Life cycle cost and environmental assessment of CO2 utilization in the beverage industry: A natural gas-fired power plant equipped with post-combustion CO2 capture

被引:11
|
作者
Hosseini, Seyed Mohsen [1 ]
Aslani, Alireza [1 ,2 ]
Kasaeian, Alibakhsh [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
[2] Univ Tehran, Fac New Sci & Technol, North Kargar St, Tehran, Iran
关键词
Life cycle assessment; Natural gas power plant; CO2 capture and utilization; Soft drinks; CARBON-DIOXIDE; STORAGE;
D O I
10.1016/j.egyr.2022.11.200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Besat is a natural gas-fired steam-turbine power plant in Tehran, Iran's only power station equipped with a monoethanolamine-based post-combustion CO2 capture unit (PCCU). The PCCU operates at a low recovery rate of 4.7% and produces 58 t-CO2/day. Captured CO2 is encapsulated and sold to beverage companies for carbonated soft drink production. Before developing this CO2 capture and utilization (CCU) route, a beverage company like ZamZam produced CO2 on-site, capturing CO2 from flue gas of diesel-fired boilers using a 95%-efficient absorption-refrigeration unit. This paper conducts an attributional, comparative life-cycle assessment/costing of applying the CCU technology to supply the beverage industry with CO2. ReCiPe, cumulative energy demand, and AWARE impact assessment methods are adopted to assess changes in the life-cycle economic, energy, and environmental impacts of electricity, liquid CO2, and carbonated water supply chains with the CCU route. As per findings, the CCU route significantly improves the sustainability profile of liquid CO2 supply for carbonated water production. Compared to on-site production, the CCU route reduces the average economic, energy, and environmental impacts of liquid CO2 supply by 55, 44, and 62%, respectively. However, the figures for carbonated-water production are reduced by only 10.1, 0.85, and 0.77%, respectively, since associated impacts primarily result from citric acid and polyethylene terephthalate value chains rather than liquid CO2. The CCU route, in comparison, increases most environmental burdens of electricity generation. With an efficiency of 4.7%, the PCCU reduces the global warming potential of electricity generation by 6.22% while increasing average toxicity-and eutrophication-related impacts by 55 and 30%, respectively, and production costs by 8%.
引用
收藏
页码:414 / 436
页数:23
相关论文
共 50 条
  • [11] Life cycle assessment of natural gas combined cycle integrated with CO2 post combustion capture using chemical solvent
    Fadeyi, Stephen
    Arafat, Hassan A.
    Abu-Zahra, Mohammad R. M.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2013, 19 : 441 - 452
  • [12] Thermodynamic analysis of combined cycle gas turbine power plant with post-combustion CO2 capture and exhaust gas recirculation
    Canepa, Roberto
    Wang, Meihong
    Biliyok, Chechet
    Satta, Antonio
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2013, 227 (E2) : 89 - 105
  • [13] Performance viability of a natural gas fired combined cycle power plant integrated with post-combustion CO2 capture at part-load and temporary non-capture operations
    Rezazadeh, Fatemeh
    Gale, William F.
    Hughes, Kevin J.
    Pourkashanian, Mohamed
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2015, 39 : 397 - 406
  • [14] Life cycle assessment of post-combustion CO2 capture: A comparison between membrane separation and chemical absorption processes
    Giordano, Lorena
    Roizard, Denis
    Favre, Eric
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 68 : 146 - 163
  • [15] A Comparative of Life Cycle Assessment of Post-Combustion, Pre-Combustion and Oxy-fuel CO2 capture
    Zhou, Q.
    Koiwanit, J.
    Piewkhaow, L.
    Manuilova, A.
    Chan, C. W.
    Wilson, M.
    Tontiwachwuthikul, P.
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 7452 - 7458
  • [16] Energetic Evaluation of Different Flow Sheet Modifications of Post-Combustion CO2 Capture Plant at Coal and Natural Gas Fired Power Plant for a Generic Improved Solvent
    Ehlers, Soeren
    Roeder, Volker
    Kather, Alfons
    Singh, Prachi
    Davison, John
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 1029 - 1039
  • [17] Life-cycle performance of natural gas power plants with pre-combustion CO2 capture
    Petrakopoulou, Fontina
    Iribarren, Diego
    Dufour, Javier
    GREENHOUSE GASES-SCIENCE AND TECHNOLOGY, 2015, 5 (03): : 268 - 276
  • [18] Membrane properties required for post-combustion CO2 capture at coal-fired power plants
    Roussanaly, Simon
    Anantharaman, Rahul
    Lindqvist, Karl
    Zhai, Haibo
    Rubin, Edward
    JOURNAL OF MEMBRANE SCIENCE, 2016, 511 : 250 - 264
  • [19] Life cycle modelling and comparative assessment of the environmental impacts of oxy-fuel and post-combustion CO2 capture, transport and injection processes
    Nie, Zhenggang
    Korre, Anna
    Durucan, Sevket
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 2510 - 2517
  • [20] A Review of Post-combustion CO2 Capture Technologies from Coal-fired Power Plants
    Wang, Yuan
    Zhao, Li
    Otto, Alexander
    Robinius, Martin
    Stolten, Detlef
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 650 - 665