Comparison of Flow-Redirection Endoluminal Device and Pipeline Embolization Device in the Treatment of Intracerebral Aneurysms

被引:14
|
作者
El Naamani, Kareem [1 ]
Saad, Hassan [2 ]
Chen, Ching-Jen [1 ]
Abbas, Rawad [1 ]
Sioutas, Georgios S. [1 ]
Amllay, Abdelaziz [1 ]
Yudkoff, Clifford J. [1 ]
Carreras, Angeleah [1 ]
Sambangi, Abhijeet [1 ]
Hunt, Adam [1 ]
Jain, Paarth [1 ]
Dougherty, Jaime [1 ]
Tjoumakaris, Stavropoula I. [1 ]
Gooch, Michael R. [1 ]
Herial, Nabeel A. [1 ]
Rosenwasser, Robert H. [1 ]
Zarzour, Hekmat [1 ]
Schmidt, Richard F. [1 ]
Jabbour, Pascal M. [1 ,3 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Neurol Surg, Philadelphia, PA 19107 USA
[2] Emory Univ, Dept Neurosurg, Atlanta, GA USA
[3] Thomas Jefferson Univ Hosp, Dept Neurol Surg, Div Chief Neurovasc Surg & Endovascular Neurosurg, 901 Walnut St 3rd Floor, Philadelphia, PA 19107 USA
关键词
FRED; Pipeline; Flow diversion; Aneurysms; Comparison; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; MULTICENTER; SAFETY; EXPERIENCE; RECURRENCE; DIVERTORS; EFFICACY; STENT;
D O I
10.1227/neu.0000000000002148
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The use of flow diverters for treating intracranial aneurysms has been widely used in the past decade; however, data comparing pipeline embolization device (PED; Medtronic Inc) and flow-redirection endoluminal device (FRED; MicroVention) in the treatment of intracranial aneurysms remain scarce. OBJECTIVE: To compare the outcomes of PED and FRED in the treatment of intracranial aneurysms. METHODS: This is a single-center retrospective review of aneurysms treated with PED and FRED devices. Patients treated with PED or FRED were included. Cases requiring multiple or adjunctive devices were excluded. Primary outcome was complete aneurysm occlusion at 6 months. Secondary outcomes included good functional outcome, need for retreatment, and any complication. RESULTS: The study cohort comprised 150 patients, including 35 aneurysms treated with FRED and 115 treated with PED. Aneurysm characteristics including location and size were comparable between the 2 cohorts. 6-month complete occlusion rate was significantly higher in the PED cohort (74.7% vs 51.5%; P = .017) but lost significance after inverse probability weights. Patients in the PED cohort were associated with higher rates of periprocedural complications (3.5% vs 0%; P = .573), and the rate of in-stent stenosis was approximately double in the FRED cohort (15.2% vs 6.9%; P = .172). CONCLUSION: Compared with PED, FRED offers modest 6-month occlusion rates, which may be due to aneurysmal and baseline patient characteristics differences between both cohorts. Although not significant, FRED was associated with a higher complication rate mostly because of in-stent stenosis. Additional studies with longer follow-up durations should be conducted to further evaluate FRED thrombogenicity.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 50 条
  • [21] Flow Redirection Endoluminal Device (FRED) with or without Adjunctive Coiling in Treatment of Very Large and Giant Cerebral Aneurysms
    Kandemirli, Sedat Giray
    Baltacioglu, Feyyaz
    Jesser, Jessica
    Kizilkilic, Osman
    Islak, Civan
    Mohlenbruch, Markus
    Kocer, Naci
    CLINICAL NEURORADIOLOGY, 2022, 32 (02) : 471 - 480
  • [22] Treatment of Blister-Like Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Zanaty, Mario
    Tjoumakaris, Stavropoula
    Gonzalez, L. Fernando
    Hasan, David
    Kung, David
    Rosenwasser, Robert H.
    Jabbour, Pascal
    NEUROSURGERY, 2014, 74 (05) : 527 - 532
  • [23] Endovascular treatment of fusiform cerebral aneurysms with the Pipeline Embolization Device
    Monteith, Stephen J.
    Tsimpas, Asterios
    Dumont, Aaron S.
    Tjoumakaris, Stavropoula
    Gonzalez, L. Fernando
    Rosenwasser, Robert H.
    Jabbour, Pascal
    JOURNAL OF NEUROSURGERY, 2014, 120 (04) : 945 - 954
  • [24] Aneurysms with persistent patency after treatment with the Pipeline Embolization Device
    Kan, Peter
    Srinivasan, Visish M.
    Mbabuike, Nnenna
    Tawk, Rabih G.
    Ban, Vin Shen
    Welch, Babu G.
    Mokin, Maxim
    Mitchell, Bartley D.
    Puri, Ajit
    Binning, Mandy J.
    Duckworth, Edward
    JOURNAL OF NEUROSURGERY, 2017, 126 (06) : 1894 - 1898
  • [25] Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
    Phillips, T. J.
    Wenderoth, J. D.
    Phatouros, C. C.
    Rice, H.
    Singh, T. P.
    Devilliers, L.
    Wycoco, V.
    Meckel, S.
    McAuliffe, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) : 1225 - 1231
  • [26] Mortality after treatment of intracranial aneurysms with the Pipeline Embolization Device
    Kang, Huibin
    Luo, Bin
    Liu, Jianmin
    Zhang, Hongqi
    Li, Tianxiao
    Song, Donglei
    Zhao, Yuanli
    Guan, Sheng
    Maimaitili, Aisha
    Wang, Yunyan
    Feng, Wenfeng
    Wang, Yang
    Wan, Jieqing
    Mao, Guohua
    Shi, Huaizhang
    Wang, Kun
    Yang, Xinjian
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (01) : 46 - +
  • [27] Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device
    Chalouhi, Nohra
    Chitale, Rohan
    Starke, Robert M.
    Jabbour, Pascal
    Tjoumakaris, Stavropoula
    Dumont, Aaron S.
    Rosenwasser, Robert H.
    Gonzalez, L. Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (01) : 19 - 23
  • [28] Commentary: The Pennsylvania Postmarket Multicenter Experience With Flow Redirection Endoluminal Device
    Restrepo, Andres F.
    Singer, Justin
    NEUROSURGERY, 2022, 91 (04) : E109 - E110
  • [29] Treatment of Posterior Circulation Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Tjoumakaris, Stavropoula
    Dumont, Aaron S.
    Gonzalez, L. Fernando
    Randazzo, Ciro
    Starke, Robert M.
    Rosenwasser, Robert H.
    Jabbour, Pascal
    NEUROSURGERY, 2013, 72 (06) : 883 - 889
  • [30] Retreatment of previously flow diverted intracranial aneurysms with the pipeline embolization device
    Lauzier, David C.
    Cler, Samuel J.
    Chatterjee, Arindam R.
    Osbun, Joshua W.
    Moran, Christopher J.
    Kansagra, Akash P.