Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai

被引:3
作者
Jung, Chuloh [1 ]
El Samanoudy, Gamal [2 ]
Alqassimi, Nahla [3 ]
Sherzad, Mohammed [3 ]
机构
[1] Univ Sharjah, Coll Engn, Dept Architectural Engn, Sharjah, U Arab Emirates
[2] Ajman Univ, Coll Architecture Art & Design, Dept Interior Design, Ajman, U Arab Emirates
[3] Ajman Univ, Coll Architecture Art & Design, Dept Architecture, Ajman, U Arab Emirates
关键词
indoor air quality (IAQ); formaldehyde (HCHO); volatile organic compounds (VOCs); ventilation systems; mock-up experiment; BUILDINGS; CLIMATES;
D O I
10.3389/fbuil.2023.1286053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3-0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%-50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.
引用
收藏
页数:15
相关论文
共 50 条
[31]   Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities [J].
Ben-David, Tom ;
Waring, Michael S. .
BUILDING AND ENVIRONMENT, 2016, 104 :320-336
[32]   Impact of condensate cooled air purging on indoor air quality in an air conditioned laboratory [J].
Palanisamy, Dhamodharan ;
Ayalur, Bakthavatsalam Kannappan .
BUILDING AND ENVIRONMENT, 2021, 188
[33]   Indoor air quality and the variable-air-volume bypass filtration system: Chamber experiment [J].
Moschandreas, DJ ;
Choi, SW ;
Meckler, MM .
ENVIRONMENT INTERNATIONAL, 1996, 22 (02) :149-158
[34]   Impact of bi-directional PV blind control method on lighting, heating and cooling energy consumption in mock-up rooms [J].
Hong, Seongkwan ;
Choi, Anseop ;
Sung, Minki .
ENERGY AND BUILDINGS, 2018, 176 :1-16
[35]   A rapid review of the impact of increasing airtightness on indoor air quality [J].
Kempton, Leela ;
Daly, Dan ;
Kokogiannakis, Georgios ;
Dewsbury, Mark .
JOURNAL OF BUILDING ENGINEERING, 2022, 57
[36]   Energy Modelling and Indoor Air Quality Analysis of Cooling Systems for Buildings in Hot Climates [J].
Shaikh, Zohaib ;
Chaudhry, Hassam Nasarullah .
FLUIDS, 2018, 3 (04)
[37]   Improving Indoor Air Quality in Classrooms via Wind-Induced Natural Ventilation [J].
Bayoumi, Mohannad .
MODELLING AND SIMULATION IN ENGINEERING, 2021, 2021
[38]   Computation Fluid Dynamics Modeling of Tiny House Ventilation for the Evaluation of Indoor Air Quality [J].
Hodges, Patrick ;
Anderson, Ryan ;
Mukhopadhyay, Jaya .
ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 :509-517
[39]   A Pragmatic Approach Toward Enhancing Indoor Air Quality in Urban Settings With Limited Ventilation [J].
Kataria, Abhay ;
Mishra, Jitendra K. ;
Aras, Ajit ;
Kumar, Santosh .
IEEE SENSORS JOURNAL, 2025, 25 (11) :20602-20609
[40]   Challenges in developing ventilation and indoor air quality standards: The story of ASHRAE Standard 62 [J].
Persily, Andrew .
BUILDING AND ENVIRONMENT, 2015, 91 :61-69