STROKE VOLUME VARIATION IS A GOOD PREDICTOR OF FLUID RESPONSIVENESS IN CARDIAC SURGERY PATIENTS WITH IMPLANTED INTRA-AORTIC BALLOON PUMP

被引:0
|
作者
Enev, Rostislav [1 ]
Abedinov, Fillip [1 ]
Bakalova, Neda [1 ]
Atanasova, Margarita [2 ]
Chilingirova, Nezabravka [3 ]
Krastev, Plamen [3 ]
机构
[1] Univ Hosp Sv Ekaterina, Clin Anesthesiol & Intens Care, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
[2] UMBAL Aleksandrovska, Anaesthesiol & Intens Care Dept, 1 St Georgi Sofiiski St, Sofia 1431, Bulgaria
[3] Univ Hosp Sv Ekaterina, Cardiol Clin, 52A P Slaveykov Blvd, Sofia 1431, Bulgaria
来源
COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES | 2023年 / 76卷 / 04期
关键词
stroke volume variation; fluid responsiveness; intra-aortic balloon pump;
D O I
10.7546/CRABS.2023.04.14
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 50 条
  • [1] A survey on the use of intra-aortic balloon pump in cardiac surgery
    Bignaini, Elena
    Tritapepe, Luigi
    Pasin, Laura
    Meroni, Roberta
    Corno, Laura
    Testa, Valentina
    Landoni, Giovanni
    Guarracino, Fabio
    Zangrillo, Alberto
    ANNALS OF CARDIAC ANAESTHESIA, 2012, 15 (04) : 274 - +
  • [2] Levosimendan Versus an Intra-aortic Balloon Pump in Adult Cardiac Surgery Patients With Low Cardiac Output
    Elahi, Maqsood M.
    Lam, Jimmy
    Asopa, Sanjay
    Matata, Bashir M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1154 - 1162
  • [3] Complications related to intra-aortic balloon pump in cardiac surgery: A decade later
    Elahi, MM
    Chetty, GK
    Kirke, R
    Azeem, T
    Hartshorne, R
    Spyt, TJ
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 29 (06) : 591 - 594
  • [4] Levosimendan Versus Intra-aortic Balloon Pump in High-Risk Cardiac Surgery Patients
    Severi, Luca
    Lappa, Angela
    Landoni, Giovanni
    Di Pirro, Lucio
    Luzzi, Sacha Jerome
    Caravetta, Patrizia
    Cipullo, Pierluigi
    Menichetti, Antonio
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (04) : 632 - 636
  • [5] Is heparin needed for patients with an intra-aortic balloon pump?
    Pucher, Philip H.
    Cummings, Ian G.
    Shipolini, Alex R.
    McCormack, David J.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (01) : 136 - 139
  • [6] Intra-aortic balloon pump postcardiac surgery: A literature review
    Jannati, Mansour
    Attar, Armin
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2019, 24
  • [7] Pressure controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients
    Ye, Weiguang
    Wang, Bin
    Wei, Limin
    Wang, Tianlong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10963 - 10970
  • [8] Efficacy of Prophylactic Intra-Aortic Balloon Pump Therapy in Chronic Heart Failure Patients Undergoing Cardiac Surgery
    Yildirim, Yalin
    Pecha, Simon
    Kubik, Mathias
    Alassar, Yousuf
    Deuse, Tobias
    Hakmi, Samer
    Reichenspurner, Hermann
    ARTIFICIAL ORGANS, 2014, 38 (11) : 967 - 972
  • [9] Clinical application of intra-aortic balloon pump in patients with cardiogenic shock during the perioperative period of cardiac surgery
    Jiang, Xuesong
    Zhu, Zhitao
    Ye, Ming
    Yan, Yan
    Zheng, Junbo
    Dai, Qingqing
    Wen, Lianghe
    Wang, Huaiquan
    Lou, Shaofei
    Ma, Hongmei
    Ma, Pingwei
    Li, Yunlong
    Yang, Tuoyun
    Zuo, Shu
    Tian, Ye
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (05) : 1741 - 1748
  • [10] Accuracy of stroke volume variation as a predictor of volume responsiveness in patients with raised intra-abdominal pressure
    WO Bauer
    M Cecconi
    A Rhodes
    W Bernal
    J Wendon
    G Auzinger
    Critical Care, 15 (Suppl 1):