Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai

被引:3
作者
Jung, Chuloh [1 ]
El Samanoudy, Gamal [2 ]
Alqassimi, Nahla [3 ]
Sherzad, Mohammed [3 ]
机构
[1] Univ Sharjah, Coll Engn, Dept Architectural Engn, Sharjah, U Arab Emirates
[2] Ajman Univ, Coll Architecture Art & Design, Dept Interior Design, Ajman, U Arab Emirates
[3] Ajman Univ, Coll Architecture Art & Design, Dept Architecture, Ajman, U Arab Emirates
关键词
indoor air quality (IAQ); formaldehyde (HCHO); volatile organic compounds (VOCs); ventilation systems; mock-up experiment; BUILDINGS; CLIMATES;
D O I
10.3389/fbuil.2023.1286053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3-0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%-50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.
引用
收藏
页数:15
相关论文
共 50 条
[21]   Evaluation on four sampling schemes for assessing indoor air quality [J].
Wong, L. T. ;
Mui, K. W. .
BUILDING AND ENVIRONMENT, 2007, 42 (03) :1119-1125
[22]   The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms [J].
Stabile, Luca ;
Massimo, Angelamaria ;
Canale, Laura ;
Russi, Aldo ;
Andrade, Alexandro ;
Dell'Isola, Marco .
BUILDINGS, 2019, 9 (05)
[23]   Ventilation strategies and indoor air quality in Swedish primary school classrooms [J].
Cabovska, Blanka ;
Beko, Gabriel ;
Teli, Despoina ;
Ekberg, Lars ;
Dalenback, Jan-Olof ;
Wargocki, Pawel ;
Psomas, Theofanis ;
Langer, Sarka .
BUILDING AND ENVIRONMENT, 2022, 226
[24]   IMPROVING INDOOR AIR QUALITY USING LOCAL EXHAUST VENTILATION (LEV) [J].
Hussin, Norasikin Binti ;
Ibrahim, Dzullijah Binti ;
Ahmad, Farrah Noor Binti ;
Yahya, Nur Hayati Binti Mohd ;
Hashim, Siti Mardini Binti .
JURNAL TEKNOLOGI, 2015, 76 (06) :7-11
[25]   In search for modeling predictive control of indoor air quality and ventilation energy demand in subway station [J].
Lee, Seunchul ;
Kim, Min Jeong ;
Kim, Jeong Tai ;
Yoo, Chang Kyoo .
ENERGY AND BUILDINGS, 2015, 98 :56-65
[26]   Distributed Control of Multizone HVAC Systems Considering Indoor Air Quality [J].
Yang, Yu ;
Srinivasan, Seshadhri ;
Hu, Guoqiang ;
Spanos, Costas J. .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2021, 29 (06) :2586-2597
[27]   Mechanical Ventilation Strategies in Buildings: A Comprehensive Review of Climate Management, Indoor Air Quality, and Energy Efficiency [J].
Rashid, Farhan Lafta ;
Al-Obaidi, Mudhar A. ;
Al Maimuri, Najah M. L. ;
Ameen, Arman ;
Agyekum, Ephraim Bonah ;
Chibani, Atef ;
Kezzar, Mohamed .
BUILDINGS, 2025, 15 (14)
[28]   Indoor Air Quality at School: Ventilation Rates and It Impacts Towards Children A review [J].
Salleh, Naziah Muhamad ;
Kamaruzzaman, Syahrul Nizam ;
Sulaiman, Raha ;
Mahbob, Naziatul Syima .
ENVIRONMENTAL SCIENCE AND TECHNOLOGY, PT 2, 2011, 6 :418-422
[29]   Indoor Air Quality Monitoring Systems Based on Internet of Things: A Systematic Review [J].
Saini, Jagriti ;
Dutta, Maitreyee ;
Marques, Goncalo .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (14) :1-22
[30]   Assessing the impact of high and low occupancy on air quality inside a library [J].
Jain, Supreme ;
Goel, Anubha ;
Ola, Deepshikha ;
Addya, Asmita ;
Kabdal, Yogesh .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2025, 50 (02)