Improved microstrip ring resonator for dielectric response tests and moisture evaluation of oil-impregnated pressboard

被引:1
|
作者
Zhang, Daning [1 ]
Xu, Lulin [1 ]
Wu, Ming [1 ]
Jiang, Jiongting [2 ]
Shao, Xianjun [3 ]
Mu, Haibao [1 ]
Zhang, Guanjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Shaanxi, Peoples R China
[2] State Grid Zhejiang Power Co Ltd, Ningbo Power Supply Co, Ningbo 315016, Zhejiang, Peoples R China
[3] State Grid Zhejiang Elect Power Co Ltd, Elect Power Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 10期
关键词
TRANSFORMER PRESSBOARD; CONSTANT; INSULATION; WATER; PURE;
D O I
10.1063/5.0158883
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Moisture ingress is one of the major causes of aging in oil-paper insulated transformers; the measurement of the moisture content of the insulating material is thus necessary during transformer disassembly for maintenance. One critical engineering consideration is the need for rapid and nondestructive moisture content measurement of the oil-paper insulation to minimize the power-outage time. Herein, a rapid characterization method for the moisture content of oil-paper insulation based on the dielectric response obtained using a microstrip petal-like ring resonator (MPRR) is proposed. The geometric parameters of the resonator and dielectric response model were established based on simulations and theoretical analysis. The geometry of the resonant ring was optimized by modifying the originally circular ring structure of the microstrip ring resonator (MRR) into a petal-like ring structure; this increases the number of resonant peaks from five to seven in the frequency range of 0.5-6.0 GHz for the same electrode area. The effects of the coupling mode, coupling gap, and microstrip ring size on the resonance characteristics of the MPRR were simulated and analyzed. Compared with the MRR, the MPRR has the advantages of a reduced fundamental resonant frequency and a smaller resonant-ring area that improves radiation efficiency. The impact of moisture content on the dielectric response of the pressboard obtained using the MPRR was studied. A moisture-calculation equation based on the measured dielectric response for a selected type of pressboard was established by the Lasso regression. The results of verification experiments show that the error of the proposed method is sufficient for practical applications.
引用
收藏
页数:14
相关论文
共 39 条
  • [21] Nonlinear Dielectric Response Characteristics of Damp Oil-Impregnated Pressboard Insulation and Application of H-W Model in Time-Frequency Conversion
    Deng Y.
    Yang L.
    Yan F.
    Qin Z.
    Li W.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (21): : 4609 - 4619
  • [22] Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation
    Ekanayake, Chandima
    Gubanski, Stanislaw M.
    Graczkowski, Andrzej
    Walczak, Krzysztof
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1309 - 1317
  • [23] Dielectric response of oil-impregnated paper insulation:: Variation with humidity and ageing level
    Linhjell, D
    Gäfvert, U
    Lundgaard, LE
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 262 - 266
  • [24] Wide-Band Model for Dielectric Response of Oil-Impregnated Paper Insulation
    Yang, Feng
    Du, Lin
    Yang, Lijun
    Wang, Youyuan
    Ran, Liman
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 149 - 152
  • [25] Dielectric response of oil-impregnated cellulose from 0.1 mHz to 3 MHz
    Linhjell, D
    Hestad, OL
    Gäfvert, U
    Lundgaard, LE
    ICDL: 2005 IEEE INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS, 2005, : 277 - 280
  • [26] Dielectric Frequency Response of Oil-impregnated Paper: the Effect of Partial Discharges Compared to other Influences
    Niasar, M. Ghaffarian
    Taylor, N.
    Edin, H.
    Kiiza, R. Clemence
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1769 - 1777
  • [27] On the Impacts of Ageing and Moisture on Dielectric Response of Oil Impregnated Paper Insulation Systems
    Betie, A.
    Meghnefi, F.
    Fofana, I.
    Yeo, Z.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 219 - 222
  • [28] On-site application of dielectric response diagnosis on service aged oil-impregnated HV power cables
    Cichecki, Piotr
    Onderwater, L. P. A.
    Gulski, Edward
    Smit, J. J.
    Seitz, P. P.
    de Vries, F.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1136 - +
  • [29] A modified microstrip ring resonator sensor with lumped element modeling for soil moisture and dielectric predictions measurement
    Then, Yi Lung
    You, Kok Yeow
    Dimon, Mohamad Ngasri
    Lee, Chia Yew
    MEASUREMENT, 2016, 94 : 119 - 125
  • [30] Dielectric Response Properties and Moisture Assessment of Oil-Paper Insulation Based on Micro-Strip Ring Resonator
    Wu M.
    Zhang D.
    Shao X.
    Yang Z.
    Li Q.
    Zhang G.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (03): : 633 - 647