STROKE VOLUME VARIATION IS A GOOD PREDICTOR OF FLUID RESPONSIVENESS IN CARDIAC SURGERY PATIENTS WITH IMPLANTED INTRA-AORTIC BALLOON PUMP

被引:0
作者
Enev, Rostislav [1 ]
Abedinov, Fillip [1 ]
Bakalova, Neda [1 ]
Atanasova, Margarita [2 ]
Chilingirova, Nezabravka [3 ]
Krastev, Plamen [3 ]
机构
[1] Univ Hosp Sv Ekaterina, Clin Anesthesiol & Intens Care, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
[2] UMBAL Aleksandrovska, Anaesthesiol & Intens Care Dept, 1 St Georgi Sofiiski St, Sofia 1431, Bulgaria
[3] Univ Hosp Sv Ekaterina, Cardiol Clin, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
来源
COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES | 2023年 / 76卷 / 04期
关键词
stroke volume variation; fluid responsiveness; intra-aortic balloon pump;
D O I
10.7546/CRABS.2023.04.14
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 50 条
[21]   Acute haemodynamic effects of intra-aortic balloon pump and cardiac resynchronization therapy [J].
Bonanno, Carlo ;
Ometto, Renato ;
La Vecchia, Luigi ;
Fontanelli, Alessandro .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (07) :719-724
[22]   Intra-aortic balloon pump for hemodynamic support in hepatobiliary surgery: report of a case [J].
Resnick, Shelby ;
Matsuoka, Lea ;
Cesario, David ;
Darwish, Ahmed ;
Selby, R. Rick ;
Sher, Linda .
SURGERY TODAY, 2012, 42 (08) :793-796
[23]   Intra-aortic balloon pump for hemodynamic support in hepatobiliary surgery: report of a case [J].
Shelby Resnick ;
Lea Matsuoka ;
David Cesario ;
Ahmed Darwish ;
R. Rick Selby ;
Linda Sher .
Surgery Today, 2012, 42 :793-796
[24]   Preoperative intra-aortic balloon pump in patients with ST-elevation myocardial infarction undergoing urgent cardiac bypass surgery [J].
Hemradj, Veemal V. ;
Spanjersberg, Alexander J. ;
Buitenhuis, Marit ;
Markou, Thanasie ;
Hermanides, Rik S. ;
Dambrink, Jan-Henk ;
Gosselink, Marcel ;
Roolvink, Vincent ;
van Leeuwen, Maarten ;
Ottervanger, Jan Paul .
NETHERLANDS HEART JOURNAL, 2024, 32 (7-8) :276-282
[25]   Volume-Outcome Relationships for Intra-Aortic Balloon Pump in Acute Myocardial Infarction [J].
Saito, Yuichi ;
Tateishi, Kazuya ;
Kanda, Masato ;
Shiko, Yuki ;
Kawasaki, Yohei ;
Kobayashi, Yoshio ;
Inoue, Takahiro .
CIRCULATION JOURNAL, 2024, 88 (08) :1286-1292
[26]   Unveiling the hidden risk: a case of severe jaundice triggered by intra-aortic balloon pump after cardiac surgery [J].
Wang, Han ;
Chen, Zerui ;
Lei, Liming ;
Fang, Miaoxian .
JOURNAL OF CARDIOTHORACIC SURGERY, 2025, 20 (01)
[27]   Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery [J].
Li, Cheng ;
Lin, Fu-qing ;
Fu, Shu-kun ;
Chen, Guo-qiang ;
Yang, Xiao-hu ;
Zhu, Chun-yan ;
Zhang, Li-jun ;
Li, Quan .
INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2013, 10 (02) :148-155
[28]   Comparative study of pressure- and volume-controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients undergoing major abdominal surgery [J].
Lee, Ji Yeon ;
Park, Hee Yeon ;
Jung, Wol Seon ;
Jo, Youn Yi ;
Kwak, Hyun Jeong .
JOURNAL OF CRITICAL CARE, 2012, 27 (05) :531.e9-531.e14
[29]   Preoperative Intra-Aortic Balloon Pumps in Cardiac Surgery: A Propensity Score Analysis [J].
Ali, Umar S. ;
Lan, Nick S. R. ;
Gilfillan, Molly ;
Ho, Kwok ;
Pavey, Warren ;
Dwivedi, Girish ;
Slimani, Eric K. ;
Edelman, James ;
Merry, Chris ;
Larbalestier, Robert .
HEART LUNG AND CIRCULATION, 2021, 30 (05) :758-764
[30]   Successful surgery for perforation of the thoracic aorta caused by the tip of an intra-aortic balloon pump [J].
Wolff, T ;
Stulz, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (06) :1176-1179