Grid Harmonics Suppression for Three Phase Dual-Frequency Grid-Connected Inverter Based on Feedforward Compensation

被引:0
|
作者
Chen, Zhigang [1 ,2 ]
Ma, Dongkai [2 ]
Yang, Liyong [2 ]
Liu, Shuo [2 ]
Tong, Chaonan [1 ]
Zhao, Yifan [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[2] North China Univ Technol, Coll Elect & Control Engn, Beijing 100144, Peoples R China
来源
SYMMETRY-BASEL | 2023年 / 15卷 / 08期
关键词
three-phase grid-connected inverter; current ripple; power quality; LCL-FILTER; CONTROL STRATEGY; CONTROL SCHEME; DESIGN; TOPOLOGY;
D O I
10.3390/sym15081517
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Using a low pulse ratio, the electromagnetic interference and switching loss of an inverter can be effectively reduced, particularly in high-power applications. However, due to variations in grid impedance, it is a challenging task to achieve stable operation of an LCL-type grid-connected inverter (GCI) using the active damping method with low pulse ratio. Thus, a novel three-phase dual-frequency GCI is presented to ensure the symmetry of the output power and the stable operation of the system address stability issues. The proposed inverter topology in this article is composed of two inverters in parallel, which are, respectively, a power inverter unit (PIU) and an auxiliary harmonic elimination unit (AHEU). To reduce the switching loss and improve the inverter efficiency, the switching frequency of the PIU is relatively low, injecting current into the grid. Moreover, the feedforward compensation method is used in AHEU. AHEU operates at high switching frequency to generate a current component that is symmetrical with the ripple com-ponent, improving the power quality, without extracting the current harmonic as the current reference. The operating principle of feedforward compensation is explained, and a proper parameter design procedure is presented in this paper. Since L filters are used for the proposed inverter, the system can operate stably where the ratio of switching frequency to fundamental frequency is low. A 10 kW laboratory prototype was built. The experimental results showed that the grid current ripple could be effectively eliminated and the THD of the grid current was 3.01%. The proposed inverter has good stability in a weak grid, and the efficiency of the proposed inverter is 95.98% at rated current, which is 0.81% higher than the traditional GCI, effectively increasing the efficiency of the system.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Multi-Resonance Control and Phase Margin Compensation Method of Grid-Connected Inverter Based on Voltage and Current Feedforward
    Hou, Jingwen
    Wang, Chengsheng
    Duan, Wei
    Lan, Zhiming
    Jiang, Jun
    Yang, Qiongtao
    2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
  • [32] Analysis and design of L plus LCL-filtered dual-frequency single-phase grid-connected inverter
    Yang, Liyong
    He, Xiaojuan
    Chang, Aoyu
    Liu, Shuo
    IET POWER ELECTRONICS, 2020, 13 (07) : 1416 - 1425
  • [33] Capacitor voltage feedforward control strategy of grid-connected inverter in weak grid
    Yang M.
    Bao J.
    Sun Y.
    Wei Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 94 - 102
  • [34] Active damping of LCL-Filtered Grid-Connected inverter based on parallel feedforward compensation strategy
    Khan, Danish
    Zhu, Keping
    Hu, Pengfei
    Waseem, Muhammad
    Ahmed, Emad M.
    Lin, Zhenzhi
    AIN SHAMS ENGINEERING JOURNAL, 2023, 14 (03)
  • [35] Research on MRSMC for Three-phase Grid-Connected Inverter
    Hu, Qinjun
    Zhang, Zhilin
    Liu, Hua
    Zhang, Liang
    2019 IEEE INTERNATIONAL SYMPOSIUM ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2019), 2019, : 304 - 307
  • [36] Selective compensation of voltage harmonics in grid-connected microgrids
    Savaghebi, Mehdi
    Vasquez, Juan C.
    Jalilian, Alireza
    Guerrero, Josep M.
    Lee, Tzung-Lin
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2013, 91 : 211 - 228
  • [37] AN IMPROVED CONTROL METHOD OF PHASE COMPENSATION FOR PHOTOVOLTAIC GRID-CONNECTED INVERTER
    Li, Shengqing
    Zhang, Yuwen
    Ming, Yao
    Wu, Wenfeng
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2020, 35 (05): : 401 - 407
  • [38] Research on suppression strategy of low frequency subharmonics of grid-connected inverter based on PIR
    Li Y.
    Huang X.
    Xia Z.
    Li P.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (12): : 32 - 40
  • [39] DC Offset Compensation Algorithm in the Grid Voltage of Single-phase Grid-connected Inverter
    Kim, Tae-Seong
    Hwang, Seon-Hwan
    Kim, Jin-soo
    Park, Jong-Won
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 2457 - 2460
  • [40] A resonance suppression strategy of LCL-type grid-connected inverter based on compound voltage feedforward
    Yan, Haichao
    Zhao, Mi
    Lu, Min
    Cen, HongLei