An integrated and fast imaging quality assurance phantom for a 0.35 T magnetic resonance imaging linear accelerator

被引:1
作者
Sohn, James J. [1 ]
Lim, Sara [1 ]
Das, Indra J. [1 ]
Yadav, Poonam [1 ]
机构
[1] Northwestern Univ, Northwestern Mem Hosp, Dept Radiat Oncol, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
Magnetic resonance imaging linear accelerator; Imaging; Magnetic resonance imaging guided radiation; therapy; MRIdian; QA; Magphan; ACR alternatives; MR-LINAC; RADIATION; IMPLEMENTATION;
D O I
10.1016/j.phro.2023.100462
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Periodic imaging quality assurance (QA) of magnetic resonance imaging linear accelerator (MRL) is critical. The feasibility of a new MRL imaging phantom used for QA in the low field was evaluated with auto-mated image analysis of various parameters for accuracy and reproducibility. Methods and materials: The new MRL imaging phantom was scanned across every 30 degrees of the gantry, having the on/off state of the linac in a low-field MRL system using three magnetic resonance imaging sequences: true fast imaging with steady-state precession (TrueFISP), T1 weighted (T1W), and T2 weighted (T2W). The DICOM files were used to calculate the imaging parameters: geometric distortion, uniformity, resolution, signal-to-noise ratio (SNR), and laser alignment. The point spread function (PSF) and edge spread function (ESF) were also calculated for resolution analysis. Results: The phantom data showed a small standard deviation -and high consistency for each imaging parameter. The highest variability in data was observed with the true fast imaging sequence at the calibration angle, which was expected because of low resolution and short scan time (25 sec). The mean magnitude of the largest distortion measured within 200 mm diameter with TrueFISP was 0.31 & PLUSMN; 0.05 mm. The PSF, ESF, signal uni-formity, and SNR measurements remained consistent. Laser alignment traditional offsets and angular deviation remained consistent. Conclusions: The new MRL imaging phantom is reliable, reproducible, time effective, and easy to use for a 0.35 T MRL system. The results promise a more streamlined, time-saving, and error-free QA process for low-field MRL adapted in our clinical setting.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Comparison of Pulse Sequences of Magnetic Resonance Imaging for Optimization of Timing and Image Quality [J].
Amin N. ;
Yousaf M. ;
Javid M.A. ;
Farooq A. .
Iranian Journal of Medical Physics, 2020, 17 (06) :350-358
[42]   Serial 3 T magnetic resonance imaging during cabergoline treatment of macroprolactinomas [J].
Kurosaki, Masamichi ;
Kambe, Atsushi ;
Watanabe, Takashi ;
Fujii, Shinya ;
Ogawa, Toshihide .
NEUROLOGICAL RESEARCH, 2015, 37 (04) :341-346
[43]   Upper Urinary Tract Stereotactic Body Radiotherapy Using a 1.5 Tesla Magnetic Resonance Imaging-Guided Linear Accelerator: Workflow and Physics Considerations [J].
Zhao, Yao ;
Cozma, Adrian ;
Ding, Yao ;
Perles, Luis Augusto ;
Reiazi, Reza ;
Chen, Xinru ;
Kang, Anthony ;
Prajapati, Surendra ;
Yu, Henry ;
Subashi, Ergys David ;
Brock, Kristy ;
Wang, Jihong ;
Beddar, Sam ;
Lee, Belinda ;
Mohammedsaid, Mustefa ;
Cooper, Sian ;
Westley, Rosalyne ;
Tree, Alison ;
Mohamad, Osama ;
Hassanzadeh, Comron ;
Mok, Henry ;
Choi, Seungtaek ;
Tang, Chad ;
Yang, Jinzhong .
CANCERS, 2024, 16 (23)
[44]   A METHOD OF PRODUCING HIGH-QUALITY LINEAR FIELD GRADIENT FOR MAGNETIC-RESONANCE-IMAGING USING STRAIGHT CURRENT LINES [J].
FURUSAWA, M ;
IKEYA, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1991, 30 (9B) :L1682-L1685
[45]   Longitudinal assessment of quality assurance measurements in a 1.5T MR-linac: Part I-Linear accelerator [J].
Subashi, Ergys ;
Lim, Seng Boh ;
Gonzalez, Xesus ;
Tyagi, Neelam .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10) :190-201
[46]   Magnetic Nanoparticles Supporting Bio-responsive T1/T2 Magnetic Resonance Imaging [J].
Ellis, Connor M. ;
Pellico, Juan ;
Davis, Jason J. .
MATERIALS, 2019, 12 (24)
[47]   Comparison of Prospectively Generated Glioma Treatment Plans Clinically Delivered on Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) Versus Conventional Linac: Predicted and Measured Skin Dose [J].
Wang, Michael H. ;
Kim, Anthony ;
Ruschin, Mark ;
Tan, Hendrick ;
Soliman, Hany ;
Myrehaug, Sten ;
Detsky, Jay ;
Husain, Zain ;
Atenafu, Eshetu G. ;
Keller, Brian ;
Sahgal, Arjun ;
Tseng, Chia-Lin .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
[48]   A Fast 3-Dimensional Magnetic Resonance Imaging Reconstruction for Surgical Planning of Uterine Myomectomy [J].
Lee, Sa Ra ;
Kim, Young Jae ;
Kim, Kwang Gi .
JOURNAL OF KOREAN MEDICAL SCIENCE, 2018, 33 (02)
[49]   Availability and quality of computed tomography and magnetic resonance imaging equipment in US emergency departments [J].
Ginde, Adit A. ;
Foianini, Anthony ;
Renner, Daniel M. ;
Valley, Morgan ;
Camargo, Carlos A., Jr. .
ACADEMIC EMERGENCY MEDICINE, 2008, 15 (08) :780-783
[50]   An Adaptable Nanoplatform for Integrating Anatomic and Functional Magnetic Resonance Imaging under a 3.0 T Magnetic Field [J].
Shen, Aijun ;
Meng, Xianfu ;
Gao, Xiaolong ;
Xu, Xiaowen ;
Shoo, Chulun ;
Tang, Zhongmin ;
Liu, Yanyan ;
Bu, Wenbo ;
Wang, Peijun .
ADVANCED FUNCTIONAL MATERIALS, 2019, 29 (02)