Optic Nerve Diameter on Non-Contrast Computed Tomography and Intracranial Hypertension in Patients With Acute Brain Injury: A Validation Study

被引:3
作者
Kahan, Joshua [1 ,2 ,5 ]
Ong, Hanley [3 ]
Elnaas, Hailan [1 ,2 ]
Ch'ang, Judy H. H. [1 ,2 ]
Murthy, Santosh B. B. [1 ,2 ]
Merkler, Alexander E. E. [1 ,2 ]
Sabuncu, Mert R. R. [3 ,4 ]
Gupta, Ajay [3 ]
Kamel, Hooman [1 ,2 ]
机构
[1] Weill Cornell Med, Feil Family Brain & Mind Res Inst, Clin & Translat Neurosci Unit, New York, NY USA
[2] Weill Cornell Med, Dept Neurol, New York, NY USA
[3] Weill Cornell Med, Dept Radiol, New York, NY USA
[4] Cornell Univ, Cornell Tech, Sch Elect & Comp Engn, New York, NY USA
[5] 420 East 70th St,LH 413, New York, NY 10021 USA
关键词
computed tomography; intracranial pressure; optic nerve sheath diameter; subarachnoid hemorrhage; traumatic brain injury; CEREBROSPINAL-FLUID PRESSURE; SHEATH DIAMETER;
D O I
10.1089/neu.2023.0051
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Intracranial hypertension is a feared complication of acute brain injury that can cause ischemic stroke, herniation, and death. Identifying those at risk is difficult, and the physical examination is often confounded. Given the widespread availability and use of computed tomography (CT) in patients with acute brain injury, prior work has attempted to use optic nerve diameter measurements to identify those at risk of intracranial hypertension. We aimed to validate the use of optic nerve diameter measurements on CT as a screening tool for intracranial hypertension in a large cohort of brain-injured patients. We performed a retrospective observational cohort study in a single tertiary referral Neuroscience Intensive Care Unit. We identified patients with documented intracranial pressure (ICP) measures as part of their routine clinical care who had non-contrast CT head scans collected within 24 h, and then measured the optic nerve diameters and explored the relationship and test characteristics of these measures to identify those at risk of intracranial hypertension. In a cohort of 314 patients, optic nerve diameter on CT was linearly but weakly associated with ICP. When used to identify those with intracranial hypertension (> 20 mm Hg), the area under the receiver operator curve (AUROC) was 0.68. Using a previously proposed threshold of 0.6 cm, the sensitivity was 81%, specificity 43%, positive likelihood ratio 1.4, and negative likelihood ratio 0.45. CT-derived optic nerve diameter using a threshold of 0.6 cm is sensitive but not specific for intracranial hypertension, and the overall correlation is weak.
引用
收藏
页码:2282 / 2288
页数:7
相关论文
共 27 条
  • [1] Guidelines for the Management of Severe Traumatic Brain Injury, Fourth Edition
    Carney, Nancy
    Totten, Annette M.
    O'Reilly, Cindy
    Ullman, Jamie S.
    Hawryluk, Gregory W. J.
    Bell, Michael J.
    Bratton, Susan L.
    Chesnut, Randall
    Harris, Odette A.
    Kissoon, Niranjan
    Rubiano, Andres M.
    Shutter, Lori
    Tasker, Robert C.
    Vavilala, Monica S.
    Wilberger, Jack
    Wright, David W.
    Ghajar, Jamshid
    [J]. NEUROSURGERY, 2017, 80 (01) : 6 - 15
  • [2] THE ROLE OF SECONDARY BRAIN INJURY IN DETERMINING OUTCOME FROM SEVERE HEAD-INJURY
    CHESNUT, RM
    MARSHALL, LF
    KLAUBER, MR
    BLUNT, BA
    BALDWIN, N
    EISENBERG, HM
    JANE, JA
    MARMAROU, A
    FOULKES, MA
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (02) : 216 - 222
  • [3] Cicchetti DV., 1994, PSYCHOL ASSESSMENTS, V6, P284, DOI [10.1037/1040-3590.6.4.284doi.org/, 10.1037/1040-3590.6.4.284, DOI 10.1037/1040-3590.6.4.284]
  • [4] Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis
    Fernando, Shannon M.
    Tran, Alexandre
    Cheng, Wei
    Rochwerg, Bram
    Taljaard, Monica
    Kyeremanteng, Kwadwo
    English, Shane W.
    Sekhon, Mypinder S.
    Griesdale, Donald E. G.
    Dowlatshahi, Dar
    McCredie, Victoria A.
    Wijdicks, Eelco F. M.
    Almenawer, Saleh A.
    Inaba, Kenji
    Rajajee, Venkatakrishna
    Perry, Jeffrey J.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2019, 366
  • [5] Geeraerts T, 2008, CRIT CARE, V12, DOI [10.1186/cc6893, 10.1186/cc7006]
  • [6] Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests
    Hansen, HC
    Helmke, K
    [J]. JOURNAL OF NEUROSURGERY, 1997, 87 (01) : 34 - 40
  • [7] Hayreh SS., 1984, OPHTHALMOLOGICA, V189, p54C63
  • [8] Intracranial Pressure and Cerebral Perfusion Pressure Monitoring in Non-TBI Patients: Special Considerations
    Helbok, Raimund
    Olson, DaiWai M.
    Le Roux, Peter D.
    Vespa, Paul
    [J]. NEUROCRITICAL CARE, 2014, 21 : 85 - 94
  • [9] Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension .1. Experimental study
    Helmke, K
    Hansen, HC
    [J]. PEDIATRIC RADIOLOGY, 1996, 26 (10) : 701 - 705
  • [10] Ventriculostomy infections: The effect of monitoring, duration and catheter exchange in 584 patients
    Holloway, KL
    Barnes, T
    Choi, S
    Bullock, B
    Marshall, LF
    Eisenberg, HM
    Jane, JA
    Ward, JD
    Young, HF
    Marmarou, A
    [J]. JOURNAL OF NEUROSURGERY, 1996, 85 (03) : 419 - 424