Related Substances Method Development and Validation of Axitinib, Zanubrutinib and Upadacitinib Using RP-HPLC and its Degradation Products were Characterized by Using LC-MS/MS

被引:3
作者
Syed, Ibrahim Baje [1 ]
Nannapaneni, Madhavi [1 ,2 ]
机构
[1] Acharya Nagarjuna Univ, JKC Coll Guntur, Dept Chem, Guntur, Andhra Pradesh, India
[2] Acharya Nagarjuna Univ, JKC Coll, Dept Chem, Guntur 522510, Andhra Pradesh, India
关键词
Mobile phase; X-bridge column; Validation; ICH guidelines; ANGIOGENESIS; INHIBITORS; AG-013736; GROWTH;
D O I
10.5530/223097131696
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Axitinib was used to treat carcinoma of renal cells and Upadacitinib was used to treat rheumatoid arthritis and Zanubrutinib used as an anti cancer medication for mantle cell lymphoma. In the current application, Zanubrutinib, Upadacitinib and Axitinib and their associated substances will be developed and validated. Materials and Methods: The optimised method includes the Zanubrutinib, Upadacitinib and Axitinib gradient elution and associated flow rates with dimensions of 1 mL/min and phenyl column X-bridge (150 x 4.6 mm, 3.5 mu). A mobile phase was employed with 1.2 g of Hexane sulphonic acid of pH-2.5 adjusted with ortho-phosphoric acid (buffer) and acetonitrile. Zanubrutinib, Upadacitinib and Axitinib were separated from their associated substances for a total run time of 60 min. The approach developed has been validated in accordance with the ICH guidelines. Results: The test concentration LOD and LOQ were established for both drugs and for their impurities. The diagrams that were drawn were straightforward with an R2 regression coefficient > 0.999. As part of the method validation, recovery, specificity, linearity, accuracy, robustness was determined and the results were found to be within an acceptable range. Conclusion: HPLC was used to validate the method in terms of accuracy, linearity, method precision, accuracy, limit of detection, limit of quantification, robustness, and degradation, and LC-MS/MS was used to characterise the degradation products. The system was validated in all of these aspects.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [41] Determination of cocaine, its metabolites and pyrolytic products by LC-MS using a chemometric approach
    Pereira, Andrea Garcia
    D'Avila, Felipe Bianchini
    Lukasewicz Ferreira, Pamela C.
    Holler, Marcelo Gatteli
    Limberger, Renata Pereira
    Froeehlich, Pedro Eduardo
    ANALYTICAL METHODS, 2014, 6 (02) : 456 - 462
  • [42] Forced degradation studies and development of RP-HPLC method for related substances of Tenofovir alafenamide in tablet dosage form
    Patel, Binal N.
    Vekaria, Hitesh J.
    ANALYTICAL CHEMISTRY LETTERS, 2023, 13 (03) : 321 - 336
  • [43] Determination of 16 Hydroxyanthracene Derivatives in Food Supplements Using LC-MS/MS: Method Development and Application
    Malysheva, Svetlana V.
    Guillaume, Benoit
    Vanhee, Celine
    Masquelier, Julien
    TOXINS, 2024, 16 (12)
  • [44] BIO ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF TEMOZOLOMIDE IN RAT PLASMA USING RP-HPLC METHOD
    Pallerla, Swathimutyam
    Prabhakar, Bala
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (03): : 1298 - 1301
  • [45] Development, Validation and Forced Degradation Study of Emtricitabine and Tenofovir Alafenamide in its Pharmaceutical Dosage Form Using RP-HPLC
    Patel, Khushboo
    Shah, Ujashkumar
    Joshi, Hirak
    Patel, Jayvadan K.
    Patel, Tejas B.
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (43A) : 37 - 46
  • [46] Development and validation of a LC-MS/MS method for simultaneous determination of six glucocorticoids and its application to a pharmacokinetic study in nude mice
    Yao, Qingyu
    Guo, Yuchen
    Xue, Junsheng
    Kong, Daming
    Li, Jian
    Tian, Xiuyun
    Hao, Chunyi
    Zhou, Tianyan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 179
  • [47] Development and validation of bexarote by bioanalytical methods using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    K. Nagaraju
    Y. A. Chowdary
    M. V. Basaveswara Rao
    Future Journal of Pharmaceutical Sciences, 7
  • [48] Development and validation of bexarote by bioanalytical methods using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Nagaraju, K.
    Chowdary, Y. A.
    Rao, M. V. Basaveswara
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 7 (01)
  • [49] Simultaneous determination and determination of sildenafil and its active metabolite in human plasma using LC-MS/MS method
    Li, Lin-ling
    Zhang, Xiu-jin
    Zheng, Chao
    Fan, Ming-xia
    Xu, Hao-yun
    Yi, Jin-ling
    Feng, Yan
    Luo, Xi
    Li, Wei-hua
    Cheng, Ze-neng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [50] Method validation studies and an inter-laboratory cross validation study of lenvatinib assay in human plasma using LC-MS/MS
    Mano, Yuji
    PRACTICAL LABORATORY MEDICINE, 2018, 12