Faruk ;
Pala, Arda Aybars ;
Ozyazicioglu, Ahmet Fatih ;
Turk, Tamer ;
Yavuz, Senol .
CARDIOVASCULAR JOURNAL OF AFRICA, 2015, 26 (03) :130-133
[38]   Vascular complications of prolonged intra-aortic balloon counterpulsation in cardiac surgical patients [J].
Meharwal Z.S. ;
Choudhary A. ;
Trehan N. .
Indian Journal of Thoracic and Cardiovascular Surgery, 2002, 18 (2) :75-79
[39]   Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients [J].
Christenson, JT ;
Simonet, F ;
Badel, P ;
Schmuziger, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (06) :1097-1103
[40]   von Willebrand factor and bleeding complication in patients treated with intra-aortic balloon pump [J].
Zhong, Hua ;
Zhu, Zhaowei ;
Tang, Jianjun .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 214 :483-483