Can Non-Invasive Spectrophotometric Hemoglobin Replace Laboratory Hemoglobin Concentrations for Preoperative Anemia Screening? A Diagnostic Test Accuracy Study

被引:6
|
作者
Alwabari, Maryam [1 ]
Alhamad, Fatimah [2 ]
Alsahaf, Fatimah [2 ]
Al Amer, Fatima [2 ]
Alniniya, Fatma [1 ]
Alherz, Imran [1 ]
Omer, Nawal [3 ]
Bushehab, Abdulaziz [4 ]
Yassen, Khaled [5 ]
机构
[1] King Fahad Hosp, Minist Hlth, Anesthesia Dept, Al Hufuf 36441, Al Ahsa, Saudi Arabia
[2] King Faisal Univ, Coll Med, Al Hufuf 31983, Al Ahsa, Saudi Arabia
[3] Hereditary Blood Dis Ctr, Al Hufuf 36422, Al Hasa, Saudi Arabia
[4] Hereditary Blood Dis Ctr, Nursing Serv, Al Hufuf 36422, Al Ahsa, Saudi Arabia
[5] King Faisal Univ, Coll Med, Surg Dept, Anesthesia Unit, Al Hufuf 31983, Al Ahsa, Saudi Arabia
关键词
hemoglobin; anemia; monitoring; non-invasive; preoperative; NONCARDIAC SURGERY; OXIMETRY; OXYGEN; BIAS;
D O I
10.3390/jcm12175733
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Preoperative assessment of hemoglobin concentration in blood is important to diagnose anemia. The primary aim of this prospective diagnostic test accuracy study was to monitor noninvasive spectrophotometric hemoglobin (SpHb, g/dL) concentrations among adults prior to elective surgery and to investigate the correlation and agreement of SpHb with laboratory hemoglobin (Hb, g/dl). A secondary aim was to identify the anemia cut-off values for SpHb based on the World Health Organization (WHO) definitions for anemia. This study included 151 consecutive patients (age >= 18 year) presenting for preoperative evaluation prior to scheduled elective general or orthopedic surgery. Results identified the mean +/- SD of SpHb at 11.43 +/- 2.01 g/dL, which underestimated the mean laboratory Hb (12.64 +/- 2.29 g/dL, p < 0.001). A bias mean difference (SpHb-Hb) of -1.21 g/dL, with a SD of 1.76, was reported. This bias (SpHb-Hb) was inversely correlated with the mean Hb concentrations. A positive correlation existed between SpHb and Hb, with a good degree of reliability and a significant Intra Class Correlation (ICC). SpHb diagnosed anemia in 32.3% and 60.3% of males and females, respectively. The SpHb cut-off values to identify anemia were 11.3 and 10.2 g/dL for males and females, respectively, with a sensitivity of 83.3% for males and only 62.9% for females. The specificity for males and females were 81% and 91.3%, respectively. SpHb sensitivity allows for anemia diagnosis among males, but not females. However, the specificity allows SpHb to rule out anemia for both.
引用
收藏
页数:13
相关论文
共 33 条
  • [21] Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients
    Werner Baulig
    Burkhardt Seifert
    Donat R. Spahn
    Oliver M. Theusinger
    Journal of Clinical Monitoring and Computing, 2017, 31 : 177 - 185
  • [22] Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients
    Baulig, Werner
    Seifert, Burkhardt
    Spahn, Donat R.
    Theusinger, Oliver M.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (01) : 177 - 185
  • [23] NiADA (Non-invasive Anemia Detection App), a Smartphone-Based Application With Artificial Intelligence to Measure Blood Hemoglobin in Real-Time: A Clinical Validation
    Das, Semanti
    Ahamed, Farhad
    Das, Aditi
    Das, Debjeet
    Nandi, Jhuma
    Banerjee, Krishanu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [24] Towards a Multi-model Comparative Study for Non-invasive Hemoglobin Level Prediction from Fingertip Video
    Sabith, Nafi Us Sabbir
    Sridevi, Parama
    Arefin, Kazi Zawad
    Rabbani, Masud
    Ahamed, Sheikh Iqbal
    2024 IEEE INTERNATIONAL CONFERENCE ON DIGITAL HEALTH, ICDH 2024, 2024, : 172 - 180
  • [25] Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children—a method comparison study
    Aditya Bhat
    Amit Upadhyay
    Vijay Jaiswal
    Deepak Chawla
    Dharamveer Singh
    Mithilesh Kumar
    C. P. Yadav
    European Journal of Pediatrics, 2016, 175 : 171 - 179
  • [26] Usefulness of non-invasive spectrophotometric haemoglobin estimation for detecting low haemoglobin levels when compared with a standard laboratory assay for preoperative assessment
    Khalafallah, A. A.
    Chilvers, C. R.
    Thomas, M.
    Chilvers, C. M.
    Sexton, M.
    Vialle, M.
    Robertson, I. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (04) : 669 - 676
  • [27] The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study
    Ferrando, Carlos
    Romero, Carolina
    Tusman, Gerardo
    Suarez-Sipmann, Fernando
    Canet, Jaume
    Dosda, Rosa
    Valls, Paola
    Villena, Abigail
    Serralta, Ferran
    Jurado, Ana
    Carrizo, Juan
    Navarro, Jose
    Parrilla, Cristina
    Romero, Jose E.
    Pozo, Natividad
    Soro, Marina
    Villar, Jesus
    Belda, Francisco Javier
    BMJ OPEN, 2017, 7 (05):
  • [28] Determining the validity of non-invasive spot-check hemoglobin co-oximetry testing to detect anemia in postpartum women at a tertiary care centre, a prospective cohort study
    Mills, Kienna
    Vermeer, Julie M.
    Berry, Warren E.
    Karreman, Erwin
    Lett, Christine D.
    BMC PREGNANCY AND CHILDBIRTH, 2023, 23 (01)
  • [29] Determining the validity of non-invasive spot-check hemoglobin co-oximetry testing to detect anemia in postpartum women at a tertiary care centre, a prospective cohort study
    Kienna Mills
    Julie M. Vermeer
    Warren E. Berry
    Erwin Karreman
    Christine D. Lett
    BMC Pregnancy and Childbirth, 23
  • [30] Diagnostic Accuracy of Controlled Attenuation Parameter Measured by Transient Elastography for the Non-invasive Assessment of Liver Steatosis: a Prospective Study
    Lupsor-Platon, Monica
    Feier, Diana
    Stefanescu, Horia
    Tamas, Attila
    Botan, Emil
    Sparchez, Zeno
    Maniu, Anca
    Badea, Radu
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2015, 24 (01) : 35 - 42