Short-wave infrared fluorescence imaging of near-infrared dyes with robust end-tail emission using a small-animal imaging device

被引:2
|
作者
Arena, Francesca [1 ]
La Cava, Francesca [1 ]
Faletto, Daniele [1 ]
Roberto, Miriam [2 ]
Crivellin, Federico [1 ]
Stummo, Francesco [1 ]
Adamo, Alessia [1 ]
Boccalon, Mariangela [1 ]
Napolitano, Roberta [1 ]
Blasi, Francesco [1 ]
Koch, Maximilian [3 ]
Taruttis, Adrian [3 ]
Reitano, Erika [3 ]
机构
[1] Bracco Imaging SpA, Bracco Res Ctr, I-10010 Turin, Italy
[2] Univ Torino, Mol Imaging Ctr, Dept Mol Biotechnol & Hlth Sci, I-10126 Turin, Italy
[3] SurgVision GmbH, D-81379 Munich, Germany
来源
PNAS NEXUS | 2023年 / 2卷 / 08期
关键词
short-wave infrared imaging; hindlimb vasculature; deep-tissue imaging; principal component analysis; biomedical imaging; INDOCYANINE GREEN; II FLUORESCENCE;
D O I
10.1093/pnasnexus/pgad250
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Commercially available near-infrared (NIR) dyes, including indocyanine green (ICG), display an end-tail of the fluorescence emission spectrum detectable in the short-wave infrared (SWIR) window. Imaging methods based on the second NIR spectral region (1,000-1,700 nm) are gaining interest within the biomedical imaging community due to minimal autofluorescence and scattering, allowing higher spatial resolution and depth sensitivity. Using a SWIR fluorescence imaging device, the properties of ICG vs. heptamethine cyanine dyes with emission >800 nm were evaluated using tissue-simulating phantoms and animal experiments. In this study, we tested the hypothesis that an increased rigidity of the heptamethine chain may increase the SWIR imaging performance due to the bathochromic shift of the emission spectrum. Fluorescence SWIR imaging of capillary plastic tubes filled with dyes was followed by experiments on healthy animals in which a time series of fluorescence hindlimb images were analyzed. Our findings suggest that higher spatial resolution can be achieved even at greater depths (>5 mm) or longer wavelengths (>1,100 nm), in both tissue phantoms and animals, opening the possibility to translate the SWIR prototype toward clinical application.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Using Short-wave Infrared Imaging for Fruit Quality Evaluation
    Zhang, Dong
    Lee, Dah-Jye
    Desai, Alok
    INTELLIGENT ROBOTS AND COMPUTER VISION XXXI: ALGORITHMS AND TECHNIQUES, 2014, 9025
  • [2] Date quality evaluation using short-wave infrared imaging
    Zhang, Dong
    Lee, Dah-Jye
    Tippetts, Beau J.
    Lillywhite, Kirt D.
    JOURNAL OF FOOD ENGINEERING, 2014, 141 : 74 - 84
  • [3] Excision of a gastrointestinal stromal tumour in a dog using short-wave infrared fluorescence imaging and indocyanine green
    Choi, Jinyoung
    Lee, Sungin
    VETERINARY MEDICINE AND SCIENCE, 2024, 10 (04)
  • [4] Cyanine dyes as contrast agents for near-infrared imaging in vivo: acute tolerance, pharmacokinetics, and fluorescence imaging
    Ebert, Bernd
    Riefke, Bjoern
    Sukowski, Uwe
    Kai Licha
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [5] Intraoperative pulmonary neoplasm identification using near-infrared fluorescence imaging
    Kim, Hyun Koo
    Quan, Yu Hua
    Choi, Byeong Hyeon
    Park, Ji-Ho
    Han, Kook Nam
    Choi, Yeonho
    Kim, Beop-Min
    Choi, Young Ho
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (05) : 1497 - 1502
  • [6] Currently available and experimental dyes for intraoperative near-infrared fluorescence imaging of the ureters: a systematic review
    Slooter, M. D.
    Janssen, A.
    Bemelman, W. A.
    Tanis, P. J.
    Hompes, R.
    TECHNIQUES IN COLOPROCTOLOGY, 2019, 23 (04) : 305 - 313
  • [7] Near-Infrared Fluorescence Imaging of Liver Metastases in Rats using Indocyanine Green
    van der Vorst, Joost R.
    Hutteman, Merlijn
    Mieog, J. Sven D.
    de Rooij, Karien E.
    Kaijzel, Eric L.
    Lowik, Clemens W. G. M.
    Putter, Hein
    Kuppen, Peter J. K.
    Frangioni, John V.
    van de Velde, Cornelis J. H.
    Vahrmeijer, Alexander L.
    JOURNAL OF SURGICAL RESEARCH, 2012, 174 (02) : 266 - 271
  • [8] Rational Design of a Small Molecular Near-Infrared Fluorophore for Improved In Vivo Fluorescence Imaging
    Jo, Gayoung
    Park, Yoonbin
    Park, Min Ho
    Hyun, Hoon
    MATERIALS, 2023, 16 (22)
  • [9] Azaphosphinate Dyes: A Low Molecular Weight Near-Infrared Scaffold for Development of Photoacoustic or Fluorescence Imaging Probes
    Yin, Ruwen
    Brondsted, Frederik
    Li, Lin
    Mcafee, Julia L.
    Fang, Yuan
    Sykes, Joshua S.
    He, Yuchen
    Grant, Steven
    He, Jiang
    Stains, Cliff I.
    CHEMISTRY-A EUROPEAN JOURNAL, 2024, 30 (16)
  • [10] Impact of Substituents in Tumor Uptake and Fluorescence Imaging Ability of Near-Infrared Cyanine-like Dyes
    Patel, Nayan J.
    Manivannan, Ethirajan
    Joshi, Penny
    Ohulchanskyy, Tymish J.
    Nani, Roger R.
    Schnermann, Martin J.
    Pandey, Ravindra K.
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2015, 91 (05) : 1219 - 1230