Improved microstrip ring resonator for dielectric response tests and moisture evaluation of oil-impregnated pressboard

被引:1
|
作者
Zhang, Daning [1 ]
Xu, Lulin [1 ]
Wu, Ming [1 ]
Jiang, Jiongting [2 ]
Shao, Xianjun [3 ]
Mu, Haibao [1 ]
Zhang, Guanjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Shaanxi, Peoples R China
[2] State Grid Zhejiang Power Co Ltd, Ningbo Power Supply Co, Ningbo 315016, Zhejiang, Peoples R China
[3] State Grid Zhejiang Elect Power Co Ltd, Elect Power Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 10期
关键词
TRANSFORMER PRESSBOARD; CONSTANT; INSULATION; WATER; PURE;
D O I
10.1063/5.0158883
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Moisture ingress is one of the major causes of aging in oil-paper insulated transformers; the measurement of the moisture content of the insulating material is thus necessary during transformer disassembly for maintenance. One critical engineering consideration is the need for rapid and nondestructive moisture content measurement of the oil-paper insulation to minimize the power-outage time. Herein, a rapid characterization method for the moisture content of oil-paper insulation based on the dielectric response obtained using a microstrip petal-like ring resonator (MPRR) is proposed. The geometric parameters of the resonator and dielectric response model were established based on simulations and theoretical analysis. The geometry of the resonant ring was optimized by modifying the originally circular ring structure of the microstrip ring resonator (MRR) into a petal-like ring structure; this increases the number of resonant peaks from five to seven in the frequency range of 0.5-6.0 GHz for the same electrode area. The effects of the coupling mode, coupling gap, and microstrip ring size on the resonance characteristics of the MPRR were simulated and analyzed. Compared with the MRR, the MPRR has the advantages of a reduced fundamental resonant frequency and a smaller resonant-ring area that improves radiation efficiency. The impact of moisture content on the dielectric response of the pressboard obtained using the MPRR was studied. A moisture-calculation equation based on the measured dielectric response for a selected type of pressboard was established by the Lasso regression. The results of verification experiments show that the error of the proposed method is sufficient for practical applications.
引用
收藏
页数:14
相关论文
共 39 条
  • [1] DIELECTROMETRY MEASUREMENTS OF MOISTURE DYNAMICS IN OIL-IMPREGNATED PRESSBOARD
    SHEIRETOV, Y
    ZAHN, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (03) : 329 - 351
  • [2] Estimation of Moisture Content in Oil-impregnated Pressboard through Analyzing Dielectric Response Current under Switching Impulse
    Pradhan, A. K.
    Tenbohlen, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (03) : 938 - 945
  • [3] Moisture and space charge in oil-impregnated pressboard under HVDC
    Liu, RS
    Jaksts, A
    Tornkvist, C
    Bergkvist, M
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 17 - 22
  • [4] Investigation of Moisture Influence on Dielectric Response of Ester Oil Impregnated Pressboard
    Bandara, Kapila
    Ekanayake, Chandima
    Saha, Tapan
    Ma, Hui
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [5] Understanding Moisture Diffusion Process in Oil-Impregnated Pressboard Insulation of Transformer
    Jadav, Raj B.
    Saha, Tapan K.
    Ekanayake, Chandima
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [6] Investigation on Dielectric Response Characteristics of Thermally Aged Insulating Pressboard in Vacuum and Oil-impregnated Ambient
    Wang, Shi-Qiang
    Zhang, Guan-Jun
    Wei, Jian-Lin
    Yang, Shuang-Suo
    Dong, Ming
    Huang, Xin-Bo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (06) : 1853 - 1862
  • [7] Dielectric response characteristics and moisture exposure evaluation of oil-paper insulation based on microstrip ring resonator
    Xu, Lulin
    Zhang, Daning
    Jiang, Jiongting
    Mu, Haibao
    Zhang, Guanjun
    MEASUREMENT, 2024, 234
  • [8] Improved method for measuring moisture content of mineral-oil-impregnated cellulose pressboard based on dielectric response
    M. Zhang
    J. Liu
    J. Lv
    Q. Chen
    P. Qi
    Y. Sun
    H. Jia
    X. Chen
    Cellulose, 2018, 25 : 5611 - 5622
  • [9] Improved method for measuring moisture content of mineral-oil-impregnated cellulose pressboard based on dielectric response
    Zhang, M.
    Liu, J.
    Lv, J.
    Chen, Q.
    Qi, P.
    Sun, Y.
    Jia, H.
    Chen, X.
    CELLULOSE, 2018, 25 (10) : 5611 - 5622
  • [10] Influence of Moisture and Ageing on Dielectric Response of Ester and Mineral Oil Impregnated Pressboard Insulation
    Bandara, Kapila
    Saha, Tapan K.
    Ekanayake, Chandima
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,