Adverse events related to accessory devices used during ureteroscopy: Findings from a 10-year analysis of the Manufacturer and User Facility Device Experience (MAUDE) database

被引:3
|
作者
Juliebo-Jones, Patrick [1 ,2 ,3 ]
Somani, Bhaskar K. [4 ]
Mykoniatis, Ioannis [3 ,5 ]
Hameed, B. M. Zeeshan [3 ,6 ]
Tzelves, Lazaros [3 ,7 ]
Aesoy, Mathias S. [1 ]
Gjengsto, Peder [1 ]
Moen, Christian Arvei [1 ]
Beisland, Christian [1 ,2 ]
Ulvik, Oyvind [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Urol, Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] EAU YAU Urolithiasis Grp, Arnhem, Netherlands
[4] Univ Hosp Southampton, Dept Urol, Southampton, England
[5] Aristotle Univ Thessaloniki, Fac Hlth Sci, Sch Med, Dept Urol, Thessaloniki, Greece
[6] Father Muller Med Coll, Dept Urol, Mangalore, Karnataka, India
[7] Natl & Kapodistrian Univ Athens, Sismanogleio Gen Hosp, Dept Urol 2, Athens, Greece
来源
BJUI COMPASS | 2024年 / 5卷 / 01期
关键词
basket; ureteral access sheath; ureteroscopy; urolithiasis;
D O I
10.1002/bco2.274
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesThe objective of this study was to evaluate adverse events and device events related to accessories used during ureteroscopy (URS).Materials and methodsAnalysis was performed of the records available in the Manufacturer and User Facility Device Experience database in the United States. Information was collected on characteristics of problem, timing, manufacturer verdict, successful completion of planned surgery, prolonged anaesthesia and injury to patient or staff.ResultsFive-hundred seventy-one events related to URS accessories were recorded. These were associated with the following devices: baskets (n = 347), access sheath (n = 86), guidewires (n = 78), balloon dilators (n = 27), ARDs (n = 17) and ureteral catheters (n = 16). Of the events, 12.7% resulted in patient injuries. Forty-eight per cent of the events resulted in prolonged anaesthesia, but the planned surgery was successfully completed in 78.4% of all cases. Collectively, the manufacturers accepted responsibility due to actual device failure in only 0.5% of cases. Common problems for baskets were failure to deploy (39.5%) and complete detachment of basket head (34.6%) and partial breakage of the basket head (12.4%). Of the basket group, 4.3% required open or percutaneous surgery to remove stuck basket. Full break of the body of the access sheath occurred in 41.9% and complete ureteral avulsion in 3.5%. For balloon dilators, there was a burst in 37% of cases. Broken guidewires were associated with 11.5% requiring repeat intervention for retrieval and 6.4% required JJ stent due to perforation to the collecting system. No injuries to operating staff were recorded with accessory usage.ConclusionAccessories used during URS are fragile. Potential for serious injury does exist as a direct result of their use. Surgeons should familiarise themselves with these events and how they can be prevented.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [21] Adverse Events Related to Impella CP and Impella 5.5 from the Manufacturer and User Facility Device Experience Database
    Matai, P.
    Amirian, A.
    Khadka, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [22] ADVERSE EVENTS RELATED TO IMPELLA 5.0 AND IMPELLA 5.5 FROM THE MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE DATABASE
    Debenham, Rachel
    Rajapreyar, Indranee
    Alvarez, Rene J., Jr.
    Rame, Jesus Eduardo
    Entwistle, John, III
    Massey, Howard Todd
    Tchantchaleishvili, Vakhtang
    Plestis, Konstadinos
    Shah, Mahek
    Brailovsky, Yevgeniy
    Fischman, David L.
    Ruggiero, Nicholas J., II
    Savage, Michael P.
    Mehrotra, Praveen
    Gnall, Eric
    Vishnevsky, Alec
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 487 - 487
  • [23] Adverse Events After Left Atrial Appendage Closure: Lessons Learned From the Manufacturer and User Facility Device Experience (MAUDE) Database
    Singh, Swaiman
    Okoh, Alexis
    Sossou, Christoph
    Heaton, Joseph
    Sandhu, Mayal
    Chakrabarti, Ritu
    Rao, Rameez
    Tayal, Rajiv
    Wasty, Najam
    Waxman, Sergio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B113 - B113
  • [24] Adverse Events After Left Atrial Appendage Closure: Lessons Learned From the Manufacturer and User Facility Device Experience (MAUDE) Database
    Heaton, Joseph
    Okoh, Alexis K.
    Sossou, Christoph
    Singh, Swaiman
    Sandhu, Mayal
    Chakrabarti, Ritu
    Rao, Rameez
    Waxman, Sergio
    Tayal, Rajiv
    Wasty, Najam
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (08): : E216 - E218
  • [25] Adverse Events and Complications Associated With Intrathecal Drug Delivery Systems: Insights From the Manufacturer and User Facility Device Experience (MAUDE) Database
    Goel, Vasudha
    Yang, Yan
    Kanwar, Siddak
    Banik, Ratan K.
    Patwardhan, Amol M.
    Ibrahim, Mohab
    Sivanesan, Eellan
    Shankar, Hariharan
    NEUROMODULATION, 2021, 24 (07): : 1181 - 1189
  • [26] DEVICE-RELATED DEVIATION DURING PERCUTANEOUS NEPHROLITHOTOMY: REVIEW OF THE MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE (MAUDE) DATABASE
    Patel, Neel
    Schulman, Ariel
    Uppaluri, Nikil
    Phillips, John
    Choudhury, Muhammad
    Konno, Sensuke
    Eshghi, Majid
    JOURNAL OF UROLOGY, 2017, 197 (04): : E580 - E581
  • [27] QUANTIFYING THE UNDERREPORTING OF DEATH FOR CARDIOVASCULAR DEVICES IN THE FDA MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE (MAUDE) DATABASE
    Lalani, Christina
    Kunwar, Elysha M.
    Kinard-Tomes, Madris
    Dhruva, Sanket
    Redberg, Rita
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 3221 - 3221
  • [28] Adverse events related to laser fibers and laser machines during ureteroscopy and stone lithotripsy: Insights from an updated 10-year analysis of the US MAUDE database
    Juliebo-Jones, Patrick
    Aesoy, Mathias Sorstrand
    Beisland, Christian
    De Coninck, Vincent
    Keller, Etienne Xavier
    Tzelves, Lazaros
    Gjengsto, Peder
    Moen, Christian Arvei
    Somani, Bhaskar K.
    Ulvik, Oyvind
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2024, 96 (03)
  • [29] Adverse Events Associated With the Use of Guide Extension Catheter During Percutaneous Coronary Intervention: Reports From the Manufacturer and User Facility Device Experience (MAUDE) database
    Chen, Yuefeng
    Shah, Arhum A.
    Shlofmitz, Evan
    Khalid, Nauman
    Rogers, Toby
    Bernardo, Nelson L.
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S20 - S20
  • [30] Adverse Events Associated with the Use of Guide Extension Catheters during Percutaneous Coronary Intervention: Reports from the Manufacturer and User Facility Device Experience (MAUDE) database
    Chen, Yuefeng
    Shah, Arhum A.
    Shlofmitz, Evan
    Khalid, Nauman
    Musallam, Anees
    Khan, Jaffar M.
    Iantorno, Micaela
    Gajanana, Deepakraj
    Rogers, Toby
    Hashim, Hayder
    Bernardo, Nelson L.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (05) : 409 - 412