Diagnosis of inter-turn short circuit in excitation winding of pumped storage unit based on frequency-resolved circulation spectrum

被引:6
作者
Qi, Peng [1 ]
Li, Yonggang [1 ]
Ma, Minghan [1 ]
Wu, Yucai [1 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Yonghua North St 619, Baoding, Peoples R China
基金
中国国家自然科学基金;
关键词
excitation winding; frequency-resolved circulation spectrum; inter-turn short-circuit; pumped storage unit; SYNCHRONOUS GENERATOR; FAULTS; TRANSIENT; MOTORS; IMPACT;
D O I
10.1049/elp2.12242
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The online monitoring of inter-turn short-circuit (ITSC) faults in excitation windings of pumped storage units is easily affected by static air-gap eccentricity (SAGE) and armature response, and the early fault characteristics cannot be easily identified effectively. To address these problems, this study proposes a frequency-resolved circulation spectrum (FRCS) fault diagnosis method for ITSC faults in excitation windings. Firstly, the equation for the same phase multi-branch circulation under SAGE compound ITSC conditions is derived based on the structural characteristics of pumped storage units and electromagnetic induction relations, and obtains the characteristic harmonics of the loop current caused by ITSC faults. Secondly, this study introduces the implementation method of FRCS, considering a pumped storage unit with a generation capacity of 334 MVA as the research object. This study develops a two-dimensional finite element simulation model, calculates the magnitude of the in-phase branch circulation at different fault levels, extracts the corresponding time and frequency domain spectrum and FRCS, and verifies the effectiveness of the proposed method based on comparative experiments. Finally, based on the MJF-30-6 Synchronous Generator Experimental Platform in the Power System Dynamic Simulation Laboratory, ITSC operation at different fault levels is simulated, and the corresponding in-phase branch current data are collected for FRCS analysis. The experimental results demonstrate that the method can effectively eliminate SAGE and armature reaction interference, identify early weak ITSC faults and visualise the severity of faults in the form of pixel dots.
引用
收藏
页码:14 / 35
页数:22
相关论文
共 27 条
[1]   Electrical Monitoring of Damper Bar Condition in Salient-Pole Synchronous Motors Without Motor Disassembly [J].
Antonino-Daviu, Jose ;
Fuster-Roig, Vicente ;
Park, Sanguk ;
Park, Yonghyun ;
Choi, Hanchun ;
Park, Jongsan ;
Lee, Sang Bin .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) :1423-1431
[2]   Noninvasive Detection of Winding Short-Circuit Faults in Salient Pole Synchronous Machine With Squirrel-Cage Damper [J].
Cuevas, Mauricio ;
Romary, Raphael ;
Lecointe, Jean-Philippe ;
Morganti, Fabrice ;
Jacq, Thierry .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) :5988-5997
[3]   Impact of Real Air-Gap Nonuniformity on the Electromagnetic Forces of a Large Hydro-Generator [J].
Dirani, Hind C. ;
Merkhouf, Arezki ;
Giroux, Anne-Marie ;
Kedjar, Bachir ;
Al-Haddad, Kamal .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (11) :8464-8475
[4]   Rotor Interturn Short Circuit Impact on Large Hydrogenerator Magnetic Quantities [J].
Dirani, Hind Chit ;
Merkhouf, Arezki ;
Kedjar, Bachir ;
Giroux, Anne-Marie ;
Al-Haddad, Kamal .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (04) :3702-3711
[5]   Advanced Fault Detection of Synchronous Generators Using Stray Magnetic Field [J].
Ehya, Hossein ;
Nysveen, Arne ;
Antonino-Daviu, Jose A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (11) :11675-11685
[6]   Performance Evaluation of Signal Processing Tools Used for Fault Detection of Hydrogenerators Operating in Noisy Environments [J].
Ehya, Hossein ;
Nysveen, Arne ;
Skreien, Tarjei N. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (04) :3654-3665
[7]   Pattern Recognition of Interturn Short Circuit Fault in a Synchronous Generator Using Magnetic Flux [J].
Ehya, Hossein ;
Nysveen, Arne .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (04) :3573-3581
[8]   Static and dynamic eccentricity fault diagnosis of large salient pole synchronous generators by means of external magnetic field [J].
Ehya, Hossein ;
Nysveen, Arne ;
Nilssen, Robert ;
Liu, Yujing .
IET ELECTRIC POWER APPLICATIONS, 2021, 15 (07) :890-902
[9]   Steady-State Calculation and Online Monitoring of Interturn Short Circuit of Field Windings in Synchronous Machines [J].
Hao, Liangliang ;
Sun, Yuguang ;
Qiu, Arui ;
Wang, Xiangheng .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (01) :128-138
[10]   Impact of Static Air-Gap Eccentricity on Thermal Responses of Stator Winding Insulation in Synchronous Generators [J].
He, Yu-Ling ;
Sun, Kai ;
Wu, Yu ;
Zhao, Hai-Sen ;
Wang, Xiao-Long ;
Gerada, Chris ;
Gerada, David .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (12) :13544-13554