Can Non-Invasive Spectrophotometric Hemoglobin Replace Laboratory Hemoglobin Concentrations for Preoperative Anemia Screening? A Diagnostic Test Accuracy Study

被引:6
|
作者
Alwabari, Maryam [1 ]
Alhamad, Fatimah [2 ]
Alsahaf, Fatimah [2 ]
Al Amer, Fatima [2 ]
Alniniya, Fatma [1 ]
Alherz, Imran [1 ]
Omer, Nawal [3 ]
Bushehab, Abdulaziz [4 ]
Yassen, Khaled [5 ]
机构
[1] King Fahad Hosp, Minist Hlth, Anesthesia Dept, Al Hufuf 36441, Al Ahsa, Saudi Arabia
[2] King Faisal Univ, Coll Med, Al Hufuf 31983, Al Ahsa, Saudi Arabia
[3] Hereditary Blood Dis Ctr, Al Hufuf 36422, Al Hasa, Saudi Arabia
[4] Hereditary Blood Dis Ctr, Nursing Serv, Al Hufuf 36422, Al Ahsa, Saudi Arabia
[5] King Faisal Univ, Coll Med, Surg Dept, Anesthesia Unit, Al Hufuf 31983, Al Ahsa, Saudi Arabia
关键词
hemoglobin; anemia; monitoring; non-invasive; preoperative; NONCARDIAC SURGERY; OXIMETRY; OXYGEN; BIAS;
D O I
10.3390/jcm12175733
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Preoperative assessment of hemoglobin concentration in blood is important to diagnose anemia. The primary aim of this prospective diagnostic test accuracy study was to monitor noninvasive spectrophotometric hemoglobin (SpHb, g/dL) concentrations among adults prior to elective surgery and to investigate the correlation and agreement of SpHb with laboratory hemoglobin (Hb, g/dl). A secondary aim was to identify the anemia cut-off values for SpHb based on the World Health Organization (WHO) definitions for anemia. This study included 151 consecutive patients (age >= 18 year) presenting for preoperative evaluation prior to scheduled elective general or orthopedic surgery. Results identified the mean +/- SD of SpHb at 11.43 +/- 2.01 g/dL, which underestimated the mean laboratory Hb (12.64 +/- 2.29 g/dL, p < 0.001). A bias mean difference (SpHb-Hb) of -1.21 g/dL, with a SD of 1.76, was reported. This bias (SpHb-Hb) was inversely correlated with the mean Hb concentrations. A positive correlation existed between SpHb and Hb, with a good degree of reliability and a significant Intra Class Correlation (ICC). SpHb diagnosed anemia in 32.3% and 60.3% of males and females, respectively. The SpHb cut-off values to identify anemia were 11.3 and 10.2 g/dL for males and females, respectively, with a sensitivity of 83.3% for males and only 62.9% for females. The specificity for males and females were 81% and 91.3%, respectively. SpHb sensitivity allows for anemia diagnosis among males, but not females. However, the specificity allows SpHb to rule out anemia for both.
引用
收藏
页数:13
相关论文
共 33 条
  • [1] Non-invasive hemoglobin estimation for preoperative anemia screening
    Hornedo-Gonzalez, Kevin D.
    Jacob, Adam K.
    Burt, Jennifer M.
    Higgins, Andrew A.
    Engel, Elizabeth M.
    Hanson, Andrew C.
    Belch, Lisa
    Kor, Daryl J.
    Warner, Matthew A.
    TRANSFUSION, 2023, 63 (02) : 315 - 322
  • [2] Non-invasive Hemoglobin Measurement for Anemia Diagnosis
    Rochmanto, Raditya Artha
    Zakaria, Hasballah
    Alviana, Ratih Devi
    Shahib, Nurhalim
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), 2017, : 125 - 129
  • [3] Non-invasive Hemoglobin Screening for Detection of Postpartum Anemia
    Das Mahapatra, Partha Pratim
    Mohakud, Nirmal Kumar
    Roy, Chaitali
    Rajagopal, Harshavardhan
    Sharma, Sandeep
    WOMENS HEALTH REPORTS, 2024, 5 (01): : 565 - 571
  • [4] Use of non-invasive total hemoglobin measurement as a screening tool for anemia in children
    Amano, Izuki
    Murakami, Ayako
    PEDIATRICS INTERNATIONAL, 2013, 55 (06) : 803 - 805
  • [5] Non-invasive hemoglobin screening device: a promising digital method for reducing anemia prevalence through routine screening and timely intervention
    Das Mahapatra, Partha Pratim
    Roy, Chaitali
    Agarwal, Komal
    Sharma, Sonal Deep
    Chowdhury, Sudip Roy
    Sharma, Sandeep
    Rajagopal, Harshavardhan
    Meher, Dayanidhi
    HEMATOLOGY, 2024, 29 (01)
  • [6] Diagnostic accuracy of a non-invasive spot-check hemoglobin meter, Masimo Rad-67® pulse CO-Oximeter®, in detection of anemia in antenatal care settings in Kenya
    Koech, Angela
    Mwaniki, Isaac
    Mutunga, Joseph
    Mukhanya, Moses
    Mwadime, Emily
    Ochieng, Marvine
    Mwashigadi, Grace
    Mistry, Hiten D.
    Craik, Rachel
    von Dadelszen, Peter
    Temmerman, Marleen
    Luchters, Stanley
    Omuse, Geoffrey
    FRONTIERS IN GLOBAL WOMENS HEALTH, 2024, 5
  • [7] Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses
    Adel, Abdelmoneim
    Awada, Wael
    Abdelhamid, Bassant
    Omar, Heba
    Abd El Dayem, Omnia
    Hasanin, Ahmed
    Rady, Ashraf
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (06) : 1025 - 1031
  • [8] Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses
    Abdelmoneim Adel
    Wael Awada
    Bassant Abdelhamid
    Heba Omar
    Omnia Abd El Dayem
    Ahmed Hasanin
    Ashraf Rady
    Journal of Clinical Monitoring and Computing, 2018, 32 : 1025 - 1031
  • [9] Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study
    Chang, Feng-Cheng
    Lin, Jr-Rung
    Liu, Fu-Chao
    BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [10] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Hahn, Robert G.
    Wuethrich, Patrick Y.
    Zdolsek, Joachim H.
    BMC ANESTHESIOLOGY, 2021, 21 (01)